Records from 2012 to 2026. Most recent: inspection, 25 March 2026.
Inspection history · 27
25 March 2026
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8331865
9 March 2026
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8322808
16 January 2026
In-Service Inspection · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8297280
18 April 2025
Plan Review (Other than "T")
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8105333
8 April 2025
Periodic Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8090368
18 April 2024
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7898126
18 October 2023
Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7813622
14 September 2023
Internal Structural Exam · Cargo Tank Internal · Deficiency Check · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7773659
15 August 2023
Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7768642
8 August 2023
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7763115
1 February 2023
Type not recorded
No type recorded · Station Galveston · USCG Heartland District (CGD-H) · Activity 7630938
5 October 2022
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7571938
31 March 2022
COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7419978
13 October 2021
Drydock Exam · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7343929
19 May 2021
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7218316
15 April 2021
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7241220
1 March 2021
COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7147891
22 May 2020
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6957904
12 April 2019
Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6661051
1 April 2019
Internal Structural Exam · Hull Examination · Examination of Repairs · Administrative Inspection · Cargo Tank Internal
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6653378
17 March 2019
Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6644543
7 May 2018
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6414496
21 April 2018
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6399816
22 February 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6359637
4 April 2017
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6101996
22 September 2016
Examination of Repairs · Administrative Inspection · Hull Examination · Internal Structural Exam · Cargo Tank Internal
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6006534
25 February 2016
Deficiency Check · COI Inspection · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5821667
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 9 March 2026
Resolved
Shutoff valves. Shutoff valves must be installed in the fuel supply lines, one as close to each tank as practicable, and one as close to each fuel pump as practicable. Shut off valve on aft deck for fuel tanks was wasted and may detach from bulkhead. Repair valve and valve housing.
46 CFR 56.50-75(b)(4)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 March 2026
Resolution: Attended vessel cleared associated def see inspection narrative.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 March 2026
Resolved
Electrical installations on vessels must ensure the protection of the crew and vessel from electrical hazards. A-Frame lighting wiring had salt water entry into the plug on the main deck. Repair prior to using A-Frame Lighting. Vessel is restricted from conducting night time operations unless adequate lighting is provided to the aft deck.
46 CFR 111.01-1
Action required: 705 - Other - as specified
Resolved 13 March 2026
Resolution: Attended vessel cleared associated def see inspection narrative.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 March 2026
Resolved
Except as provided by § 132.100(b) of this subpart, each vessel must be equipped with one self-priming power-driven fire pump capable of delivering a single stream of water from the highest hydrant, through the hose and nozzle at a Pitot-tube pressure of at least 345 kPa.
Vessels fire pump for fire monitor was leaking at the
packing gland.
46 CFR 132.120
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 March 2026
Resolution: Vessel repaired fire monitor pump. See narrative.
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 8 April 2025
Resolved
After loading but before departure, and at other times necessary to assure the safety of the vessel, the master shall verify that the vessel complies with requirements in its trim and stability book, stability letter, certificate of inspection and load line certificate, whichever apply, and then enter a statement of the verification in the logbook. Vsl missed their annual survey on the International Load line Certificate.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 9 April 2025
Resolution: ABS conducted annual survey, sat.
01 - Certificates & Documentation › 012 - Crew Certificates › Cert for personnel on survival craft & rescue boat
Issued 18 April 2024
Resolved
Provide crew list for additional personel. (offshore workers)
For total persons onboard.
705 C Prior to operations
Action required: 705 - Other - as specified
Resolved 19 April 2024
Resolution: List provided
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 18 April 2024
Resolved
Provide inspection/service paper work for addotional life raft (6 persons) and inspect final stowage location.
Action required: 705 - Other - as specified
Resolved 19 April 2024
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 18 April 2024
Resolved
Capt stateroom #1 needs immersion suit signage.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 April 2024
Resolution: Cleared on the spot
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 18 April 2024
Resolved
Main deck 4 man birthing port side, life jacket & immersion suits locker blocked by stores, must remove.
Action required: 705 - Other - as specified
Resolved 18 April 2024
Resolution: Stores removed
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 18 April 2024
Resolved
Update log book to reflect service of vessel. Multi service vessel must log type of service currently working.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 April 2024
Resolution: Cleared on the spot.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Loading instrument
Issued 18 April 2024
Resolved
Provide copy of crane cert from recent inspection.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 April 2024
Resolution: Corrected on the spot
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 18 April 2024
Resolved
PAM fwd escape needs a stair/platform to prevent personel haz on deck, stepping on top of temp MSD tank.
Action required: 705 - Other - as specified
Resolved 19 April 2024
Resolution: Fabicated landing and stairs.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 18 April 2024
Resolved
PAM installed fire detection not wired/and/or tested due to the need of a wire to the host vessel, provide and test with CGMI.
Action required: 705 - Other - as specified
Resolved 19 April 2024
09 - Working and Living Conditions › 091 - Living Conditions › Ventilation (Accommodation)
Issued 18 April 2024
Resolved
PAM's fwd ventilation does not close, must fix and prove proper operation with CGMI
Action required: 705 - Other - as specified
Resolved 19 April 2024
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 18 April 2024
Resolved
Provide servicing report for additional immersion suits.(4)
Action required: 705 - Other - as specified
Resolved 19 April 2024
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 April 2024
Resolved
Provide/prove PAM instal bolts are per plan. ASTM 325 3/4 x 2.5"
Action required: 705 - Other - as specified
Resolved 19 April 2024
Resolution: Bolts paper work provided.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Procedure for inspection, reporting and correcting unsafe conditions and for investigating a
Issued 18 April 2024
Resolved
Provide to CGMI an approved PAM and Electrical install plan.
