MAURY USCG vessel records
← All vessels

UFLY II

UFLY II is a 2007 passenger vessel (inspected). The Coast Guard has recorded 11 inspections since 2016, most recently in November 2023, along with 28 deficiencies — 1 with no resolution recorded — and 1 operational control.

Records from 2016 to 2023. Most recent: inspection, 8 November 2023.

Built
2007
Last inspected
8 November 2023
Documentation
Expired · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 8 November 2023
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2016–2023)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDI4371
892984
Flag
UNITED STATES
Maury page id
psix-892984

Documentation record

Registered dimensions (L × B × D)31.0 ft × 10.5 ft × 6.0 ft
Registered tonnagegross 13 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCOMMERCIAL WATER SPORTS INC · CAPE MAY COURT HOUSE, NJ, UNITED STATES · built 2007
Hull materialFRP (Fiberglass)
PropulsionDiesel Outdrive
Hull shapeShip
Hull configurationMonohull
Hailing portCORAL GABLES, FL
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 19 June 2007
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it13 - Displacement, Ton
13 - Simplified, Gross Ton
10 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

11 inspections, each with its date, unit and type; 28 deficiencies with the resolution recorded against each; 1 operational control with the dates imposed and removed; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 11

8 November 2023 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7822161
25 January 2023 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7626879
10 August 2021 COI Inspection · Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7272503
18 August 2020 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7036199
24 June 2019 Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6723681
24 April 2019 Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6669105
27 June 2018 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6454964
14 June 2017 Annual Inspection · Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6175489
28 February 2017 DAPI Audit · In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6096065
11 July 2016 COI Inspection · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 5936586
6 July 2016 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5931844

