MAURY USCG vessel records Sign in
← All vessels

THERESE DANOS

THERESE DANOS is a 2007 offshore supply vessel. The Coast Guard has recorded 25 inspections since 2007, most recently in August 2026, along with 8 deficiencies and 1 casualty investigation in 2015.

Records from 2007 to 2026. Most recent: inspection, 11 August 2026.

Built
2007
Last inspected
11 August 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9097135 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDH3296
891117
Flag
UNITED STATES
367606280
Maury page id
psix-891117

Inspections, by type

…with no type recorded2
Years with a record 16 calendar years (2007–2026)
The 25 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Registered dimensions (L × B × D)130.6 ft × 36.0 ft × 12.0 ft
Registered tonnagegross 88 / net 60
ITC dimensions (L × B × D)130.6 ft × 36.0 ft × 12.0 ft
ITC tonnagegross 447 / net 134
BuilderMASTER BOAT BUILDERS INC · CODEN, AL, UNITED STATES · built 2007
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 1 May 2026 · expires 31 May 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it88 - Regulatory (Subpart C or D), Gross Ton
447 - Convention (Subpart B), Gross Ton
60 - Regulatory (Subpart C or D), Net Ton
134 - Convention (Subpart B), Net Ton
576 - Dead Weight, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDH3296MMSI 367606280 · active · compulsorily equipped · granted 13 February 2024, expires 19 February 2034
WDD7860MMSI 367192310 · cancelled · compulsorily equipped · granted 6 June 2007, cancelled 27 January 2014 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 25

11 August 2026 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8461939
29 July 2025 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8197311
15 July 2025 Cargo Tank Internal · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8186231
12 August 2024 Periodic Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7980496
25 September 2023 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7780135
27 July 2022 Hull Examination · Internal Structural Exam · COI Inspection · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7517270
23 September 2021 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7323108
20 November 2020 Periodic Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7099329
2 November 2020 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7088378
21 July 2020 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7012065
10 October 2019 MTSA Verification · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6809544
27 September 2018 Annual Inspection · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6533816
24 July 2017 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6218931
17 July 2017 Examination of Repairs · Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6212241
5 April 2017 Type not recorded
No type recorded · Station Lake Charles · USCG Heartland District (CGD-H) · Activity 6118896
22 September 2016 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5989894
22 July 2015 Periodic Inspection · Deficiency Check · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5192178
12 January 2010 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3662517
27 April 2009 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3462266
22 April 2009 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3458147
10 October 2008 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3435655
8 October 2008 Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3340583
30 July 2007 Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3012653
12 July 2007 Plan Review (Other than "T")
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2992564
10 July 2007 Security Plan Review - VSP · Initial Certification · Plan Review (Other than "T") · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2991514

Deficiency record · 8

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 September 2023 Resolved
Piping shall not be run over or in the vicinity of switchboards or other electrical equipment if avoidable. When such leads are necessary, welded joints only shall be used and provision shall be made to prevent leakage from damaging the equipment. There was an overhead potable water pipe leaking just aft of the port generator. Vessel shall complete permanent repairs to the leaking potable water pipe to resolve the leakage. 46CFR128.220(d) / 46CFR56.50-1(d).
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 October 2023
Resolution: POC provided objective evidence in the form of photos to show permanent repair/replacement of the leaking piping.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 25 September 2023 Resolved
Electrical equipment on a vessel must be designed, installed, and maintained to provide services necessary for safety under normal and emergency conditions. The starboard generator was displaying an error/fault message that could not be cleared or rectified during the inspection. Vessel shall rectify error/fault message and ensure generator is fully operational. 46CFR129.200(a).
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 October 2023
Resolution: POC provided objective evidence in the form of photos to show stbd generator error/fault message was cleared and generator readout was showing no fault/errors.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 24 July 2017 Resolved
Vessel replaced previously approved anchor and removed anchor winch, provide proof that newly installed anchor is sufficient to safely anchor the vessel IAW 46 CFR 184.300. Or replace currently installed anchor with previously approved anchor.
Action required: 705 - Other - as specified
Due 24 August 2017
Resolved 25 July 2017
Resolution: Previously approved anchor was re-installed on the vessel.
Lifesaving › Lifebuoys › Serviceable
Issued 22 July 2015 Resolved
Two life bouys were found to be unservicable one, had a cut in it and the other one had wasted grablines.
Due 22 July 2015
Resolved 22 July 2015
Resolution: Replaced on site.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 22 July 2015 Resolved
Line was 10-12 on all life bouys with self igniting lights instead of require 3-6 ft.
Due 22 July 2015
Resolved 22 July 2015
Resolution: Corrected on site.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 22 July 2015 Resolved
Life saving checks were not being conducted using a checklists as required by 46CFR131.565(a)
Due 23 July 2015
Resolved 23 July 2015
Resolution: Company rep said that they were in the process of developing checklists for the company''s vessels to use. Note added to Misle to ensure records are available for next years inspection.
Documentation › Markings/Placards › Garbage Placard
Issued 22 July 2015 Resolved
Vessel did not have a current MARPOL V Placard.
Due 22 July 2015
Resolved 22 July 2015
Resolution: Vessel wen tto store and purchased new one.
Construction/Loadline › Structures › Door
Issued 22 July 2015 Resolved
Emergency escape hatch from engine room was not water tight and could not be open from engine room side.
Due 22 July 2015
Resolved 22 July 2015
Resolution: Vessel''s Crew adjusted dogs.

Casualty record · 1

25 January 2015Routine · role: Sighted in Area · serious marine incident, as classified · 1 dead · activity 5059972
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.