MAURY USCG vessel records
← All vessels

VIKING BRASILIA

VIKING BRASILIA is a 2007 freight ship. The Coast Guard has recorded 10 inspections since 2018, most recently in May 2026, along with 2 deficiencies and 1 operational control, 1 with no removal date recorded.

Records from 2018 to 2026. Most recent: inspection, 24 May 2026.

Built
2007
Last inspected
24 May 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
1 with no removal date recorded

Identity

9368895
V7A3685
886870
Flag
MARSHALL ISLANDS
Maury page id
psix-886870

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 2016.

Inspections, by type

Years with a record 6 calendar years (2018–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it51731 - Convention (Subpart B), Gross Ton
17252 - Dead Weight, Ton
15519 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 10

24 May 2026 COE-Administrative
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8379475
23 March 2026 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8330652
27 February 2026 PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8313693
16 June 2025 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8160807
14 June 2025 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8159281
12 June 2025 PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8155490
12 November 2024 PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8033356
19 October 2020 PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7079839
3 April 2019 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6654863
6 January 2018 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6333064

Deficiency record · 2

07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 12 June 2025 Resolved
Fire-fighting system and appliances shall be kept in good working order. Vessel was issued a class report by NKK acknowledging a temporary fire main repair. Class report directs the vessel to report and replace the line if any leaking is observed. PSCO observed a leak from the fire main in the vicinity of the patch when the fire pump was energized. 74SOLAS(20)II-2/14.2.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 June 2025
Resolution: Fire main was repaired. Class and CG attended to verify.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 12 June 2025 Resolved
Fixed fire detection and fire alarm system installations shall be suitable for the nature if the space. PSCO observed all three smoke detectors in the ECR were not operable when tested. 74SOLAS(20)II-2/7.1.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 June 2025
Resolution: Fire detectors were repaired. Class and CG attended to verify.

Ownership record