Deficiency record · 28

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 25 January 2023 No resolution recorded
To maintain a valid Certificate of Inspection, you must complete your annual inspection within the periods specified in 176.500(b)(1) [annual inspection within 3 months before or after each anniversary date] and your Certificate of Inspection must be endorsed. Vessel is outside of three month window for Inspection and is not permitted to operate until annual inspection has been completed.
Action required: 701 - Prior to carriage of passengers/cargo
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 April 2019 Resolved
The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. The port side fuel shut off valve is inoperable from outside the space. Repair or replace port side fuel shut off valve. 46 CFR 182.455(b)(4)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 April 2019
Resolution: Shut off valve fixed and is fully operable from operating station.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 24 April 2019 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level. Both bilge high level alarms are not indicating a visual and audible alarm when bilge high level alarm is activated. Repair or replace high level alarms. 46 CFR 182.530(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 April 2019
Resolution: High water bilge alarms tested and operable
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 24 April 2019 Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have a light to indicate discharge at the operating station. The visual indicator at the operating station for the pre-engineered fixed gas fire extinguishing system (fireboy) indicator light is inoperable. Repair or replace fireboy indicator. 46 CFR 181.420(b)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 April 2019
Resolution: Indicator light is operable.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 April 2019 Resolved
A space containing diesel machinery must be fitted with at least two ducts to furnish natural or powered supply and exhaust ventilation. The ventilation fan in the machinery space is not mounted properly to the provide bracket and is hanging by the electrical power wires for the fan. Properly mount ventilation fan in the machinery space. 46 CFR 182.465(c)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 April 2019
Resolution: Engine room blower is properly mounted and electrical wires are properly fitted.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 24 April 2019 Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. Vessel was unable to provide any logs for abandon ship, man overboard drills, or training. Provide a logged record of drills and training conducted. 46 CFR 185.520(f)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 April 2019
Resolution: Vessel and company developed new tracking system for all drills, logs, and safety briefs. Forms kept on board the vessel
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 24 April 2019 Resolved
Fire fighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. Vessel was unable to provide any logs for fire fighting drills or training. Provide a logged record of drills and training conducted. 46 CFR 185.524(d)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 April 2019
Resolution: Vessel and company developed new tracking system for all drills, logs, and safety briefs. Forms kept on board the vessel
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 24 April 2019 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date:(1) Charts of large enough scale to make safe navigation possible;(2) U.S. Coast Pilot or similar publication;(3) Coast Guard Light List; (4) Tide tables; and (5) Current tables, or a river current publication issued by the U.S. Army Corps of Engineers or a river authority.(b) Extracts from the publications listed above for the areas to be transited may be provided instead of the complete publication. Vessels charts and pubs are all out of date and require replacement with current updated charts and pubs for the area the vessel operates. 46 CFR 184.420(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 April 2019
Resolution: New charts and publications put on board
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 April 2019 Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure and have either:(1) A pressure type connector on each conductor; (2) A solder lug on each conductor;(3) A splice made with a pressure type connector to a flexible lead or conductor; or (4) A splice that is soldered, brazed, or welded to a flexible lead or conductor. Wiring to trim pump and machinery space ventilation fan are improperly installed. Install proper connections for wiring to trim pump and ventilation fan.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 April 2019
Resolution: Electrical installations for trim pump and machinery spaces found to be satisfactory.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 April 2019 Resolved
Batteries must be mounted in trays lined with, or constructed of, a material that is resistant to damage by the electrolyte. Starboard battery is sitting next to battery tray. Properly install starboard battery into battery tray. 46 CFR 183.350(e)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 April 2019
Resolution: battery properly mounted in tray and electrical was found to be installed correctly.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 April 2019 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Battery charger wiring is partially connected with positive end hanging loosely. Properly secure or remove battery charger wiring. 46 CFR 183.200(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 April 2019
Resolution: Battery charging wire connected properly
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 24 April 2019 Resolved
Each battery used in an item of lifesaving equipment must be replaced during the annual inspection if the expiration date of the battery has passed. Floating water light battery has surpassed its expiration date. Replace battery for floating water light. 46 CFR 185.726(e)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 April 2019
Resolution: Life buoy fully replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 April 2019 Resolved
In addition, a number of child size life jackets equal to at least 10% of the number of persons permitted on board must be provided, or such greater number as necessary to provide a life jacket for each person being carried that is smaller than the lower size limit of the adult life jackets provided to meet this section. The 02 required life jackets are wasted. Replace 02 child size life jackets. 46 CFR 180.71(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 April 2019
Resolution: vessel bought all new type I life jackets for adults and children.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 April 2019 Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Child size life jackets are stowed with adult size life jackets. Label location for child size life jackets and separate them from adult size life jackets. 46 CFR 180.78(a)(5)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 April 2019
Resolution: Life jackets are stowed separately. Adult life jackets are stored in bags in forward compartment
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 April 2019 Resolved
Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018 or other standard specified by the Commandant. All life jackets retroreflective tape is wasted and unservicable. Replace retroreflective tape on all life jackets. 46 CFR 185.604(h)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 April 2019
Resolution: vessel bought all new type I life jackets for adults and children.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 April 2019 Resolved
A vessel of more than 7.9 meters (26 feet) in length, but not more than 19.8 meters (65 feet), must carry a minimum of one life buoy of not less than 610 millimeters (24 inches) in diameter. Ring life buoy is wasted. Replace ring life buoy with serviceable buoy. 46 CFR 180.70(a)(2)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 April 2019
Resolution: brand new life buoy on board
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 April 2019 Resolved
A vessel not required to have a power driven fire pump by §181.300 must have at least three 9.5 liter (2.5 gallon) buckets. Vessel is missing one 2.5 gallon fire bucket. Provide one more 2.5 gallon fire bucket.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 April 2019
Resolution: 3 2.5 gallon fire buckets are on board
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 24 April 2019 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. First aid kit is water logged and expired. Replace with serviceable first aid kit. 46 CFR 184.710
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 April 2019
Resolution: New first aid kit on board
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 24 April 2019 Resolved
Portable watertight containers for distress flares and smoke signals shall be of a bright color, and containers shall be clearly marked in legible contrasting letters at least 12.7 millimeters (0.5 inches) high: “DISTRESS SIGNALS”. Container for distress signals is not properly labeled. Label container "DISTRESS SIGNALS". 46 CFR 185.614
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 April 2019
Resolution: distress signals container is labeled properly.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 29 June 2017 Resolved
AS APPROPRIATE FOR INTENDED VOYAGE VESSEL MUST CARRY ADEQUATE AND UP-TO-DATE CHARTS AND PUBLICATIONS. PROVIDE ALL REQUIRED CHARTS AND PUBLICATIONS AND KEEP ONBOARD VESSEL. 46 CFR 184.420.
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 July 2017
Resolved 13 July 2017
Resolution: PROVIDED ALL REQUIRED CHARTS AND PUBLICATIONS.
Documentation › Certificates/Documents › FCC SSL
Issued 29 June 2017 Resolved
PROVIDE FCC STATION LICENSE. 47 CFR 80.
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 July 2017
Resolved 13 July 2017
Resolution: PROVIDED VALID FCC STATION LICENSE.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 28 June 2017 Resolved
PROVIDE TECH REPORT PROVING PROPER OPERATION OF FIRE BOY SYSTEM.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 June 2017
Resolved 29 June 2017
Resolution: PROVIDED TECH REPORT PROVING PROPER OPERATION OF FIRE BOY SYSTEM.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 11 July 2016 Resolved
Ensure valid Certificate of Documentation is on board vessel prior to operation
Action required: 705 - Other - as specified
Due 11 July 2016
Resolved 12 July 2016
Documentation › Certificates/Documents › FCC SSL
Issued 11 July 2016 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Resolved 12 July 2016
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 11 July 2016 Resolved
Install vessel name on ring buoy & new battery in water light.
Action required: 705 - Other - as specified
Due 11 August 2016
Resolved 12 July 2016
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 11 July 2016 Resolved
Ensure operation of all-around white light prior to operation after sunset.
Due 11 August 2016
Resolved 10 August 2016
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 11 July 2016 Resolved
Provide on board required nautical publications & charts.
Action required: 705 - Other - as specified
Due 11 August 2016
Resolved 12 July 2016
Documentation › Certificates/Documents › Certificate of Inspection
Issued 6 July 2016 Resolved
Your vessel did not undergo an annual inspection within the 3 months before or after your COI anniversary date. Your COI is invalid until an satisfactory inspection has been conducted and your COI is endorsed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 July 2016
Resolution: MSD Lake Worth conducted annual inspection and issued amended COI. See MISLE activity 5936586.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.