← All vessels
NORMAN F MCCALL
NORMAN F MCCALL is a 2007 freight ship. The Coast Guard has recorded 20 inspections since 2008, most recently in May 2019, along with 32 deficiencies and 1 operational control.
Records from 2008 to 2019. Most recent: inspection, 21 May 2019.
- Built
- 2007
- Last inspected
- 21 May 2019
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 32 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
1201451
9407782 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDD8277
895226
Flag
UNITED STATES
366665000
Maury page id
psix-895226
Inspections, by type
The 20 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it2184 - Convention (Subpart B), Gross Ton
803 - Convention (Subpart B), Net Ton
2931 - Dead Weight, Net Ton
803 - Convention (Subpart B), Net Ton
2931 - Dead Weight, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
WDD8277MMSI 366665000 · active · compulsorily equipped · granted 17 May 2017, expires 19 June 2027
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 20
21 May 2019
ACP Annual Oversight · MTSA/ISPS Verification · Annual Inspection
Physical examination · Activities Europe · Activity 6689406
20 June 2018
ACP Drydock Oversight · Drydock Exam
Physical examination · Activities Europe · Activity 6450210
12 June 2018
Administrative Inspection
Administrative · Activities Europe · Activity 6446451
12 March 2018
COI Inspection · Annual Inspection · ACP COI Oversight · MTSA/ISPS Verification
Physical examination · Activities Europe · Activity 6370041
6 March 2018
Administrative Inspection
Administrative · Activities Europe · Activity 6366634
16 February 2017
ACP Periodic Oversight · MTSA/ISPS Verification · Annual Inspection · ACP Annual Oversight
Physical examination · Activities Europe · Activity 6089349
20 October 2016
Administrative Inspection
Administrative · Activities Europe · Activity 6029765
21 July 2016
MTSA/ISPS Verification · ACP Annual Oversight · Deficiency Check · Annual Inspection
Physical examination · Activities Europe · Activity 5947818
23 May 2016
Administrative Inspection
Administrative · Activities Europe · Activity 5883977
13 June 2014
ACP Annual Oversight · Annual Inspection
Physical examination · Activities Europe · Activity 4887621
5 March 2014
Administrative Inspection
Administrative · Activities Europe · Activity 4810176
19 June 2012
ACP Annual Oversight · MTSA/ISPS Verification · DAPI Audit · Annual Inspection
Physical examination · Activities Europe · Activity 4318601
9 February 2011
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3942062
11 May 2009
Annual Inspection · ACP Annual Oversight
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3474341
20 March 2009
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3437110
30 October 2008
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3354312
28 July 2008
Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3282363
25 March 2008
Initial Certification · ACP COI Oversight · Ballast Water Examination · MTSA/ISPS Verification
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3170983
13 February 2008
Plan Review (Other than "T") · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3147051
6 February 2008
Plan Review (Other than "T")
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3142822
Deficiency record · 32
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 20 October 2016
Resolved
starboard shaft fuse has blown fuse that made it inoperable.
Engineering › Generator (propulsion-electric) › Fuse (overload/over current protection)
Issued 20 October 2016
Resolved
Make repairs and attest to the proper operation of the starboard drive prior to conducting any operations.
Operations/Management › Casualty Reporting/Post-Casualty Actions › Notice of Marine Casualty
Issued 20 October 2016
Resolved
Make the proper notification in the form of a CG-2692 to the cognizant OCMI for the failure of the stbd drive motor that occurred on 11 Oct 2016.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 20 October 2016
Resolved
Replace all gaskets on watertight doors to include scuttles/hatches below the main deck with the correct material and adjust as needed.
Engineering › Electric Propulsion System › Breaker Circuitry
Issued 20 October 2016
Resolved
STBD Drive circuit breaker continues to open. Vessel must provide a class report attesting to the proper operation of the STBD drive prior to conducting operations.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 23 August 2016
Resolved
Adjust all quick acting watertight doors throughout the vessel.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 23 August 2016
Resolved
Replace gasket on the quick acting watertight door for the Engine Room escape.
