MAURY USCG vessel records Sign in
← All vessels

GO PURSUIT

GO PURSUIT is a 2007 industrial vessel. The Coast Guard has recorded 44 inspections since 2007, most recently in April 2026, along with 22 deficiencies, 1 operational control and 5 casualty investigations between 2009 and 2024.

Records from 2007 to 2026. Most recent: inspection, 27 April 2026.

Built
2007
Last inspected
27 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9458884 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDH6498
894298
Flag
UNITED STATES
367191410
Maury page id
psix-894298

Inspections, by type

…with no type recorded7
Years with a record 17 calendar years (2007–2026)
The 44 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.

Documentation record

Registered dimensions (L × B × D)150.4 ft × 36.0 ft × 11.5 ft
Registered tonnagegross 83 / net 56
ITC dimensions (L × B × D)150.4 ft × 36.0 ft × 11.5 ft
ITC tonnagegross 499 / net 192
BuilderC & C BOATS WORKS LLC · BELLE CHASSE, LA, UNITED STATES · built 2007
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 7 August 2026 · expires 30 September 2027
Service, as the file records itIndustrial Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it499 - Convention (Subpart B), Gross Ton
456 - Displacement, Gross Ton
488 - Dead Weight, Gross Ton
83 - Regulatory (Subpart C or D), Gross Ton
192 - Convention (Subpart B), Net Ton
56 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDH6498MMSI 367191410 · active · compulsorily equipped · granted 20 September 2024, expires 29 August 2034
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

SOUTHERN SPIRIT Passenger (Uninspected) · MISLE 727322 · 3 February 2009 · activity 3411655

Inspection history · 44

27 April 2026 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8356675
18 March 2026 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8328638
27 January 2026 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8302137
14 January 2026 In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8296617
8 January 2026 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8292446
24 November 2025 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8267710
23 September 2024 Internal Structural Exam · COI Inspection · Drydock Exam · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8007792
7 May 2024 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7908936
7 May 2024 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7910074
19 December 2023 Administrative Inspection · In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7841590
18 January 2022 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7381800
13 January 2022 Administrative Inspection · Drydock Exam · Cargo Tank Internal · COI Inspection · Internal Structural Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7379916
16 April 2021 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7176668
8 April 2021 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7172591
15 March 2021 Annual Inspection · Administrative Inspection · In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7156324
13 April 2020 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6940182
20 May 2019 MTSA/ISPS Verification · MARPOL Annex I Examination · Annual Inspection · MARPOL Annex VI Survey · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6688336
26 April 2019 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6671086
12 April 2019 Administrative Inspection · Drydock Exam · Cargo Tank Internal · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6683319
9 December 2018 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6594632
9 December 2018 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6607010
27 July 2018 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6497549
10 July 2018 DAPI Audit · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6473932
4 October 2017 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6281377
3 May 2017 Damage Survey · Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6138024
2 May 2017 Damage Survey
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6136963
2 May 2017 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6138042
11 April 2017 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6122313
8 March 2017 Drydock Exam · COI Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6102118
24 February 2016 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5820741
6 October 2014 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4998357
11 August 2014 Administrative Inspection · Internal Structural Exam · Cargo Tank Internal · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4948111
28 May 2014 Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4871181
20 September 2011 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4149416
29 January 2011 Examination of Repairs
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3936609
29 January 2011 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3937392
19 October 2010 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3887026
5 October 2010 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3896512
3 February 2009 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3411655
3 February 2009 Damage Survey
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3411833
12 September 2008 Annual Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3323429
22 August 2008 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3368445
22 October 2007 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3084474
12 June 2007 Cargo Tank Internal · MTSA Verification · Construction Oversight · Administrative Inspection · Inclining Experiment · Plan Review (Other than "T") · Initial Certification · Hull Examination · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2959599

