← All vessels
PS QUEEN
PS QUEEN is a 2006 tank ship. The Coast Guard has recorded 20 inspections since 2007, most recently in August 2023, along with 14 deficiencies — 2 with no resolution recorded — and 6 operational controls.
Records from 2007 to 2023. Most recent: inspection, 12 August 2023.
- Built
- 2006
- Last inspected
- 12 August 2023
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 14 recorded · 2 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9358319 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
3EHL3
894093
Flag
HONG KONG
—
Maury page id
psix-894093
Inspections, by type
…with no type recorded7
…past their stated due date2
Years with a record
11 calendar years (2007–2023)
The 20 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it30092 - Convention (Subpart B), Gross Ton
61315 - Displacement, Metric Ton
13602 - Convention (Subpart B), Net Ton
51218 - Dead Weight, Metric Ton
61315 - Displacement, Metric Ton
13602 - Convention (Subpart B), Net Ton
51218 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 20
12 August 2023
PSC B · COC-CHEM & TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7759103
8 August 2023
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7763252
6 August 2023
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7761338
5 October 2022
PSC B · COC-CHEM & TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7565340
7 March 2021
COC-TVE Renew · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7151288
7 March 2021
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7151672
24 July 2019
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6803554
30 March 2019
ISPS II Exam · COC-CHEM & TVE Annual · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6652380
25 March 2019
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6648706
8 February 2018
Ballast Water Examination · Administrative Inspection · COC-CHEM & TVE Renew · ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6349724
22 May 2017
ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6152074
6 January 2017
Administrative Inspection · ISPS II Exam · COC-CHEM & TVE Annual · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6063402
17 January 2016
ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5794017
8 June 2014
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4891194
30 May 2014
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4874671
9 September 2010
COC-CHEM Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3841106
23 November 2008
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3368183
22 November 2008
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3367768
23 June 2008
ISPS II Exam · Ballast Water Examination · COC-CHEM Annual
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3245574
19 June 2007
PII Safety Exam · COC-CHEM Renew · ISPS II Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2960873
Deficiency record · 14
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 August 2023
No resolution recorded
Where cables which are installed in hazardous areas introduce the risk of fire or explosion in the event of an electrical fault in such areas special precautions against such risks shall be taken to the satisfaction of the admistration. PSCO observed a corroded hole in the cable trunk servicing from the house to the focsle on the starboard side just aft of the manifold. Require permanent repairs conducted to the satisfaction of certificate issuing authority and survey of integrity of electrical system on cargo block prior to the carriage of flammable/ combustable cargoes. 74 SOLAS II-1/45.5.4
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 5 October 2022
Resolved
For tankers of 20,000 tonnes deadweight and upwards constructed on or after 01 July 2002 but before 01 January 2016, the protection of the cargo tanks shall be achieved by a fixed inert gas system. PSCO observed inoperable IGG system in accordance with the requirements of the Fire Safety Systems Code. Upon expansion, PSCO identified that vessel discharged cargo on 28MAY22 without utilization of IG. Vessel is restricted from cargo operations requiring IG.
SOLAS 74(a) 2020 cons. II-2/4.5.5.1.1
Action Taken: ac
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 5 October 2022
No resolution recorded
The company should establish procedures to ensure the ship is maintained in conformity with the relevant rules and regulations and any additional requirements which may be established by the company. PSCO identified that vessel conducted cargo discharge operations on 28MAY22 without utilization of IG. No documentation was provided to show that vessel met equivalent standards. Internal safety audit and corrective action plan required by certificate issuing authority withint 90 days.
SOLAS 74(a) 2020 cons. IX/3.1 ISM Code 10
Action Taken: bc
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 5 October 2022
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO identified lifeboat's propeller interfering when maneuvering rudder to starboard resulting in clearance interference with corte nozzle.
SOLAS 74(a) 2020 cons. III/20.2
Action Taken: 17ac
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 October 2022
Resolved
The machinery, boilers and other pressure vessels, associated piping system and fitting shall be of a design and construction adequate for the service for which they are intended. PSCO observed HPU alarm leak indicator on cargo control panel. Require clarification from certificate issuing authority to the continuing acceptance prior to cargo operations.
SOLAS 74(a) 2020 cons. II-1/26.1
Action Taken: ac
14 - Pollution Prevention › 146 - MARPOL Annex VI › Incinerator incl. operations and operating manual
Issued 5 October 2022
Resolved
Except as provided in subparagraph 6.2 of this paragraph, each incinerator on a ship constructed on or after 1 January 2000...shall meet the requirements contained in appendix IV to this Annex. Each incinerator subject to this subparagraph shall be approved by the Administration. Request clarification as to operational readiness and continuing acceptance from certificate issuing authority for incinerator.
MARPOL (2017 cons.) Annex VI/16.6.1
Action Taken: ac
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 7 March 2021
Resolved
Each self propelled ship must have a shower and eyewash fountain that operates at all times. PSCO discovered multiple leaks on fresh water supply line which prevented the operation of shower and eyewash fountain. Some of the flanges were loose, other areas of pipes had wastage.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 30 March 2019
Resolved
Each cargo ship shall have one or more totally enclosed lifeboats complying with the requirements of section 4.6 of the code. Every totally enclosed lifeboat shall be provided with a rigid watertight enclosure which completely encloses the lifeboat including hatches which can be closed to make the lifeboat watertight. Port side lifeboat access hatch is not watertight. Additionally, all three hatches on both lifeboats were replaced since last survey and have not been observed by class.
74 SOLAS (2014 CONS) III/ 31.1.1.1
LSA Code 4.6.2.2
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 30 March 2019
Resolved
Doors fitted in boundary bulkheads of machinery spaces of category A shall be reasonably gastight and self closing. "A-60" door from engine changing room to engine room on upper deck has a broken door handle preventing the door from sealing properly.
74SOLAS (2004 CONS) II-2/4.2.1
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 30 March 2019
Resolved
Doors required to be self closing shall not be fitted with hold back hooks. "A-0" door to foam room and fire control station is held open with a piece of plastic banding. Also "B-15" door from engine changing room to upper deck passageway is held open with a wire.
SOLAS 74 (2004 CONS) II-2/ 4.2.2
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 30 March 2019
Resolved
Cabin doors in B class divisions shall be of self closing type. Deck changing room door and gymnasium door are missing the self closing device.
74 SOLAS (2004 CONS) II-2/ 4.1.2.2
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 30 March 2019
Resolved
Drills as far as practicable shall be conducted as if they were an actual emergency. The required equipment, specifically the lifeline and flashlight were not brought to the fire muster station. Additionally, the crew did not bring enough length of fire house, leaving the fire team approximately 20 feet from the affected space. The fire fighter was not able to properly don the SCBA and mask, allowing air to escape and draining an entire SCBA bottle before they even reached the fire. Fire fighters did not properly access the affected space. One fire fighter took off his glove and put it on the door to the space.
74SOLAS (2014) III/ 19.3.1
Operations/Management › Vessel Safety Management › Master's Responsiblity/Authority
Issued 19 June 2007
Resolved
Master did not appear to fully implement SMS with regards to cargo operations. PSCO's initially tested 4 of 12 cargo tanks - 2 had O2 content >13% and 2 had O2 content >14%, despite fact that vessel SMS requires tanks to be inerted w/ <8%. Additionally, steps to lower O2 level did not correspond with vessel's posted procedures. ISM cert. issuing authority must attest to proper SMS implementation.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 19 June 2007
Resolved
Doors leading into galley (Class A boundary) fitted with mechanical hold backs. FCP specifies A-60 doors, but doesn't specify self-closing.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.