Action required: 705 - Other - as specified
Resolved 26 April 2024
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 18 April 2024
Resolved
Wire to temp MSD needs a better arraingement to prevent electrical haz and do not use zip ties.
Action required: 705 - Other - as specified
Resolved 19 April 2024
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 18 April 2024
Resolved
Provide a battery charger in aft engine room. IWO bulkhd
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 April 2024
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 18 April 2024
Resolved
Wires must terminate in an enclosure, port side engine room escape.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 April 2024
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 18 April 2024
Resolved
Light fixture must have cable gland for wires.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 April 2024
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 18 April 2024
Resolved
Provide one additional fire extiguisher for aft protable gen set.
Action required: 705 - Other - as specified
Resolved 19 April 2024
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 18 April 2024
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Resolved 19 April 2024
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 15 August 2023
Resolved
In the event of alterations involving the safety of the vessel, the applicable plans shall be submitted for approval covering the proposed work except as modified by § 91.45–1. Vessel's fire control plan is not approved.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 September 2023
Resolved 18 October 2023
Resolution: Stamped FCP Approved.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 August 2023
Resolved
Electrical installations on vessels must ensure protection of passengers, crew, other persons, and the vessel from electrical hazards. Engine room distribution panel is missing blanks and/or circuit breakers in the panel, creating an electrical hazard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 September 2023
Resolved 14 September 2023
Resolution: Blanks installed.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 15 August 2023
Resolved
Indication of the rudder angle must be provided both at the main steering station in the pilothouse and in the steering-gear compartment. The rudder-angle indicator must be independent of control systems for steering gear.
Rudder angle indicator on the port rudder is not accurate. Indication of the rudder angle must be provided both at the main steering station in the pilothouse and in the steering gear compartment.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 September 2023
Resolved 6 October 2023
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 August 2023
Resolved
If your voyage time is less than 96 hours then you must submit an NOA before departure but at least 24 hours before arriving at the port or place of destination. Vessel was found arrived in Provport 08AUG2023 without submitting an ANOA. Vessel was contacted and ANOA was submitted after arrival.
33CFR160.212(a)
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 8 August 2023
Resolved 15 August 2023
Resolution: Vessel was contacted and ANOA was submitted after arrival.
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 24 May 2022
Resolved
The ring, lines and letters shall be painted in white or yellow on a dark ground or in black on a light ground. They shall also be permanently marked. Paint load line and ensure letters are permanently marked prior to crossing the boundary line.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 27 May 2022
Resolution: Provided picture
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 24 May 2022
Resolved
Cylinders shall be so mounted as to be readily accessible. CO2 room was being used for storage and not accessible. Configure shelving in CO2 room to prevent equipment from impeding the access to the CO2 bottles and local controls.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2022
Resolved 16 August 2022
Resolution: Owner/operator is no longer using room for storage.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 May 2022
Resolved
Each lifebuoy must be capable of being rapidly cast loose. Relocate port and starboard lifebuoys on main deck from underneath the stairs so they are readily accessible.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2022
Resolved 27 May 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 May 2022
Resolved
Each lifebuoy must be marked in block capital letters with the name of the vessel and the name of the port. Clearly mark the port aft lifebuoy on the main deck.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2022
Resolved 27 May 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 May 2022
Resolved
Each vessel must carry lifebuoys approved under approval series 160.150. Replace retro on aft deck lifebuoys.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2022
Resolved 27 May 2022
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 March 2021
Resolved
THIS SUBCHAPTER IS APPLICABLE TO ALL U.S. FLAG VESSELS
INDICATED IN COLUMN 4 OF TABLE 2.01-7(a). VESSEL HAS BEEN OPERATING AS A LIGHTERING SUPPORT VESSEL, FENDERING FOR STS OPERATIONS. VESSEL IS CERTIFICATED UNDER 46 CFR SUBCHAPTER "L" AND THEREFORE CANNOT CONDUCT SUCH OPERATIONS WITHOUT BEING CERTIFICATED UNDER 46 CFR SUBCHAPTER "I". VESSEL IS GRANTED 90 DAYS TO OBTAIN CERTIFICATION UNDER 46 CFR SUBCHAPTER "I" TO SATISFACTION OF ATTENDING USCG MARINE INSPECTOR.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 June 2021
Resolved 24 May 2022
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 17 March 2019
Resolved
46CFR58.25-10
(b)The main steering gear and rudder stock must be-
(1)Of adequate strength for and capable of steering the vessel at maximum ahead service speed, which must be demonstrated to the satisfaction of the cognizant Officer in Charge, Marine Inspection;
(2)Capable of moving the rudder from 35 degrees on either side to 35 degrees on the other with the vessel at its deepest loadline draft and running at maximum ahead speed, and from 35 degrees on either side to 30 degrees on the other in not more than 28 seconds under the same conditions.
While in transit offshore, steering gear/system became inoperable (lost rudder) and M/V JOSEPHINE K MILLER returned to the AET dock via assist T/V JUPITER. Must install new rudder and conduct sea trials with USCG attending MI prior to being placed back in service.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 May 2019
Resolved 12 April 2019
Resolution: Observed poper operation of new rudder installation.
Electrical › Lighting (emergency) › Lighting Branch Circuit
Issued 25 February 2016
Resolved
Vessel must have adequate emergency lighting fitted along line of escape to main deck. Both 6 person berthing spaces have no emergency lighting illuminating thr emergency hatch scuttles.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 March 2016
Resolved 26 February 2016
Resolution: Vessel rewired adequate lighting for emrgency egrees from both 6 person staterooms to the satisfaction of the attending marine inspector.