MAURY USCG vessel records
← All vessels

SILVER DRAGON

SILVER DRAGON is a 2006 freight ship. The Coast Guard has recorded 2 inspections in 2018, along with 1 deficiency — 1 with no resolution recorded — and 1 operational control.

Records in 2018. Most recent: inspection, 10 January 2018.

Built
2006
Last inspected
10 January 2018
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 10 January 2018
…past their stated due date1
Operational controls None recorded without a removal date
Years with a record 1 calendar year (2018)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9364447
893148
Flag
HONG KONG
Maury page id
psix-893148

Documentation record

Tonnage as PSIX records it40492 - Convention (Subpart B), Gross Ton
25884 - Convention (Subpart B), Net Ton
74748 - Dead Weight, Metric Ton
87337 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 2

10 January 2018 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6331095
5 January 2018 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6333324

Deficiency record · 1

Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 10 January 2018 No resolution recorded
9900 - Other(clearly nonhazardous) - Each loading transfer pipe system must not leak under static liquid pressure at least 1.5 times the maximum allowable working pressure. PSCO observed that vessel tested fuel/oil transfer piping system to 1.5 times the maximum allowable working pressure using air instead of a liquid. Vessel must conduct test using liquid prior to bunkering in the United States. 33 CFR 156.170(c) c
Action required: 703 - Prior to bunkering operations
Due 10 January 2018 — due date passed with no resolution recorded

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.