Records from 1992 to 2026. Most recent: inspection, 22 July 2026.
Documentation record
Registered dimensions (L × B × D)50.7 ft × 24.1 ft × 5.4 ft
Registered tonnagegross 71 / net 48
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWALKER BOAT YEARD INC · PADUCAH, KY, UNITED STATES · built 1966
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portCATOOSA, OK
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 4 August 2026 · expires 31 July 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it71 - Regulatory (Subpart C or D), Gross Ton
48 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 29
22 July 2026
Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 8447747
5 June 2025
Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 8153534
9 September 2024
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7999211
19 April 2024
Examination of Repairs
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7898265
13 June 2023
COI Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7706486
8 February 2023
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7627904
21 June 2022
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7483973
18 May 2021
Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7201420
14 July 2020
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6984935
15 January 2020
Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6890893
28 June 2018
Deficiency Check · Initial Certification · COI Inspection · MTSA/ISPS Verification · Administrative Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6469512
30 January 2018
Administrative Inspection
Administrative · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6346556
25 June 2017
Type not recorded
No type recorded · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6204742
14 June 2001
Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 212477
14 July 1999
Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 212305
12 November 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 763060
29 May 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 83583
29 May 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 195216
6 March 1995
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 5024
17 January 1995
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 219432
13 January 1995
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 45875
20 December 1994
Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 708334
3 December 1994
Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 116060
31 May 1994
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 676133
25 May 1994
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 162518
1 February 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 676134
20 December 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 180397
20 May 1993
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 15236
22 January 1992
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 159730
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 11 October 2024
Resolved
To stop the flow of fuel in the event of a fire or break in the fuel line, a remote fuel shutoff valve must be fitted on any fuel line that supplies fuel directly to a propulsion engine or generator prime mover. The aforementioned valve must be operable outside the space where the valve is located. Remote fuel shutoff valves did not activate the shutoff valves. Ensure remote shutoff valves are fully operational prior to vessel movement.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 8 November 2024
Resolved 17 October 2024
Resolution: Replaced faulty remote fuel shutoff valves.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 11 October 2024
Resolved
All portable fire extinguishers and fire detection systems shall be inspected/tested every 12 months as prescribed in 46 CFR 142.240(a). Upon inspection, it was found that the installed fire extinguishers and fire detection system were passed the annual inspection due date. Provide documentary evidence of the annual inspection being conducted prior to vessel movement
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 8 November 2024
Resolved 17 October 2024
Resolution: Fire system serviced.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 13 June 2023
Resolved
Port and Starboard rudder post/stock was observed allowing excess water to intrude onto the deck of the vessel while maneuvering under power. Owner shall ensure the rudder port is repaired to prevent excessive water intrusion.
46CFR 140.605(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 July 2023
Resolved 10 July 2023
Resolution: Vessel owner replaced rudder stock bearing. vessel has been repaired with no water intrusion.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 8 February 2023
Resolved
Replace all flexible pipping connected to the side coolers found within the void spaces on the port and starboard sides of the vessel with hard pipping.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 February 2023
Resolved 28 February 2023
Resolution: Hard pipping installed with ball valves on all through-hull penetrations leading to the side coolers on the port and starboard sides of the vessel.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 23 June 2022
Resolved
Rudder posts were found to be leaking water during use.
Action required: 705 - Other - as specified
Resolved 28 June 2022
Resolution: Rudder posts were filled with grease to create a seal.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 23 June 2022
Resolved
Distress signals onboard were found expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2022
Resolved 28 June 2022
Resolution: New flares installed (expiring on September of 2022).
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 June 2022
Resolved
Shaft seals were observed leaking excess water.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2022
Resolved 28 June 2022
Resolution: Shaft seal packing replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 June 2022
Resolved
Lifebuoy light brackets were found missing. Lights observed hanging from the lifebouy and risked damage from colliding and rubbing against the railing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2022
Resolved 28 June 2022
Resolution: Lights arranged to no longer be at risk of destruction. New brackets ordered.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 June 2022
Resolved
Lifejackets were not of appropriate number installed onboard the vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2022
Resolved 28 June 2022
Resolution: New lifejackets with appropriate equipment and markings installed in proper amount.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 14 July 2020
Resolved
Install light on port ring life buoy
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 28 July 2020
Resolved 5 August 2020
Resolution: Installed light on port ring life buoy
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 14 July 2020
Resolved
Replace Safety Release Valve on air compressor
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 28 July 2020
Resolved 5 August 2020
Resolution: Replaced Safety Release Valve on air compressor
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 July 2020
Resolved
Store flammables in proper flame locker in Engine Room
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 28 July 2020
Resolved 5 August 2020
Resolution: Proper flame locker installed in Engine Room
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 28 June 2018
Resolved
Pressure relief valves must be tested at least twice every five years, with no more than 3 years elapsing since last test. Test in accordance with manufacturer's instructions and provide satisfactory evidence to CG inspector. 46 CFR 143.245.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 28 June 2018
Resolved 28 June 2018
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 28 June 2018
Resolved
Plexiglass cover was cracked on fire detection panel. Replace the plexiglass cover on the fire detection system on the bridge. 46 CFR 142.330.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 28 June 2018
Resolved 28 June 2018
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 28 June 2018
Resolved
All installed bilge pumps must have a check/foot valve in each bilge suction that prevents unintended backflooding through bilge piping. Install a check/foot valve in bilge suction line. 46 CFR 143.275.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 28 June 2018
Resolved 28 June 2018