Construction/Loadline › Markings › Load Line Mark
Issued 23 August 2016
Resolved
Paint the port and stbd Load Line Plimsol marks.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 23 August 2016
Resolved
Adjust fire doors in locations as discussed to close properly and latch.
Fire Fighting › Semiportable CO2 Fire Extinguishers › Discharge Hose
Issued 23 August 2016
Resolved
Replace CO2 hose on the O2 deck paint locker and spare portable CO2 extinguisher in the CO2 Room.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 23 August 2016
Resolved
Provide and install blank for the electrical panel opening for EP DC-3.
Documentation › Logs/Records › Operational Procedures for Engines or Equipment
Issued 23 August 2016
Resolved
Properly tag-out the Harbor engine supply and hot water heater in accordance with the ship's maintenance procedures.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 23 August 2016
Resolved
Provide and install cover on light in the Laundry Room.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 23 August 2016
Resolved
Provide guard for light in walk-in freezer.
Fire Fighting › Structural - A Class Divisions › Stairways
Issued 23 August 2016
Resolved
Restore fire-protective integrity of all cable penetrations in the main vertical stairwell.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Location
Issued 23 August 2016
Resolved
Provide portable fire extinguisher onboard the rescue boat.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 26 July 2016
Resolved
In accordance with the procedural amendments for offshore supply vessels enrolled in the ACP program message you have a 30 day extension beyond the 3 month window after the anniversary date and must complete an annual inspection by the specified date.
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 13 June 2014
Resolved
400 volt ROV electrical supply panel box is severely wasted and unsafe for use. Additionally, the grounding cable wasted and broken. replace or repair before use or at next dry-dock.
Fire Fighting › Fire Hydrants › Condition
Issued 13 June 2014
Resolved
Replace/repair DC rectifier for port monitor to allow proper remote operation.
Documentation › Markings/Placards › Warning Signs
Issued 13 June 2014
Resolved
Post CO2 warning placards near entryways of spaces that contain, are protected and adjacent to fixed CO2 firefighting equipment.
Lifesaving › Rescue Boat › Propulsion Starting System
Issued 13 June 2014
Resolved
Replace "Kill Switch"; missing.
Lifesaving › Rescue Boat › Construction
Issued 13 June 2014
Resolved
Provide CG approval certificate for the rescue boat to prove CG approval and type of boat (Rescue vs. Fast rescue).
Communications › Radio Communications › VHF Radiotelephone
Issued 13 June 2014
Resolved
Replace missing VHF radio in rescue boat.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 13 June 2014
Resolved
Hydro test all outdated MUD transfer hoses.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 13 June 2014
Resolved
Replace all worn/damaged fuel oil transfer hoses.
Communications › Alarms/Indicators › Fire Alarm
Issued 13 June 2014
Resolved
Ensure displayed name on bridge fire alarm panel matches location being protected.
Stability › Watertight Integrity › General
Issued 13 June 2014
Resolved
Ensure proper operation of water tight door indicating panel.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 26 May 2012
Resolved
COD 'managing owner' does not match COI 'owner' and CSR 'registered owner'. Submit for corrected COD.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 26 May 2012
Resolved
Paint side light shields flat black as opposed to gloss black as per NAVRULES, Annex 1, 84.09
Documentation › Logs/Records › Logbook (official)
Issued 26 May 2012
Resolved
Ensure all required entries are being made into Official Log Book. Generator and emergency power testing is not being logged currently. As per 46 CFR 131. Verify compliance at next attendance.
Construction/Loadline › Structures › Scuttle
Issued 26 May 2012
Resolved
Repair damaged door alarm switch at port side drive motor space.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 26 May 2012
Resolved
Post EAP hotline phone number in public spaces and prove documentation of crew training. 46 CFR 16.401.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.