Records from 2007 to 2026. Most recent: inspection, 19 June 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 17
19 June 2026
Administrative Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8426951
19 May 2026
PSC B
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 8372595
15 October 2025
PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8251962
4 August 2025
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8202798
5 March 2025
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8088543
1 March 2025
PSC A
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8086472
5 May 2016
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5869316
23 February 2016
Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5820470
15 December 2015
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5781820
13 May 2014
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4856632
18 August 2011
Spot Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4119154
14 May 2009
Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3474321
3 April 2009
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3445622
15 May 2008
Random ISPS/MTSA/PSC
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3207183
29 November 2007
ISPS II Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3106509
21 June 2007
MARPOL Annex V Examination · PII Safety Exam · ISPS II Exam · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2968822
21 June 2007
Type not recorded
No type recorded · Maritime Safety & Security Team New York (91106) · Activity 2969275
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 19 May 2026
Resolved
The steering gear components and the rudder stock shall be of sound and reliable construction to the satisfaction of the Administration. During steering tests, PSCO observed both the #1 and #2 steering gear pumps leaking. 74SOLAS(04) II-I/29.2.1, Code 17ac Prior to Departure.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 May 2026
Resolved 19 May 2026
Resolution: Crew made repairs and ABS technician attended to verify. CG accepted verbal ABS report with written report to follow due to surveyor's schedule.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 19 May 2026
Resolved
In meeting the requirements, the company should ensure that: any non-conformity is reported, with its possible cause. Due to the nature of deficiency 01, require an Internal Safety Auditand corrective action within three months. 74SOLAS(20) IX/5 ISM Code 10.2.2, ac
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 May 2026
Resolved 3 July 2026
Resolution: Vessel submit Class (ABS) ISM Vessel Audit Report.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 May 2026
Resolved
Whenever there is a hazardous condition either onboard a vessel or caused by a vessel or its operation, the master must immediately notify the nearest Coast Guard. Vessel failed to report hazardous steering gear conditions prior to entry into Port of Dutch Harbor.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 19 May 2026
Resolved 19 May 2026
Resolution: Unit pursued NOV for deficiency
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 1 March 2025
Resolved
74 SOLAS (20) III/20.2
Before the ship leaves port and at all times... ready for immediate use. PSACO observed inoperable helm steering.
Action: 16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 March 2025
Resolved 4 March 2025
Resolution: The broken gear of the lifeboat steering helm was replaced by the crew. The repair was examined and operationally tested to the stisfaction of the surveyor.
09 - Working and Living Conditions › 091 - Living Conditions › Galley, handlingroom (maintenance)
Issued 1 March 2025
Resolved
74 SOLAS (14) II-2/13.1.3
Addtional aids for escape shall be provided as necessary... for emergency situations. PSCO observed inoperable meat locker escape door mechanism.
Code: 40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 4 March 2025
Resolution: The door latch was repaired by the crew. Latch operation and alarm were tested to the satisfaction of the surveyor.
Construction/Loadline › Markings › Load Line Mark
Issued 15 December 2015
Resolved
1299-The ring, lines, and letters shall be painted in white or yellow on a dark ground or in black on a light ground. Plimsol mark is rusted over and not painted in a contrasting color. ICLL(88)I/8.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 23 February 2016
Resolved 23 February 2016
Resolution: Load line painted in contrasting colors, per pictures provided by agent.
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 15 December 2015
Resolved
0750-Thermal insulation of boundaries shall have due regard to the fire risk of the space and adjacent spaces and the fire integrity of the divisions shall be maintained at openings and penetrations. Outer layer of fire proof boundary was removed around bulkhead penetration in the engine room. 74SOLAS(09)II-2/9.1
Action required: 705 - Other - as specified
Resolved 15 December 2015
Resolution: Corrected on site and inspected by PSC Team.
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 21 June 2007
Resolved
The vessel's chief engineer's national license issued by the People's Republic of China (cert # JKA211200335006) does not match the Flag State endorsement (endorsing a national license from United Kingdom of Great Britain, cert# CoC0021722). The Flag State must endorse the current certificate held by the c/e (People's Republic of China, cert# JKA211200335006) or provide proof of the valid UK cert
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 July 2007
Resolved 22 June 2007