MAURY USCG vessel records Sign in
← All vessels

KLAZINA-C

KLAZINA-C is a 2007 freight ship. The Coast Guard has recorded 5 inspections since 2007, most recently in January 2010, along with 4 deficiencies.

Records from 2007 to 2010. Most recent: inspection, 24 January 2010.

Built
2007
Last inspected
24 January 2010
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9384186 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
894798
Flag
UNITED KINGDOM
—
Maury page id
psix-894798

Inspections, by type

Years with a record 4 calendar years (2007–2010)
The 5 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it2877 - Convention (Subpart B), Net Ton
7853 - Dead Weight, Ton
10953 - Displacement, Ton
5629 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 5

24 January 2010 ISPS II Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3668573
13 April 2009 Deficiency Check · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3451460
4 September 2008 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3317547
22 July 2008 Ballast Water Examination · Deficiency Check · NPV Safety Exam · ISPS II Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3263427
24 June 2007 MARPOL Annex V Examination · ISPS II Exam · MARPOL Annex I Examination · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2965797

Deficiency record · 4

Electrical › Electric Generation Source (service) › Generator
Issued 4 September 2008 Resolved
1499 - Propulsion & Aux. Machinery - Main source of electrical power shall consist of at least two generating sets. This ofc rcvd a class rpt stating that aux gen #2 is being taken offline until perm repairs can be done. Vessel still has auxiliary generator #1, EDG, and a power pack on deck. Class to attest to proper operation and set up of power pack. SOLAS 74 CONS ED 2004 II-1, 41.1
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 September 2008
Resolution: Class inspected cable runs and connections to #2 generator bus. Deck mounted power supply was run in parallel and in single up mode satisfactorily. Power pack is rated at 500 KW. Class confirmed until 02Oct08 Statutory matters without objections.
Electrical › Electric Generation Source (service) › Generator
Issued 4 September 2008 Resolved
This office received a class report from GL stating that #2 Generator has been taken offline until permanent repairs can be done. Condition of class states that licensed engineer must be in e/r at all times while u/w and a licensed engineer mans the EDG room while transiting tributaries. Class to attest to proper repair of #2 Aux generator. SOLAS 74 CONS ED 2004 II-1, 41.1
Action required: 705 - Other - as specified
Due 6 October 2008
Resolved 4 October 2008
Resolution: #2 Generator was repaired by Manufacturer approved technicians. Class attested to repair of #2 Generator. Class Report was received by Sector St Petersburg.
Electrical › Electric Generation Source (emergency) › Generator
Issued 10 July 2008 Resolved
EMERGENCY DIESEL GENERATOR CAN NOT CONTINUOUSLY OPERATE IN AUTOMATIC MODE.
Action required: 705 - Other - as specified
Resolved 18 July 2008
Resolution: EDG control unit repaired and tested satisfactory.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 10 July 2008 Resolved
GROUND FAULT FOUND ON 220 VOLT PANEL IN M/E CONTROL PANEL.
Action required: 705 - Other - as specified
Resolved 25 July 2008
Resolution: Ground fault identified and repaired.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.