Records from 2007 to 2026. Most recent: inspection, 12 June 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 28
12 June 2026
COI Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8394940
31 October 2025
Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8267532
28 May 2025
Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8141272
28 May 2024
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7894341
26 October 2023
Hull Examination · Administrative Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7814986
21 June 2023
Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7719987
20 September 2022
Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7557400
8 September 2022
Type not recorded
No type recorded · Station Eastport · USCG Northeast District (CGD-NE) · Activity 7554654
20 October 2021
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7357071
14 June 2021
DAPI Audit · COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7224977
13 January 2021
Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7123992
3 December 2020
Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7105736
6 November 2019
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6850890
9 July 2019
Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6742498
19 September 2018
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6536822
20 October 2017
Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6291528
22 September 2017
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6272394
7 July 2016
COI Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 5917541
13 October 2015
Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 5795356
28 September 2015
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 5232259
2 October 2014
Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 4987360
12 July 2012
Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 4376233
13 December 2011
Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 4208706
7 July 2011
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 4072708
29 November 2010
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3901722
11 December 2009
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3650135
12 December 2008
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3392676
18 September 2007
COI Inspection · Hull Examination · Construction Oversight · Plan Review "T" Boat · Simplified Stability Test
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3060601
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 28 May 2024
Resolved
O/O to obtain FCC Radio Safety Certificate.
Condition: Invalid
Action required: 705 - Other - as specified
Due 21 June 2025
Resolved 29 May 2025
Resolution: FCC Safety Certificate on vessel to expire 8 Jun 2029
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 28 June 2023
Resolved
Provide proof of enrollment in drug testing consortium.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 July 2023
Resolved 18 July 2023
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 28 June 2023
Resolved
Prove operation of starboard cabin light.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2023
Resolved 18 July 2023
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 28 June 2023
Resolved
Provide valid FCC station license.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2023
Resolved 29 June 2023
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 28 June 2023
Resolved
Prove updated tide tables, CP/Eldridge.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2023
Resolved 18 July 2023
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 June 2023
Resolved
Replace one fire bucket.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2023
Resolved 18 July 2023
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 28 June 2023
Resolved
Provide proof of fixed extinguishing system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 July 2023
Resolved 29 June 2023
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 28 June 2023
Resolved
Reposition and remount lazaret high level float switch.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2023
Resolved 18 July 2023
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 21 June 2023
Resolved
Replace broken window, starboard side bridge.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2023
Resolved 25 July 2023
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 26 September 2022
Resolved
Vessel must receive an annual inspection prior to carrying passengers for hire. Vessel did not receive its first annual inspection in 2022 as a result of being hauled out earlier than expected due to a passing Hurricane.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 May 2023
Resolved 28 June 2023
Resolution: Inspection completed.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 21 June 2021
Resolved
Prove operation of horn.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 July 2021
Resolved 12 July 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 June 2021
Resolved
Provide line on ring buoy waterlight. Vessel restricted to daytime only operations until corrected.
Action required: 705 - Other - as specified
Due 19 July 2021
Resolved 26 August 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 June 2021
Resolved
Provide 1 additional adlult sized type 1 PFD. Vessel restricted to carrying 29 total persons until corrected.
Action required: 705 - Other - as specified
Due 19 July 2021
Resolved 14 August 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 June 2021
Resolved
Provide Alcohol test kits.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 July 2021
Resolved 24 August 2021
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 21 June 2021
Resolved
Prove operation of stern light. Vessel restricted to daytime only until corrected.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 July 2021
Resolved 24 August 2021
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 21 June 2021
Resolved
Prove operation of high level alarm lights for V-berth and cabin.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 July 2021
Resolved 14 July 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 21 June 2021
Resolved
Provide FCC Safety Certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2021
Resolved 4 June 2024
Resolution: Closed and reissued.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 21 June 2021
Resolved
Provide details on drug testing consortium/covered employees list.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 July 2021
Resolved 12 July 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 13 January 2021
Resolved
Conduct annual/COI inspection with CG Marine Inspector prior to carrying more than 6 passengers for hire. Vessel status in "Inactive" until corrected.
