Records from 1992 to 2026. Most recent: inspection, 4 March 2026.
Everything above is free. The detail below — the inspection history, the deficiency record, the tow units and the documentation record — is Professional, $39 a month. Sign in.
Documentation record
Registered dimensions (L × B × D)58.2 ft × 21.0 ft × 6.6 ft
Registered tonnagegross 84 / net 57
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBARBOUR METAL BOAT WORKS · ST LOUIS, MO, UNITED STATES · built 1966
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portPARKERSBURG, WV
Trade endorsementsCoastwise, Bowaters
DocumentationValid · issued 7 May 2026 · expires 31 May 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it84 - Regulatory (Subpart C or D), Gross Ton
57 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page
20 inspections, each with its date, unit and type; 20 deficiencies with the resolution recorded against each; 6 vessels inspected with it, by name and date; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
Plans
Sign in
Maury does not score, rate or grade vessels, at any price.
Inspection history · 20
4 March 2026
Annual Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 8319833
5 March 2025
Annual Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 8088490
23 January 2024
Damage Survey · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 7853567
13 December 2023
Examination of Repairs · Administrative Inspection · Internal Structural Exam · Drydock Exam · COI Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 7839251
7 March 2023
Annual Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 7646771
29 March 2022
Annual Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 7420979
18 March 2021
Annual Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 7157171
12 December 2019
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6896841
14 December 2018
Initial Certification · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6598165
14 December 2018
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6598832
23 March 2016
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 5839485
2 December 2015
Industry Initiated Exam
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 5777242
1 June 2015
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 5144743
29 November 2012
Industry Initiated Exam
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 4493379
7 December 2011
DAPI Audit
Administrative · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 4221467
6 July 2005
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2419364
22 July 2004
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 2141815
29 December 2003
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1973654
2 June 1994
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 26550
24 May 1992
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 19740
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 14 December 2018
Resolved
Provide proof of enrollment of all crew members in consortium drug and alcohol program.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 January 2019
Resolved 26 July 2019
Resolution: Vessel representative provided proof of enrollment for all crew.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 14 December 2018
Resolved
Ensure vessel's station bill reflects crew duties.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 January 2019
Resolved 26 July 2019
Resolution: Updated muster list posted in pilot house.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 14 December 2018
Resolved
Enroll in EPA vessel general permit program.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 January 2019
Resolved 26 July 2019
Resolution: SVGP applies to vessels over 79 ft in length. Deficiency cleared.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 14 December 2018
Resolved
Ensure charts are updated and publications on board.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 January 2019
Resolved 26 July 2019
Resolution: Charts and publications updated. Deficiency cleared.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 December 2018
Resolved
Label all life jackets with vessel's name.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 January 2019
Resolved 26 July 2019
Resolution: Life jackets labeled PAUL D.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 14 December 2018
Resolved
Record details of emergency drills and training.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 January 2019
Resolved 26 July 2019
Resolution: Reviewed drills logged for fire and abandon ship.
10 - Safety of Navigation › N/A - No Subsystem › Voyage or passage plan
Issued 14 December 2018
Resolved
Conduct navigation assessment prior to getting underway.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 January 2019
Resolved 26 July 2019
Resolution: Reviewed start up daily check sheet and navigation assessment.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 December 2018
Resolved
Provide approved floating waterlight to avoid daylight only operations.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 January 2019
Resolved 26 July 2019
Resolution: Master installed two waterlights on board; only one is required.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 December 2018
Resolved
Provide Type V works vests or seek special consideration.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 January 2019
Resolved 26 July 2019
Resolution: Crew was using Type V vests on board.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 December 2018
Resolved
Label and stow extra lifejackets on board.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 January 2019
Resolved 26 July 2019
Resolution: Life jackets stowage was labeled in the pilot house and in the galley.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 14 December 2018
Resolved
Ensure all navigational lights are not obscured.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 January 2019
Resolved 26 July 2019
Resolution: Stern navigation lights were not obscured by the new smaller flag installed.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 14 December 2018
Resolved
Ensure B-V extinguisher is secured.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 January 2019
Resolved 26 July 2019
Resolution: B-V was secured with a ratchet strap.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 14 December 2018
Resolved
Secure flammable material locker and monitor corrosion on deck.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 January 2019
Resolved 26 July 2019
Resolution: Flammable material locker was secured to the bulkhead and a rubber mat was placed under it to prevent corrosion.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 14 December 2018
Resolved
Remove excess oil in bilge creating a fire hazard.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 January 2019
Resolved 26 July 2019
Resolution: Excess bilge oil removed.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 14 December 2018
Resolved
Prove sufficient water discharge capacity of fire pump.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 January 2019
Resolved 26 July 2019
Resolution: Witnessed operation of Honda 160 portable pump with adequate pressure.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 December 2018
Resolved
Ensure all portable fire extinguisher brackets are marine grade and correct fit for extinguisher bottle.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 January 2019
Resolved 26 July 2019
Resolution: New bracket installed for extinguisher outside engine room.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 14 December 2018
Resolved
Prove proper operation of heat sensor in machinery space in accordance with manufacturer's testing procedure.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 January 2019
Resolved 26 July 2019
Resolution: Witnessed operation of the heat sensor which triggered alarm on fire control panel in pilot house. Master then operates the general alarm from the bridge as the audible and visual alarm in the engine room.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 14 December 2018
Resolved
Prove proper operation of fire detection panel in accordance with manufacturer's testing procedures.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 January 2019
Resolved 26 July 2019
Resolution: Witnessed operation of the fire control panel in normal mode and through backup batteries.
09 - Working and Living Conditions › 092 - Working Conditions › Ropes and wires
Issued 14 December 2018
Resolved
Replace all corroded safety chain clips with corrosion resistant linkages.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 20 December 2018
Resolved 26 July 2019
Resolution: Corroded chain clips replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 14 December 2018
Resolved
Mark all watertight hatches.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 January 2019
Resolved 26 July 2019
Resolution: Water tight hatches properly marked.