MAURY USCG vessel records
← All vessels

SIDER BILBAO

SIDER BILBAO is a 2007 freight ship. The Coast Guard has recorded 21 inspections since 2017, most recently in October 2023, along with 17 deficiencies and 2 operational controls.

Records from 2017 to 2023. Most recent: inspection, 19 October 2023.

Built
2007
Last inspected
19 October 2023
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9338151
886117
Flag
PORTUGAL
Maury page id
psix-886117

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded3
Years with a record 7 calendar years (2017–2023)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it9177 - Convention (Subpart B), Gross Ton
4751 - Convention (Subpart B), Net Ton
18568 - Displacement, Metric Ton
14184 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 21

19 October 2023 Administrative Inspection · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7811372
19 June 2023 PSC B
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7714924
4 April 2023 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7662274
18 October 2022 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7579714
16 October 2022 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7578252
12 October 2022 Ballast Water Examination · Deficiency Check · PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7573452
8 October 2022 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7573815
15 July 2021 ISPS Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7256874
23 June 2021 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7233977
21 June 2021 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7231440
16 October 2020 PSC B · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7078305
9 October 2020 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7074455
5 October 2020 Deficiency Check · PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7071442
9 November 2019 Ballast Water Examination · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6848851
2 November 2019 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6847526
5 May 2019 Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6683769
28 September 2018 ISPS II Exam · Deficiency Check · Ballast Water Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6549389
17 September 2018 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6542045
14 September 2018 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6540792
29 August 2017 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6253790
9 June 2017 Joint Vessel Security Verification (Massena only) · ISPS II Exam
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6173511

