MISTER LEW is a 1966 towing vessel. The Coast Guard has recorded 29 inspections since 1992, most recently in July 2026, along with 15 deficiencies and 1 casualty investigation in 2017.
Records from 1992 to 2026. Most recent: inspection, 22 July 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Registered dimensions (L × B × D)50.7 ft × 24.1 ft × 5.4 ft
Registered tonnagegross 71 / net 48
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWALKER BOAT YEARD INC · PADUCAH, KY, UNITED STATES · built 1966
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portCATOOSA, OK
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 4 August 2026 · expires 31 July 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it71 - Regulatory (Subpart C or D), Gross Ton 48 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1980 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
The Coast Guard recorded this vessel and the following in the same
inspection activity — normally a tug and the barges in its tow. A recreational or
unclassed hull in the same activity is held and not published, so it does not appear
here: these lists are a floor, not a complete manifest.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 11 October 2024Resolved
To stop the flow of fuel in the event of a fire or break in the fuel line, a remote fuel shutoff valve must be fitted on any fuel line that supplies fuel directly to a propulsion engine or generator prime mover. The aforementioned valve must be operable outside the space where the valve is located. Remote fuel shutoff valves did not activate the shutoff valves. Ensure remote shutoff valves are fully operational prior to vessel movement.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 8 November 2024
Resolved 17 October 2024
Resolution: Replaced faulty remote fuel shutoff valves.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 11 October 2024Resolved
All portable fire extinguishers and fire detection systems shall be inspected/tested every 12 months as prescribed in 46 CFR 142.240(a). Upon inspection, it was found that the installed fire extinguishers and fire detection system were passed the annual inspection due date. Provide documentary evidence of the annual inspection being conducted prior to vessel movement
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 8 November 2024
Resolved 17 October 2024
Resolution: Fire system serviced.
Port and Starboard rudder post/stock was observed allowing excess water to intrude onto the deck of the vessel while maneuvering under power. Owner shall ensure the rudder port is repaired to prevent excessive water intrusion.
46CFR 140.605(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 July 2023
Resolved 10 July 2023
Resolution: Vessel owner replaced rudder stock bearing. vessel has been repaired with no water intrusion.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 8 February 2023Resolved
Replace all flexible pipping connected to the side coolers found within the void spaces on the port and starboard sides of the vessel with hard pipping.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 February 2023
Resolved 28 February 2023
Resolution: Hard pipping installed with ball valves on all through-hull penetrations leading to the side coolers on the port and starboard sides of the vessel.
Rudder posts were found to be leaking water during use.
Action required: 705 - Other - as specified
Resolved 28 June 2022
Resolution: Rudder posts were filled with grease to create a seal.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 23 June 2022Resolved
Distress signals onboard were found expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2022
Resolved 28 June 2022
Resolution: New flares installed (expiring on September of 2022).
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 June 2022Resolved
Shaft seals were observed leaking excess water.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2022
Resolved 28 June 2022
Resolution: Shaft seal packing replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 June 2022Resolved
Lifebuoy light brackets were found missing. Lights observed hanging from the lifebouy and risked damage from colliding and rubbing against the railing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2022
Resolved 28 June 2022
Resolution: Lights arranged to no longer be at risk of destruction. New brackets ordered.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 June 2022Resolved
Lifejackets were not of appropriate number installed onboard the vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2022
Resolved 28 June 2022
Resolution: New lifejackets with appropriate equipment and markings installed in proper amount.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 14 July 2020Resolved
Install light on port ring life buoy
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 28 July 2020
Resolved 5 August 2020
Resolution: Installed light on port ring life buoy
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 14 July 2020Resolved
Replace Safety Release Valve on air compressor
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 28 July 2020
Resolved 5 August 2020
Resolution: Replaced Safety Release Valve on air compressor
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 July 2020Resolved
Store flammables in proper flame locker in Engine Room
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 28 July 2020
Resolved 5 August 2020
Resolution: Proper flame locker installed in Engine Room
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 28 June 2018Resolved
Pressure relief valves must be tested at least twice every five years, with no more than 3 years elapsing since last test. Test in accordance with manufacturer's instructions and provide satisfactory evidence to CG inspector. 46 CFR 143.245.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 28 June 2018
Resolved 28 June 2018
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 28 June 2018Resolved
Plexiglass cover was cracked on fire detection panel. Replace the plexiglass cover on the fire detection system on the bridge. 46 CFR 142.330.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 28 June 2018
Resolved 28 June 2018
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 28 June 2018Resolved
All installed bilge pumps must have a check/foot valve in each bilge suction that prevents unintended backflooding through bilge piping. Install a check/foot valve in bilge suction line. 46 CFR 143.275.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 28 June 2018
Resolved 28 June 2018
25 June 2017Routine · role: Involved in a Marine Casualty · 1 injured · activity 6204742
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.