Records from 2017 to 2023. Most recent: inspection, 7 January 2023.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Documentation record
Tonnage as PSIX records it42887 - Convention (Subpart B), Gross Ton
42887 - Regulatory (Subpart C or D), Gross Ton
27547 - Convention (Subpart B), Net Ton
27547 - Regulatory (Subpart C or D), Net Ton
82790 - Dead Weight, Metric Ton
93793 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page
7 inspections, each with its date, unit and type; 7 deficiencies with the resolution recorded against each; the documentation record, as PSIX holds it. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
Plans
Sign in
Maury does not score, rate or grade vessels, at any price.
Inspection history · 7
7 January 2023
PSC B
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7611765
22 April 2022
PSC B · Administrative Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7435999
7 December 2019
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6861945
12 November 2019
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6847885
22 February 2018
Administrative Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6359472
4 January 2018
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6329011
3 January 2017
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6060674
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 November 2019
Resolved
Spaces containing flammable liquid shall be protected by a fixed fire suppression system. PSCO observed five drums of fuel/diesel mixture in the deck store which had no fixed fire suppression system. 74 SOLAS (a) 2004 Cons II-2/10.6.3
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 November 2019
Resolution: Received, reviewed and accepted proper documentation from BIS Services LLC stating the deficiency was rectified by removing the oil drums.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 November 2019
Resolved
No electrical equipment shall be installed in any space where flammable mixtures are liable to collect in compartments assigned principally to accumulator batteries, in paint lockers or similar spaces. PSCO observed the explosion proof housing in the paint store with multiple cracks to the housing. 74 SOLAS (a) 2004 Cons II-1/45.10
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 November 2019
Resolution: Received, reviewed and accepted class report from NKK stating the deficiency was rectified. Crew replaced the light housing with a new one.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 12 November 2019
Resolved
On board training in the use of the ship's lifesaving appliances, including survival craft equipment, and in the use of the ship's fire-extinguishing appliances shall be given as soon as possible but not later than two weeks after a crew member joins the ship. PSCO observed 03 crew members training records missing the training. A corrective action plan is required from company with concurrence with certificate issuing agency. 74 SOLAS (a) 2014 cons III/19.4.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 November 2019
Resolved 15 November 2019
Resolution: Received, reviewed and accepted class report from NK stating the deficiency was rectified. A corrective action plan was formed, training was conducted and an internal company audit is required to ensure implementation was conducted.
14 - Pollution Prevention › 147 - Anti-Fouling › Other (AFS)
Issued 12 November 2019
Resolved
Removing fouling organisms from the vessel's hull, piping and tanks on a regular basis... PSCO observed significant hull growth on the stern of the vessel. Vessel is prohibIted from cleaning hull while in USA waters. 33CFR151.2050(f)
Action required: 15 - Rectify deficiencies by next port
Resolved 7 December 2019
Resolution: Attended vessel to examine visible portions of hull and reviewed receipts from contracted cleaning company.
Fire Fighting › Structural - Main Vertical Zones › General
Issued 4 January 2018
Resolved
0750 - Fire Prevention - "A" class divisions are those divisions formed by bulkheads and decks which comply with the following criteria: They are so constructed as to be capable of preventing the passage of smoke and flame to the end of the one-hour standard fire test. Penetrations in the electrical cable trunks were missing fire stop material. 74 SOLAS (09) II-2/3.2.4 - 50ac
Action required: 705 - Other - as specified
Due 3 February 2018
Resolved 22 February 2018
Resolution: Class report attests to repair and proper operation of equipment.
Engineering › Steering Gear System › Pump
Issued 4 January 2018
Resolved
2050 - Operations of Machinery - All the steering gear components and the rudder stock shall be of sound and reliable construction to the satisfaction of the administration. During local steering gear test, number one steering gear pump drifted 05 degrees to starboard. 74 SOLAS (04) II-1/29.2.1 - 40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 4 February 2018
Resolved 22 February 2018
Resolution: Class report attests to repair and proper operation of equipment.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 4 January 2018
Resolved
0750 - Fire Prevention - Stairways which penetrate only a single deck shall be protected at a minimum at one level by at least "B-0" class divisions and self closing doors. Class "A" doors in vertical zone and galley did not self close as required. 74 SOLAS (09) II-2/9.2.3.4.1 - 10c
Action required: 705 - Other - as specified
Resolved 4 January 2018
Resolution: Crew members onboard made repairs to self closing doors to the satisfaction of the attending Coast Guard Port State Control Officer.