MAURY USCG vessel records Sign in
← All vessels

CHEM 701

CHEM 701 is a 2007 tank barge. The Coast Guard has recorded 15 inspections since 2007, most recently in July 2022, along with 2 deficiencies and 2 casualty investigations between 2008 and 2013.

Records from 2007 to 2022. Most recent: inspection, 27 July 2022.

Built
2007
Last inspected
27 July 2022
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

885876
Flag
UNITED STATES
—
Maury page id
psix-885876

Inspections, by type

…with no type recorded2
Years with a record 11 calendar years (2007–2022)
The 15 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Documentation record

Registered dimensions (L × B × D)200.0 ft × 35.0 ft × 12.5 ft
Registered tonnagegross 735 / net 735
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJEFFBOAT LLC · JEFFERSONVILLE, IN, UNITED STATES · built 2007
Hull materialSteel
PropulsionNot recorded
Hull shapeBox
Hull configurationMonohull
Hailing portJEFFERSONVILLE, IN
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 11 May 2026 · expires 31 May 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it735 - Simplified, Gross Ton
735 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

INTRA REGAL Towing Vessel · MISLE 153970 · 29 June 2008 · activity 3252539

Inspection history · 15

27 July 2022 Drydock Exam · COI Inspection · Internal Structural Exam · MTSA Verification · Examination of Repairs · Cargo Tank Internal
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7512874
27 June 2018 Administrative Inspection · Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6467172
19 June 2017 Cargo Tank Internal · MTSA Verification · COI Inspection · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6176916
17 May 2017 Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6148466
30 March 2016 Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 5867933
27 February 2015 MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5075771
15 June 2012 Internal Structural Exam · COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4342886
21 July 2011 Annual Inspection · Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4104262
25 February 2011 Damage Survey · Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3952704
24 February 2011 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3952360
23 August 2010 Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3833122
20 May 2009 Administrative Inspection
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3479864
29 July 2008 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3282019
29 June 2008 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3252539
27 August 2007 Deadweight Survey · Initial Certification · Cargo Tank Internal · MTSA Verification · Hull Examination · Initial Construction-Excluding Oversight · Internal Structural Exam
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3042045

Deficiency record · 2

Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 21 July 2011 Resolved
Pump Packing was leaking.
Action required: 705 - Other - as specified
Due 21 July 2011
Resolved 21 July 2011
Resolution: Repacked packing.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 25 February 2011 Resolved
Test and install fuel tank in accordance with 46 CFR 58.50-10. Conduct final inspection in presence of a marine inspector. Conduct or provide documentation of pressure test prior to installation.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 February 2011
Resolution: Witnessed satisfactory hydrostatic test and reviewed specifications from manufacturer.

Casualty record · 2

29 June 2008Routine · role: Involved in a Marine Casualty · activity 3252539
17 January 2013Routine · role: Involved in a Marine Investigation (non-casualty) · activity 4526707
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.