Action required: 705 - Other - as specified
Resolved 21 June 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 3 December 2019
Resolved
Repair cracked window prior to 2021 operating season.
Action required: 705 - Other - as specified
Due 7 January 2021
Resolved 21 June 2021
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 19 September 2018
Resolved
Proved operation of vessel sound producing device.
Action required: 705 - Other - as specified
Due 1 May 2019
Resolved 9 July 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 19 September 2018
Resolved
Prove operation of mid-body bilge pump.
Action required: 705 - Other - as specified
Due 1 May 2019
Resolved 9 July 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 19 September 2018
Resolved
Prove operation of aft-steering void bilge pump.
Action required: 705 - Other - as specified
Due 1 May 2019
Resolved 9 July 2019
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 19 September 2018
Resolved
Interface MMIS number into DSC VHF Radio.
Action required: 705 - Other - as specified
Due 1 May 2019
Resolved 9 July 2019
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 19 September 2018
Resolved
Provide non-expired battery in ring buoy float light.
Action required: 705 - Other - as specified
Due 1 May 2019
Resolved 9 July 2019
Accommodation/Occupational Safety › Ventilation › General
Issued 20 October 2017
Resolved
Large areas of what appears to be black mold was found in mid-body void causing an unsanitary condition. Remove mold from mid-body void.
Action required: 705 - Other - as specified
Due 30 June 2018
Resolved 9 July 2019
Electrical › Electrical Distribution System (service) › Junction Box
Issued 20 October 2017
Resolved
Bilge pump and High Water Alarm connections are not made in enclosures. This leads to moisture and accidental damage to connections causing conductors to break affecting a vital system. Make all connections in enclosures and protect from bilge water.
Action required: 705 - Other - as specified
Due 30 June 2018
Resolved 9 July 2019
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 7 July 2016
Resolved
Prove operation of stern light.
Action required: 705 - Other - as specified
Due 7 August 2016
Resolved 4 August 2016
Resolution: O/O advised that the old fixture was corroded. a new fixture was purcahsed and installed.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 7 July 2016
Resolved
Provide FCC Safety Certificate.
Action required: 705 - Other - as specified
Due 7 August 2016
Resolved 4 August 2016
Resolution: FCC Safety Cert. has been issued.
Lifesaving › Hand Flares › Expired
Issued 2 October 2014
Resolved
Provide 3 distress signals.
Due 9 October 2014
Resolved 2 October 2014
Resolution: Corrected during the exam.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 2 October 2014
Resolved
Replace expired contents of first aid kit.
Action required: 705 - Other - as specified
Due 1 May 2015
Resolved 28 September 2015
Resolution: First aid kit medical supplies current.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 2 October 2014
Resolved
Provide Coast Pilot and Light Lists for operating area.
Action required: 705 - Other - as specified
Due 28 September 2015
Resolved 28 September 2015
Resolution: Vessel has copy of coast pilot, light list on vessel.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 2 October 2014
Resolved
Provide FCC Safety Certificate.
Action required: 705 - Other - as specified
Due 28 September 2015
Resolved 28 September 2015
Resolution: FCC Safety Certificate is on vessel to expire on 20 Sept 2020.
Engineering › Steering Gear System › Rudder Bearing
Issued 2 October 2014
Resolved
Repair rudder bearing plate; leaking where bedded to hull.
Action required: 705 - Other - as specified
Due 28 September 2015
Resolved 28 September 2015
Resolution: Rudder bearing base plate bedding replaced.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 7 July 2011
Resolved
Post Certificate of Inspection.
Action required: 705 - Other - as specified
Due 13 August 2011
Resolved 18 August 2011
Documentation › Certificates/Documents › Stability Letter
Issued 7 July 2011
Resolved
Post stability Letter.