Deficiency record · 22

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 8 January 2026 Resolved
Certificates of inspection may be revoked or suspended by the Coast Guard where such process is authorized by law. This may occur if the vessel does not meet the requirements of law or regulations in this chapter or if there is a failure to maintain the safety requirements requisite to the issuance of a certificate of inspection. Vessel must recieve a satifactory inspection prior to operating commercially with new operator
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 January 2026
Resolved 14 January 2026
Resolution: Completed in service inspection and witnessed drills. All sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Tonnage certificate
Issued 13 January 2022 Resolved
Vessel has additional PAMS installed on the aft deck, which are portable enclosed spaces/temporary deck equipment, and therefore subject to inclusion in tonnage. Vessel must get readmeasured, and provide updated Tonnage Certificate to the USCG.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 February 2022
Resolved 23 February 2022
Resolution: Vessel provided new Tonnage Certificate from ABS
08 - Alarms › N/A - No Subsystem › General alarm
Issued 13 January 2022 Resolved
Vessel has PAMS installed, in which the General Alarm cannot be heard. Provide a general alarm or acceptable alternative, to ensure emergency notification of personnel in these spaces. Personnel must not be carried in these spaces until rectified.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 22 February 2022
Resolution: Company provided an acceptable administrative change to their emergency notification procedures.
01 - Certificates & Documentation › 013 - Documents › Fire control plan - all
Issued 13 January 2022 Resolved
Fire and Safety Plan does not reflect the installation of a 3rd, smaller Portable Module on the aft deck. Update the Fire Control Plan with this module and its associated required equipment.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 March 2022
Resolved 22 February 2022
Resolution: FSP change was provided by o/o. Since vessel is currently uninspected, this def is moot.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 13 January 2022 Resolved
The hold back latch on the port side engine room escape hatch did not securely hold back the hatch when opened, creating an unsafe conditon with the hatch in the open position.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 March 2022
Resolved 17 February 2022
Resolution: Vessel rep provided a picture of the functioning holdback latch.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 March 2021 Resolved
Renew Flexible Jacket Water Coupling on BMDE's or prove satisfactory condition. Flexible Couplings on BMDE's were found cracked and showing signs of deterioration.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 April 2021
Resolved 16 April 2021
Resolution: Flex Couplings replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 19 March 2021 Resolved
Renew Extinguished lamps on the main switchboard. At time of inspection various (4) lamps were extinguished and spares were not readily available.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2021
Resolved 25 March 2021
Resolution: PLC's adjusted to correct settings and Lamps replaced; All-Sat
09 - Working and Living Conditions › 092 - Working Conditions › Ropes and wires
Issued 10 July 2018 Resolved
Top rail course (wire rope) was found missing. Replace so that maximum height is at least 39.5" IAW 46 CFR 92.25-5.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 August 2018
Resolved 27 July 2018
Resolution: Bulwarks reinstalled after completing mission with SpaceX.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 10 July 2018 Resolved
Renew expired batteries for all ring buoy water lights prior to operating.
Action required: 17 - Rectify deficiencies prior to departure
Due 10 July 2018
Resolved 15 August 2018
Resolution: Batteries renewed. O-rings did not seal water light.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 10 July 2018 Resolved
Repair inoperable running lights port and starboard sides and anchor light prior to opreating.
Action required: 17 - Rectify deficiencies prior to departure
Due 10 July 2018
Resolved 15 August 2018
Resolution: Nav light panel did not have power when visited for def check.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 10 July 2018 Resolved
Renew inoperable and/or weak emgergency light batteries thru out the vessel prior to operating.
Action required: 17 - Rectify deficiencies prior to departure
Due 10 July 2018
Resolved 27 July 2018
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 10 July 2018 Resolved
Renew gasket to WTD at entry to bow thruster space.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 August 2018
Resolved 27 July 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 10 July 2018 Resolved
Prove proper operation of reverse power relay for SSDG#1.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 August 2018
Resolved 27 July 2018
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 July 2018 Resolved
Renew extinguished lamp on the generator switchboard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 August 2018
Resolved 27 July 2018
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 July 2018 Resolved
Secure receptacles above the port engine room escape and overhead outside the bow thruster space.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 August 2018
Resolved 27 July 2018
Construction/Loadline › Hull › Side Shell
Issued 2 May 2017 Resolved
Damage on STBD bow, aprox 8'X8'. Complete temp repar on stem crack, aprox 8"long by 1/16" prior to transiting to Conrad Shipyard in Morgan City, LA to conduct permanent repairs. Contact Morgan City CG Inspections Office to coordinate repair proposa. All repairs are to be completed to satisfaction of cognizant OCMI prior to vessel operations.
Action required: 705 - Other - as specified
Due 1 June 2017
Resolved 1 June 2017
Resolution: Rcvd repair proposal and maintained oversight in conjuctino with ABS for repairs. Repairs complete satisfactory.
Lifesaving › Inflatable Liferafts › Not on Board
Issued 24 March 2017 Resolved
Condition: Invalid
Action required: 705 - Other - as specified
Due 24 April 2017
Resolved 11 April 2017
Resolution: Liferafts installed to meet Subchapter I regulations
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 8 March 2017 Resolved
Condition: Invalid
Action required: 705 - Other - as specified
Due 24 April 2017
Resolved 11 April 2017
Resolution: Fire and Safety Plan updated to include liferafts and remove life floats
Lifesaving › Lifefloat › Serviceable
Issued 28 May 2014 Resolved
Lifefloat had cracked shell. Vsl limited to twenty (20) persons on board until lifefloat is replaced
Action required: 705 - Other - as specified
Resolved 29 May 2014
Resolution: New lifefloat on board
Lifesaving › Lifebuoys › Serviceable
Issued 5 October 2010 Resolved
Replace 2 damaged life rings on bridge.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 October 2010
Resolution: New life rings placed into service.
Electrical › Electric Generation Source (service) › Overcurrent Device
Issued 5 October 2010 Resolved
Reverse power relay did not function properly
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 October 2010
Resolution: proper operation of reverse power relay proven to inspector
Communications › Radio Communications › Emergency Source of Power
Issued 5 October 2010 Resolved
E-power needed for radios/PA and lighting
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 October 2010
Resolution: E-power/lighting proven thorughout vessel for inspector

Casualty record · 5

3 February 2009Routine · role: Involved in a Marine Casualty · activity 3411655
29 January 2011Routine · role: Involved in a Marine Casualty · activity 3937392
2 May 2017Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 6138042
9 December 2018Routine · role: Involved in a Marine Casualty · activity 6607010
7 May 2024Routine · role: Involved in a Marine Casualty · activity 7910074
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

ADRIATIC (2009–2011). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.