MAURY USCG vessel records
← All vessels

NORWEGIAN GEM

NORWEGIAN GEM is a 2007 passenger vessel (inspected). The Coast Guard has recorded 60 inspections since 2016, most recently in February 2026, along with 15 deficiencies and 2 operational controls.

Records from 2016 to 2026. Most recent: inspection, 1 February 2026.

Built
2007
Last inspected
1 February 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 1 February 2026
…with no type recorded26
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9355733
886049
Flag
BAHAMAS, THE
Maury page id
psix-886049

Documentation record

Tonnage as PSIX records it93530 - Convention (Subpart B), Gross Ton
63887 - Convention (Subpart B), Net Ton
50259 - Displacement, Ton
11059 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 60

1 February 2026 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8304732
16 December 2025 PSC A · COC-CVE Annual
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8283794
16 June 2025 COC-CVE Quarterly
Type not classified · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8156398
20 December 2024 COC-CVE Annual · PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8048880
8 September 2024 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8024119
6 September 2024 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7997803
15 August 2024 Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7987634
5 July 2024 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7953016
14 June 2024 PSC B · COC-CVE Quarterly
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7934288
10 May 2024 In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7916122
7 May 2024 Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7908193
3 May 2024 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7905983
25 December 2023 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7842323
22 December 2023 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7852724
19 December 2023 COC-CVE Annual · PSC A
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7837743
22 December 2022 COC-CVE Annual · Ballast Water Examination · PSC A
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7611267
7 February 2022 COC-CVE Quarterly
Type not classified · Sector New York · USCG Northeast District (CGD-NE) · Activity 7391714
22 December 2021 Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7371676
28 November 2021 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7358297
26 September 2021 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7320630
8 September 2021 Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7307544
7 July 2021 COC-CVE Annual · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7246491
6 July 2021 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7246857
6 April 2020 In-Service Inspection
Physical examination · USCG Southeast District (dp) · USCG Southeast District (CGD-SE) · Activity 6936035
16 March 2020 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6927509
7 January 2020 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6884033
9 November 2019 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6853625
5 November 2019 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6850729
11 October 2019 Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6832906
21 September 2019 Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6822528
20 September 2019 COC-CVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6805382
9 September 2019 Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6807268
24 August 2019 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6797182
24 August 2019 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6797206
21 August 2019 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6815638
31 July 2019 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6769350
13 July 2019 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6750409
12 July 2019 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6774236
8 July 2019 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6773849
21 June 2019 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6774242
30 May 2019 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6710984
9 April 2019 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6658758
5 April 2019 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6658178
18 March 2019 Ballast Water Examination · ISPS II Exam · COC-CVE Quarterly
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6644238
6 December 2018 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6595008
26 September 2018 Ballast Water Examination · ISPS II Exam · COC-CVE Annual
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6543842
16 September 2018 Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6543210
14 April 2018 ISPS II Exam · Ballast Water Examination · COC-CVE Quarterly
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6391385
21 November 2017 In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6311026
10 October 2017 COC-CVE Annual · ISPS II Exam · MARPOL Annex I Examination · MARPOL Annex VI Survey · Ballast Water Examination · MARPOL Annex V Examination
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6284615
12 April 2017 Ballast Water Examination · ISPS II Exam · COC-CVE Annual
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6121505
4 February 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6114637
30 December 2016 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6066752
15 October 2016 ISPS II Exam · COC-CVE Annual · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6022836
10 September 2016 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6006623
3 May 2016 In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5867919
5 April 2016 COC-CVE Quarterly · ISPS II Exam · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5846592
21 February 2016 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5819356
26 January 2016 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5803357
12 January 2016 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5796328

