MAURY USCG vessel records
← All vessels

PELICAN STATE

PELICAN STATE is a 2009 tank ship. The Coast Guard has recorded 31 inspections since 2016, most recently in March 2026, along with 11 deficiencies, 1 operational control and 4 casualty investigations between 2010 and 2022.

Records from 2010 to 2026. Most recent: inspection, 7 March 2026.

Built
2009
Last inspected
7 March 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 7 March 2026
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9408102
WDE4433
894026
Flag
UNITED STATES
Maury page id
psix-894026

Documentation record

Registered dimensions (L × B × D)576.1 ft × 105.6 ft × 62.3 ft
Registered tonnagegross 29,527 / net 12,859
ITC dimensions (L × B × D)576.1 ft × 105.6 ft × 62.3 ft
ITC tonnagegross 29,527 / net 12,859
BuilderNATIONAL STEEL AND SHIPBUILDING COMPANY · SAN DIEGO, CA, UNITED STATES · built 2009
Hull materialSteel
PropulsionDiesel Direct
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portWILMINGTON, DE
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 21 May 2026 · expires 30 June 2027
Service, as the file records itTank Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it29527 - Convention (Subpart B), Gross Ton
12859 - Convention (Subpart B), Net Ton
48599 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 31

7 March 2026 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8321419
18 January 2026 Deficiency Check · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8297838
12 August 2025 Annual Inspection · ACP Annual Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8208429
2 June 2025 TPO Audit
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8149853
2 December 2024 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8042257
7 November 2024 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8031971
7 August 2024 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7976305
30 July 2024 Damage Survey · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7970577
1 July 2024 Re-Inspection · ACP COI Oversight · COI Inspection · MTSA/ISPS Verification
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7941884
17 March 2024 Bulk Liquid Transfer Monitor
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7880516
7 November 2023 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7821550
11 September 2023 MTSA/ISPS Verification · Annual Inspection · ACP Annual Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7775614
28 November 2022 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7600352
24 November 2022 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7599229
1 September 2022 Annual Inspection · ACP Annual Oversight · MTSA/ISPS Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7547994
15 August 2022 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7534220
10 August 2022 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7529979
18 April 2022 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7433272
22 March 2022 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7417082
4 March 2022 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7405787
4 February 2022 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7391075
6 January 2022 ACP Annual Oversight · Annual Inspection · MTSA/ISPS Verification
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7376883
14 December 2020 In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7116875
16 June 2020 ACP Annual Oversight · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6980256
13 June 2019 Re-Inspection · ACP Drydock Oversight · MTSA/ISPS Verification · ACP COI Oversight
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6706511
27 November 2018 Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6587555
7 August 2018 Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6503446
27 July 2018 ACP Annual Oversight · MTSA/ISPS Verification · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6491270
20 July 2018 Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6490582
1 August 2017 MTSA/ISPS Verification · Annual Inspection · ACP Annual Oversight
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6223684
20 July 2016 MTSA/ISPS Verification · ACP Annual Oversight
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5947263

