CCL 27 is a 2007 tank barge. The Coast Guard has recorded 24 inspections since 2007, most recently in January 2026, along with 6 deficiencies and 1 operational control.
Records from 2007 to 2026. Most recent: inspection, 28 January 2026.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Registered dimensions (L × B × D)200.0 ft × 35.0 ft × 12.5 ft
Registered tonnagegross 735 / net 735
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderC & C MARINE · BELLE CHASSE, LA, UNITED STATES · built 2007
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeBox
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 6 August 2025 · expires 30 September 2026
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it735 - Simplified, Gross Ton 735 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page
24 inspections, each with its date, unit and type; 6 deficiencies with the resolution recorded against each; 1 operational control with the dates imposed and removed; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
PlansSign in
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 25 February 2025Resolved
Each pressure-vacuum relief valve must be of a type approved for the pressure and vacuum relief setting desired. Repair or replace PV valve to meet pressure setting with CG approved plans. Currently vessel has 2.0 psi pressure setting and approved plans require 3.0 psi.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2025
Resolved 19 March 2025
Resolution: PV valve changed out. See deficiency docs.
Scantlings, material, and workmanship shall be at least equivalent to the requirements of ABS or other recognized classification society. Make permanent repair to damage IWO bow void hull plating and associated internal framing prior to loading cargo. Repairs are to be to the satisfaction of the attending USCG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 March 2021
Resolved 12 April 2021
Resolution: Repaired as original.
Construction/Loadline › Hull › Stiffener
Issued 16 January 2015Resolved
Prior to loading, make permanent repairs to the damaged side chord IWO #2P wing void.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 February 2015
Resolved 21 January 2015
During Periodic Inspection, found Cargo Pump Pressure Relief Valve set pressure at 188 PSI. Issued requirement to replace/reset for 125PSI.
Action required: 705 - Other - as specified
Due 3 December 2010
Resolved 3 December 2010
Resolution: Valve recalibrated for 125PSI.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 28 November 2007Resolved
Prior to conducting oil cargo operations, provide valid vessel response plan IAW 33 CFR 155.1030.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 June 2008
Documentation › Safety/Response Plans/Programs › General Arrangement Plans
Issued 28 November 2007Resolved
Provide approved Hazardous Area Plan.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 December 2007
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.