MAURY USCG vessel records
← All vessels

CANDY COUNTER

CANDY COUNTER is a 2007 passenger vessel (inspected). The Coast Guard has recorded 15 inspections since 2016, most recently in March 2026, along with 12 deficiencies and 1 casualty investigation in 2023.

Records from 2016 to 2026. Most recent: inspection, 6 March 2026.

Built
2007
Last inspected
6 March 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 6 March 2026
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9550943
WDD8297
896377
Flag
UNITED STATES
Maury page id
psix-896377

Documentation record

Registered dimensions (L × B × D)157.2 ft × 30.0 ft × 13.1 ft
Registered tonnagegross 97 / net 66
ITC dimensions (L × B × D)157.2 ft × 30.0 ft × 13.1 ft
ITC tonnagegross 359 / net 107
BuilderSWIFTSHIPS SHIPBUILDERS LLC · MORGAN CITY, LA, UNITED STATES · built 2007
Hull materialAluminum
PropulsionJet Drive
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portMORGAN CITY, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 2 May 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it97 - Regulatory (Subpart C or D), Gross Ton
359 - Convention (Subpart B), Gross Ton
66 - Regulatory (Subpart C or D), Net Ton
107 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 15

6 March 2026 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8320882
3 April 2025 Drydock Exam · COI Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8104371
30 October 2024 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8027535
21 August 2023 Internal Structural Exam · Deficiency Check · Annual Inspection · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7773377
22 June 2023 Damage Survey
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7721036
22 June 2023 Examination of Repairs · Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7721765
22 June 2023 Type not recorded
No type recorded · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7757046
5 October 2022 Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7572208
28 July 2021 Drydock Exam · Examination of Repairs · Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7270353
5 November 2020 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7090366
26 August 2019 Drydock Exam · Examination of Repairs · Internal Structural Exam · Administrative Inspection · Hull Examination · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6803074
7 August 2018 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6503729
4 May 2018 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6405565
2 August 2017 Administrative Inspection · Internal Structural Exam · Drydock Exam · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6229830
3 August 2016 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5961266

Deficiency record · 12

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 April 2026 Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Battery Charger in vicinity of port inboard Main Diesel Engine was missing a cover protecting the exposed terminals.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2026
Resolved 13 April 2026
Resolution: Received satisfactory photos of repair.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 10 April 2026 Resolved
Each disposable hydrostatic release unit must be marked with an expiration date of two years after the date on which the unit is installed. EPIRB hydrostatic release was expired as of October 2025. Replaced during inspection.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 10 April 2026
Resolution: Release was replaced on site.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 10 April 2026 Resolved
The OCMI may require an inspection and testing whenever a repair or alteration is undertaken. A cracked weld was found on the PORT generator exhaust piping.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2026
Resolved 13 April 2026
Resolution: Received satisfactory photo of repair.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 October 2024 Resolved
Piping used in a vital system must: be composed of ferrous materials except when nonferrous metallic piping materials are permitted by 182.730. The following def's were noted. Replace Port MDE raw water pipe due to numerous leaks Replace raw water pipe leading to the port main exhaust.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 13 November 2024
Resolved 1 November 2024
Resolution: PORT MDE raw water inlet piping leak. Approximately 8" section cropped and renewed, SAT. Port exhaust cooling water piping leak. Approximately 7' section cropped and renewed, SAT
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 October 2024 Resolved
For the purpose of flexibility only, flexible hose installed in lengths of not more than 30 inches and subject to pressures of not more than 5 psig, may meet the following requirements: USCG type A1, A2, B1, or B2 flexible hoses may be accepted. The port fuel return line is not serviceable. Replace with J-1942 hose of any length or USCG type A1 hose of not greater than 30" if the system does not exceed 5 psig.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 November 2024
Resolved 1 November 2024
Resolution: Replaced with 27" length of USCG type A-1 fuel hose, SAT
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 October 2024 Resolved
A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. The saltwater cooling pipe for the starboard jets passes through the aft engine room watertight bulkhead and is leaking at the bulkhead.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 November 2024
Resolved 1 November 2024
Resolution: Cracked collar repaired, SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 October 2024 Resolved
Piping, including valves, pipe fittings, and flanges, conveying vapor, gas, or liquid, the temperature of which exceeds 150 F, must be suitably insulated where necessary to prevent injuries. The starboard generator jacket water piping leading to the expansion tank was not covered to prevent injury.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 November 2024
Resolved 1 November 2024
Resolution: Piping wrapped with fiberglass insulating fabric from engine outlet to expansion tank, SAT
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 28 August 2023 Resolved
Each vessel that operates on high seas must have EPIRB installed to automatically float free and activate. Vessel must register new EPIRB and proper installation w/ hydrostatic release.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 28 August 2023
Resolution: Verified new installation and registration of EPIRB.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 August 2023 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers and crew from electrical hazards including fire or shock. Vessel must secure wires on battery charger. Vessel must clean both generator with oil buildup.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 September 2023
Resolved 28 August 2023
Resolution: Verified wires secured and generators cleaned.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 August 2023 Resolved
Exhaust systems must ensure minimum risk of injury to personnel. Protection must be provided. Ensure protection on #1 and #3 MDE exhausts. Re secure bracket on #3 MDE exhaust.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 September 2023
Resolved 28 August 2023
Resolution: Verified proper lagging installation.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 21 August 2023 Resolved
Each ring buoy must be marked with capital letters. Re stencil life buoy lettering for vessel name and hailing port.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 September 2023
Resolved 28 August 2023
Resolution: Verified proper stenciling of ring buoys.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 22 June 2023 Resolved
Whenever damage or deterioration to hull plating or structural members that may affect the seaworthiness of a vessel is discovered or suspected, the cognizant OCMI may conduct an internal structural examination in any affected space...and may require the vessel to be drydocked or taken out of service to assess the extent of the damage, and to effect permanent repairs. Vessel crew discovered a 1" x 1" puncture in the starboard side shell below the waterline in way of the generator room. Vessel is to transit directly to Diamond Services Shipyard in Amelia, LA to effect permanent repairs. Upon arrival, vessel is to contact MSU Morgan City Command Duty Officer at [phone withheld] and shall coordinate oversight of repairs prior to commencing any repair work.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 June 2023
Resolution: The hole was repaired to the satisfaction of the CG.

Casualty record · 1

22 June 2023Routine · role: Involved in a Marine Casualty · activity 7757046
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.