Deficiency record · 11

11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 21 August 2025 Resolved
-Chemical tankers and gas carriers carrying cargos emitting toxic vapors and gases shall carry…lifeboats with a self-contained air support system complying with the requirements of section 4.8 of the code. MI found leak down test to fail and self-contained air system on #2 lifeboat did not maintain air pressure when testing. 74 SOLAS (2020) III/1.6
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2025
Resolved 22 August 2025
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 21 August 2025 Resolved
-Ships of all types shall be subdivided into spaces by thermal and structural divisions having regard to the fire risk of spaces. MI found roll down waiter fire door in galley did not have current service report. 74 SOLAS (2004) II-2/2.1
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2025
Resolved 22 August 2025
02 - Structural Conditions › N/A - No Subsystem › Asbestos containing materials
Issued 7 November 2024 Resolved
To discharge ballast water into waters of the United States, the master, owner, operator, agent, or person in charge of a vessel subject to § 151.2025 of this subpart must either ensure that the ballast water meets the ballast water discharge standard as defined in § 151.2030(a), use an AMS as described in § 151.2025(a)(3) or ballast exclusively with water from a U.S. public water system, as described in § 151.2025(a)(2), according to the schedule in paragraph (b) of this section. Vessel was given a one time waiver to discharge ballast water at Chevron berth 3 Pascagoula, MS utilizing the IMO mode. Ensure all ballast water tanks are cleaned of all sediments that are prohibiting the proper functioning of the ballast water treatment system and provide proof of proper operation of the ballast water treatment system prior to ballasting operations, to the satisfaction of the vessels ACP RO (ABS).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 8 November 2024
Resolution: Vessel submitted video evidence of BWTS in proper working order as weel as statement from teh captain attesting as to such.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 22 March 2022 Resolved
Piping systems for ships must be designed, constructed, and inspected in accordance with ASME b31.1. Vessel had crack in the main hydraulic line for the cargo pumps. Complete repairs satisfactory to vessel's class society (ABS). Vessel is restricted from cargo operations that utilize the affected hydraulic system until a class report is provided to our office at [email withheld].
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 March 2022
Resolved 23 March 2022
Resolution: Vessel provided class report attesting to satisfactory repairs.
11 - Life Saving Appliances › N/A - No Subsystem › Evaluation, testing and approval
Issued 6 January 2022 Resolved
Lifesaving appliances and arrangements shall be approved by the Administration. Multiple PFDs were found in service that are approved for domestic routes, but not approved for international routes and service as required. 74 SOLAS (20) III/4.1
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 January 2022
Resolution: Accepted as a condition of Class by report number 5098946.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 6 January 2022 Resolved
Structural fire protection, including fire-resisting divisions, and protection of openings and penetrations in these division shall be kept in good order so as to ensure their required performance if a fire occurs. Fire boundary penetrations in the deck and bulkheads of the navigation bridge electrical equipment room have mixed and disturbed fire stop material. All were found to have mismatched systems using a mix of concrete fire stop material and putty fire stop material in each penetration which is not an approved installation. 74 SOLAS (09) II-2/14.2.1.1.1
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 January 2022
Resolution: Accepted as a condition of Class by report number 5098946.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 6 January 2022 Resolved
Each survival craft shall be stowed fully equipped as required. The inventory for both life boats had expired first aid kits and anti-seasickness medicine. 74 SOLAS (20) III/13.1.4 LSA IV/4.4.8
Action required: 10 - Deficiency Rectified
Resolved 6 January 2022
Resolution: New, approved first aid kits and anti-seasickness medicine was provided for lifeboats' inventories.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 6 January 2022 Resolved
Structural fire protection, including fire-resisting divisions, and protection of openings and penetrations in these division shall be kept in good order so as to ensure their required performance if a fire occurs. Three self-closing doors in the stairtower between the navigation bridge and upper deck would not latch closed when released. 74 SOLAS (09) II-2/14.2.1.1.1
Action required: 10 - Deficiency Rectified
Resolved 6 January 2022
Resolution: The stairtower fire doors were adjusted and verified to close and latch correctly.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 6 January 2022 Resolved
No person may operate or cause the operation of a vessel unless the vessel has the marine charts, publications, and equipment as required by 33 CFR parts 164.33 through 164.41. All of the vessel's nautical publications were out of date.
Action required: 10 - Deficiency Rectified
Resolved 6 January 2022
Resolution: Vessel provided up to date nautical publications as required.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 6 January 2022 Resolved
Each vessel must carry a Bridge-to-Bridge radio certificate with a valid endorsement while subject to the Bridge-to-Bridge Act. The bridge-to-bridge certificate was endorsed with an incorrect call sign. 47 CFR 80.1005
Action required: 10 - Deficiency Rectified
Resolved 6 January 2022
Resolution: Vessel was able to obtain a valid, endorsed bridge-to-bridge certificate with the correct call sign included.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 6 January 2022 Resolved
The Oil Record Book Part 1 shall be completed on each occasion whenever bunkering of fuel or bulk lubricating oil takes place in the ship. Bunkering of fuel for the machinery operation was not recorded in the ORB Part 1 as required. MARPOL Annex I/17.2.5
Action required: 10 - Deficiency Rectified
Resolved 6 January 2022
Resolution: The vessel's Chief Engineer added the required entry for inspection.

Casualty record · 4

31 May 2010Routine · role: Involved in a Marine Casualty · activity 3757503
21 August 2010Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3834377
27 November 2018Routine · role: Involved in a Marine Casualty · activity 6587555
28 November 2022Routine · role: Involved in a Marine Casualty · activity 7600352
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.