Deficiency record · 17

07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 12 October 2022 Resolved
Bulkheads of cargo ships shall be maintained in accordance with the minimum fire integrity as prescribed in tables 9.5 and 9.6. PSCO observed unapproved cable penetrations in "A-O" fire boundary between stairwell and navigational bridge.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 October 2022
Resolved 13 October 2022
Resolution: Vessel removed cable runs and repaired openings in fire boundary. Class report/survey submitted.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Incinerator incl. operations and operating manual
Issued 12 October 2022 Resolved
Equipment shall be maintained to conform with the applicable Annex. PSCO observed the shipboard incinerator was in operable.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 October 2022
Resolved 12 October 2022
Resolution: Vessel electrician identified disconnect flame sensor. Reconnected flame sensor and the system operated and tested normally.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 October 2022 Resolved
Cables and wiring shall be installed and supported in such a manner as to avoid chafing or other damage. PSCO observed electrical cable was not fitted into the junction box properly with a stuffing tube leaving the cable unsecured.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 12 October 2022
Resolved 13 October 2022
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 16 October 2020 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO observed the rescue boat was inoperable. Specifically, the fuel line was leaking and clogged. 74SOALS(14) III/20.1 10(c)
Action required: 10 - Deficiency Rectified
Resolved 16 October 2020
Resolution: Crew changed fuel line and was able to start the rescue boat. Review of inspection records and external audit showed regular maintenance has been completed.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 5 October 2020 Resolved
07126 - Means shall be provided to control the leaks of flammable liquids. PSCO observed oil accumulation at the #1 & #2 generators, and fuel leaks at the cylinder heads, and fuel injector pumps. Fuel leaks were found at the main engine #1, #2, and #4 fuel injectors. 74 SOLAS (14)II-2/4.1.1 30ac
Action required: 30 - Ship detained
Resolved 6 October 2020
Resolution: Received class survey report
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 5 October 2020 Resolved
07123 - Fire fighting systems and appliances shall be kept readily available for immediate use. PSCO observed hyper-mist system was in manual mode. Chief Engineer could not verify when the hyper-mist system has been changed over to manual. 74 SOLAS (14) II-2/14.2.1.2 30ac
Action required: 30 - Ship detained
Resolved 6 October 2020
Resolution: Received class survey report
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 5 October 2020 Resolved
07123 - Fire detection systems and appliances shall be kept readily available for immediate use. PSCO observed smoke detector in the engine room covered with a plastic bag and unable to detect smoke in the space. 74 SOLAS (14) II-2/14.2.1.2 30ac
Action required: 30 - Ship detained
Resolved 6 October 2020
Resolution: Received class survey report
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 5 October 2020 Resolved
15106 - The company should establish procedures to ensure that the ship is maintained in accordance with the provisions of the relevant rules and regulations established by the company. Due to the objective evidence in the above deficiencies, the vessel is not in substantial compliance with relevant conventions. The COTP questions the adequacy and overall implementation of the vessel's SMS under the ISM Code. An external audit conducted by the flag or RO is recommended within 30 days to determine if this ship is operating in accordance with the ISM Code. Provide copy of completed audit report to USCG. 74 SOLAS (14) XI-1/4.1 ISM Code 10.1
Action required: 30 - Ship detained
Resolved 6 October 2020
Resolution: Received class survey report
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 October 2020 Resolved
13199 - The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed leaking sea water cooling pipe which feeds the ship's main engine and generators. 74 SOLAS (14)I/11(a) 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 October 2020
Resolution: Received class survey report
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 5 October 2020 Resolved
07126 - Means shall be provided to control the leaks of flammable liquids. PSCO observed pooled oil accumulated in nearly all drip pans for the main engine, buckets of oil around the engine room on the lower deck and at the cylinder oil measuring tank, and oil soaked lagging throughout the engine room. Oily rags were discovered around the main engine and throughout the engine room, including one oily rag holding up a light. 74 SOLAS (14) II-2/4.1.1 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 October 2020
Resolution: Received class survey report
07 - Fire Safety › N/A - No Subsystem › Jacketed high pressure lines and oil leakage alarm
Issued 5 October 2020 Resolved
07117 - The machinery, boilers, and other pressure vessels, associated piping systems and fittings shall be of design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board. PSCO observed leaking jacket water from #2, #3, and #6 cylinder. 74 SOLAS (04)II-1/26.1 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 October 2020
Resolution: Received class survey report
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 5 October 2020 Resolved
07113 - Ships shall be provided with fire pumps, fire mains, hydrants, and hoses complying with the applicable requirements of this regulation. PSCO observed inoperable fire pump and water leaking from the general service pump. 74 SOLAS (14)II-2/10.2 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 October 2020
Resolution: Received class survey report
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 5 October 2020 Resolved
07120 - Escape from machinery spaces of Category A shall have self-closing fire doors of the same fire integrity standards. The door for the emergency escape on the lower deck of the engine room was excessively corroded allowing for the passage of light throught the seals. 74 SOLAS (14) II-2/13.4.2.1 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 October 2020
Resolution: Received class survey report
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 5 October 2020 Resolved
09233 - The machinery shall be installed and protected so as to reduce to a minimum any danger to persons on board, due regard being paid to moving parts. PSCO observed missing guard from the main diesel generator No.1. 74 SOLAS (04) II-1/26.1 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 October 2020
Resolution: Received class survey report
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 October 2020 Resolved
09209 - The safety of passengers, crew, and ship from electrical hazards will be ensured. Several electrical covers were missing, including the cover for the level gauge for the sludge tank, cover for the general service pump, gauge cover for the settling tank, gauge for the HFO #2 service tank, HFO settling tank, three electrical connections in the vicinity of the main engine. 74 SOLAS (04) II-1/40.1.3 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 October 2020
Resolution: Received class survey report
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 5 October 2020 Resolved
03199 - The ring, lines and letters shall be painted white or yellow on a dark background or in black on a light background. They shall also be permanently marked on the sides of the ships to the satisfaction of the administration. The ring, lines, and letters were corroded to the point that they were no longer a contrasting color. In addition, the load line was not abaft of the the Plimsoll which is not in accordance with the vessel's ILLC. ILLC 2005/8 50ac
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 October 2020
Resolution: Received class survey report
02 - Structural Conditions › N/A - No Subsystem › Loading/Ballast condition
Issued 28 September 2018 Resolved
1220 - Freeboard marks - The ring, lines and letters shall be painted in white or yellow on a dark ground or in black on a light ground. They shall also be permanently marked on the sides of the ships to the satisfaction of the Administration. The marks shall be plainly visible and, if necessary, special arrangements shall be made for this purpose. PCPO observed severly worn markings on vessel. - ICLL (88 PROTO) Reg 8 - Action Taken 16c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 October 2018
Resolved 29 September 2018
Resolution: Vessel painted markings and sent pictures to verify.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.