MAURY USCG vessel records
← All vessels

DUMBLEDORE

DUMBLEDORE is a 2007 tank ship. The Coast Guard has recorded 16 inspections since 2016, most recently in December 2022, along with 3 deficiencies and 2 operational controls.

Records from 2016 to 2022. Most recent: inspection, 26 December 2022.

Built
2007
Last inspected
26 December 2022
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 26 December 2022
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2016–2022)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9325611
895293
Flag
PANAMA
Maury page id
psix-895293

Documentation record

Tonnage as PSIX records it31433 - Convention (Subpart B), Gross Ton
14001 - Convention (Subpart B), Net Ton
63755 - Displacement, Metric Ton
53815 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 16

26 December 2022 COC-CHEM & TVE Renew · PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7613010
24 December 2022 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7612712
31 January 2022 PSC B · COC-TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7387178
11 December 2021 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7366413
26 January 2021 COC-TVE Annual · Ballast Water Examination · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7128538
23 January 2021 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7129603
16 January 2020 COC-TVE Renew · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6889937
12 November 2019 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6854271
11 November 2019 Administrative Inspection
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6856345
5 February 2019 COE-Administrative
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6620247
11 January 2019 Ballast Water Examination · ISPS II Exam · COC-TVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6608963
29 April 2018 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6401734
21 November 2017 Ballast Water Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6308830
10 June 2017 COE-Administrative · COE-Offshore
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6168336
10 November 2016 Ballast Water Examination · COC-TVE Annual · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6033727
22 January 2016 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5802115

Deficiency record · 3

99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 December 2022 Resolved
99101-Suitable marked decontamination showers and eyewash shall be available on deck in convenient locations. The showers and eyewash shall be operable in all ambient conditions. PSCO observed the stbd side shower/eyewash not working and the port side was leaking at several conections on the piping. The crew was able to repair the leaks on the port side however, the stbd side was not able to be fixed during the exam. 74 SOLAS 20 VII/10.1
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 December 2022
Resolution: Received class report stating that the Starboard shower / eyewash piping connections gaskets and insulation have been renewed by the crew. Arrangement were tested and found sound and free of leaks.
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 31 January 2022 Resolved
Sludge oil tanks shall be provided and: shall have no discharge connections to the bilge system except as provided in regulation 12.3. PSCO observed valve (separate of shore connection piping) tieing discharge of bilge and sludge transfer pumps. MARPOL I/12.3
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 February 2022
Resolved 2 February 2022
Resolution: Reviewed and accepted Class NK report. Valves removed and flanges blanked with seals.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 31 January 2022 Resolved
The liferaft painter system shall provide a connection between the ship and the liferaft and shall be so arranged as to ensure that the liferaft when released and, in the case of an inflatable liferaft, inflated is not dragged under by the sinking ship. PSCO observed stbd liferaft painter improperly secured to hull. SOLAS III/34, LSA 4.1.6.1
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 31 January 2022
Resolution: PSCO observed painter arrangement reconfigured properly.

Ownership record