Action required: 705 - Other - as specified
Due 13 August 2011
Resolved 18 August 2011
Documentation › Logs/Records › Drug Test Records
Issued 7 July 2011
Resolved
Provide and post an EAP phone number.
Action required: 705 - Other - as specified
Due 13 August 2011
Resolved 18 August 2011
Operations/Management › Drills/Instruction › Abandon Ship
Issued 7 July 2011
Resolved
Post emergency instructions.
Action required: 705 - Other - as specified
Due 13 August 2011
Resolved 18 August 2011
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 7 July 2011
Resolved
Provide corrected nav chart, tide tables, and Rules of the Road.
Action required: 705 - Other - as specified
Due 13 August 2011
Resolved 18 August 2011
Documentation › Logs/Records › Logbook (official)
Issued 7 July 2011
Resolved
Provide a 2011 ships log.
Action required: 705 - Other - as specified
Due 13 August 2011
Resolved 18 August 2011
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 7 July 2011
Resolved
Reduce deck rail spacing down to 4 inches.
Action required: 705 - Other - as specified
Due 13 August 2011
Resolved 18 August 2011
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 7 July 2011
Resolved
Mark llife jacket stowage locations.
Action required: 705 - Other - as specified
Due 13 August 2011
Resolved 18 August 2011
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 7 July 2011
Resolved
Provide 2 portable lights.
Action required: 705 - Other - as specified
Due 13 August 2011
Resolved 18 August 2011
Documentation › Certificates/Documents › FCC SSL
Issued 7 July 2011
Resolved
Provide and post an FCC Radio Station Certificate.
Action required: 705 - Other - as specified
Due 13 August 2011
Resolved 9 September 2011
Documentation › Certificates/Documents › FCC SSL
Issued 7 July 2011
Resolved
Provide and post a Radio Safety Certificate.
Action required: 705 - Other - as specified
Due 13 August 2011
Resolved 9 September 2011
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 29 November 2010
Resolved
MISSING ALCOHOL TEST KIT, PROVIDE AS REQUIRED.
Due 29 December 2010
Resolved 16 December 2010
Resolution: Received fax verification.
Lifesaving › Hand Flares › Expired
Issued 29 November 2010
Resolved
02 HAND HELD FLARES EXPIRED, PROVIDE AS NEW.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 December 2010
Resolution: Received fax verification
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 29 November 2010
Resolved
FIRST AID KIT CONTAINE EXPIRED EYE WASH, REPLACE AS NEW.
Due 29 December 2010
Resolved 16 December 2010
Resolution: Received fax verification.
Engineering › Bilge Water Management System › Interface Detector
Issued 29 November 2010
Resolved
FORWARD HIGH LEVEL BILGE AUDIBLE ALARM INOPERABLE, REPAIR OR REPLACE AS NEW.
Due 29 December 2010
Resolved 14 February 2011
Resolution: Attended vessel to verify operation of high water alarm.
Engineering › Fuel Oil Service System › Tank
Issued 12 December 2008
Resolved
The ground for the single fuel tank could not be located. Owner must provide location of fuel tank ground.
Condition: Design Flaw
Due 13 February 2009
Resolved 12 March 2009
Fire Fighting › Portable CO2 Fire Extinguisher › Approval
Issued 12 December 2008
Resolved
Owner must provide proof of anual servicing of portable fire extinguishers aboard the vessel.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 February 2009
Resolved 12 March 2009
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 12 December 2008
Resolved
Owner must provide at least two battery operated lanterns.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 March 2009
Construction/Loadline › Structures › Transverse Bulkhead
Issued 12 December 2008
Resolved
Owner must ensure that watertight bulkheads located at positions 12.6' and 19.4' are watertight.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 March 2009
Electrical › Lighting (service) › Lighting Fixture
Issued 12 December 2008
Resolved
Owner must ensure that masthead light is operable.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 March 2009