Deficiency record · 15

07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 16 December 2025 Resolved
The means of escape, including stairways and exits, shall be marked by lighting or photoluminescent strip indicators placed not more than 300 mm above the deck at all points of the escape route, including angles and intersections. The marking must enable passengers/crew to identify the routes of escape and readily identify the escape exits. Additionally, escape route signs and fire equipment location markings shall be of photoluminescent material or marked by lighting. . The PSCO observed a 15ft strip of low location lighting not working outside the stardust lounge on deck 7.
Action required: 10 - Deficiency Rectified
Resolved 17 December 2025
Resolution: Rectified deficiency on-the-spot.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 16 December 2025 Resolved
Each operation described in paragraph 2 of this regulation shall be fully recorded without delay in the Oil Record Book Part 1, so that all entries in the book appropriate to that operation are completed. Each completed operation shall be signed by the officer or officers in charge of the operations concerned and each completed page shall be signed by the master of ship. The PSCO observed entries for discharge overboard through the white box and not using the OWS content meter on the IOPP.
Action required: 10 - Deficiency Rectified
Resolved 17 December 2025
Resolution: Corrected deficiency on-the-spot.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 16 December 2025 Resolved
Escape doors from public spaces that are normally latched shall be fitted with a means of quick release. Such means shall consist of a door-latching mechanism incorporating a device that releases the latch upon the application of a force in the direction of escape flow. The PSCO observed the Rialta meeting room on deck 6 emergency escape door was locked blocking means of escape.
Action required: 10 - Deficiency Rectified
Resolved 17 December 2025
Resolution: Corrected deficiency on-the-spot.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 16 December 2025 Resolved
Stairway enclosures in accommodation and service spaces shall have direct access from the corridors and be of a sufficient area to prevent congestion, having in view the number of persons likely to use them in an emergency. The PSCO observed Christmas trees installed in stairway enclosures blocking means of escape.
Action required: 10 - Deficiency Rectified
Resolved 17 December 2025
Resolution: Corrected deficiency on-the-spot.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 20 December 2024 Resolved
The construction of doors and door frames in "A" class divisions, with the means of securing them when closed, shall provide resistance to fire as well as to the passage of smoke and flame equivalent to that of the bulkheads in which the doors are situated. FSD 01-5-024 and FSD 01-6-032 did not fully close.
Action required: 10 - Deficiency Rectified
Resolved 20 December 2024
Resolution: Both doors fixed on the spot.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 20 December 2024 Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. Portable extinguishers which have been discharged shall be immediately recharged or replaced with an equivalent unit. High-pressure water mist bulb in garbage cold room found cracked and no fluid.
Action required: 10 - Deficiency Rectified
Resolved 20 December 2024
Resolution: Sprinkler replaced on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 20 December 2024 Resolved
Muster and embarkation stations shall be adequately illuminated by lighting supplied from the emergency source of electrical power required by regulation II-1/42 or II-2/43. 03 lights on stbd side by lifeboat #8, #16, and MES were extinguished.
Action required: 10 - Deficiency Rectified
Resolved 20 December 2024
Resolution: Lights replaced on the spot.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 22 December 2022 Resolved
It shall be possible for each door to be opened and closed from each side of the bulkhead by one person only. While conducting a deck walk examination, USCG PSCO discovered that FSD 04-6-124 does not open more than 12 inches. (74 SOLAS 20 II-2/9.4.1.1.4) (15ac)
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 22 December 2022
Resolution: Door was adjusted and deficiency rectified prior to CG departure.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 22 December 2022 Resolved
Quick release mechanisms shall be designed and installed to the satisfaction of the Administration and, in particular not be equipped with any locking device, set screw or other arrangement that prevents the release of the latch when pressure is applied to the releasing device. Vessel removed all twist locks on emergency exit/exit doors in Le Bistro restaurant & vessel's arcade room (74 SOLAS 20 II-2/13.3.2.6.2.3) (10c)
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 22 December 2022
Resolution: Vessel corrected deficiency on the spot.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 7 February 2022 Resolved
A fixed fire detection and alarm systremns shall be so installed and arranged as to provide smoke detection and...accomodation spaces. Smoke alarm located in the "Hang Loose" bar area (port-side) was not labeled with location ID.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 13 February 2022
Resolved 9 February 2022
Resolution: Received class report indicating corrective action performed.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 7 February 2022 Resolved
Operational readiness. Passenger ships carrying more than 36 passengers shall be equippeed with an automatic sprinkler. Sprinkler head located on deck 13 next to detector 13-03-26-023 in port-side deck storage area was knocked askew.
Condition: Damaged By Earlier Event
Action required: 15 - Rectify deficiencies by next port
Due 13 February 2022
Resolved 9 February 2022
Resolution: Received class report indicating corrective action performed.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 7 February 2022 Resolved
Openings in bulkheads and decks in passenger ships. The approximate time of closure for hinged doors shall be no more than 40 seconds and no less than 10 seconds from the beginning of their movement with the ship in the upright position. Fire door 12-05-036 did not close fully.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 13 February 2022
Resolved 9 February 2022
Resolution: Received class report indicating corrective action performed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 July 2021 Resolved
Fixed fire fighting systems such as a high pressure sprinkler systems, shall include means for giving a visual and audible alarm signal automatically whenever a sprinkler comes into operation. The flow alarm for section valve 8/4 and 9/4 was not giving a visual indication showing water flow through the system. SOLAS 20 II-2/10 FSS Code Chapter 8.5.2.1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2021
Resolved 8 July 2021
Resolution: Received Class Survey Statement covering repaired section valve and images of proper alarm/indicator operation.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 20 September 2019 Resolved
Crew members shall be familiar with the arrangements of the ship as well as the location and operation of any firefighting systems and appliances that they may be called upon to use. PSCO observed crew members in three different galleys were unfamiliar with the location and proper operation of local firefighting appliances. 50ac 74 SOLAS (09) II-2/15.2.2.1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 October 2019
Resolved 11 October 2019
Resolution: Class provided documentation attesting that all personnel demonstrated good knowledge of local fire fighting appliances and systems, as well as galley’s personnel actions in case of fire in the galley, first response, and notifications.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 20 September 2019 Resolved
For determining the appropriate fire integrity standards to be applied to boundaries between adjacent spaces, such spaces are classified according to their fire risk as shown in categories (1) to (14). PSCO observed the space within FSD 09-6-043 was listed as a storage space categorized as a category 13; however, the space was being utilized as a housekeeping office. 50 ac 74 SOLAS (09) II-2/9.2.2.3.2.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 October 2019
Resolved 20 September 2019
Resolution: 10c - Space was restored to a storage room instead of an office.

Ownership record