Records from 2007 to 2025. Most recent: inspection, 29 August 2025.
Documentation record
Registered dimensions (L × B × D)48.0 ft × 14.0 ft × 3.8 ft
Registered tonnagegross 10 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSUSQUEHANNA SANTEE BTWKS INC · WILLOW STREET, PA, UNITED STATES · built 2007
Hull materialAluminum
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationTwin Hull
Hailing portNORTH EAST, MD
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 19 February 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it10 - Simplified, Gross Ton
10 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 20
29 August 2025
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8225216
7 August 2025
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8204478
1 April 2022
Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7423994
20 September 2021
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7316112
17 September 2020
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7067733
9 September 2019
DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6805337
10 September 2018
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6542154
2 October 2017
DAPI Audit · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6237340
4 May 2017
Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6143695
5 December 2016
Annual Inspection · Deficiency Check · DAPI Audit · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6053319
4 December 2015
DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5778909
9 May 2012
Hull Examination · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4308195
13 December 2011
DAPI Audit · Annual Inspection · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4207264
13 December 2010
Annual Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3910560
9 December 2009
Annual Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3647511
4 March 2009
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3429632
5 December 2008
DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3380869
26 November 2007
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3104333
2 November 2007
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3091980
28 June 2007
Construction Oversight · COI Inspection · Simplified Stability Test · Hull Examination · Inclining Experiment
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2976237
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 5 December 2016
Resolved
Flexible fuel lines are experiencing UV damage. Repair/replace damaged flexible fuel lines.
46 CFR 182.720
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 December 2016
Resolved 16 December 2016
Resolution: Master installed new flexible fuel lines.
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 5 December 2016
Resolved
Flexible fuel line connection for main outboard engines were not double clamped. 46 CFR 182.720
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 December 2016
Resolved 16 December 2016
Resolution: All flexible fuel hose connections were double clamped.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 5 December 2016
Resolved
Portable fire extinguishers were missing service tags. Provide documentation that port. extinguishers were serviced. 46 CFR 176.810
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 December 2016
Resolved 16 December 2016
Resolution: All portable fire extinguishers were properly serviced.
Communications › Audible Communications › Horn/Whistle
Issued 5 December 2016
Resolved
Ships whistle inoperabel/barely audible. Ensure ships horn is fully audible. 33 CFR 86
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 December 2016
Resolved 16 December 2016
Resolution: Vessel provided adequate sound producing device.
Fire Fighting › Fire Bucket › Availability
Issued 5 December 2016
Resolved
Vessel does not have 3 labled fire buckets. Provide 2 additional fire buckets and ensure all fire buckets are properly marked. 46 CFR 181.610
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 December 2016
Resolved 7 December 2016
Resolution: Owner/operator has 03 properly marked fire buckets onboard.
Lifesaving › Lifebuoys › Serviceable
Issued 5 December 2016
Resolved
Vessel's lifering was worn and not servicable. Repair/replace lifering as needed
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 December 2016
Resolved 16 December 2016
Resolution: Vessel provided new adequate life ring.
Lifesaving › Hand Flares › Expired
Issued 14 December 2010
Resolved
All six (6) flares expired, replace as new.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 December 2010
Resolution: Six new flares were purchased and maintained o/b the vessel.
Lifesaving › Lifefloat › Float-free Link
Issued 14 December 2010
Resolved
Weak link for life floats too small. Replace with a wink link thats rated for 15 passengers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 January 2011
Resolved 17 December 2010
Resolution: Approipriate sized weak link purchased and installed on the life float.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 13 December 2010
Resolved
Drug consortium enrollment for Captain & crew missing, provide as required.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 January 2011
Resolved 17 December 2010
Resolution: Copy of drug enrollment certificate provided.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 13 December 2010
Resolved
Alcohol test kits expired, replace as new.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 January 2011
Resolved 17 December 2010
Resolution: Alcohol test kits purchased & maintained o/b the vessel.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 13 December 2010
Resolved
Eyewash missing, replace as new.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 January 2011
Resolved 17 December 2010
Resolution: Eyewash purchased & maintained o/b the vessel.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 9 December 2009
Resolved
Eye wash and asprin expired, replace as new.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 January 2010
Resolved 12 January 2010
Resolution: Renewed eye wash and asprin.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 9 December 2009
Resolved
Alcohol test kits expired, replace as new.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 January 2010
Resolved 12 January 2010
Resolution: Operator replaced alcohol test kits.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 28 June 2007
Resolved
Provide Certificate of Documentation.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 June 2007
Resolved 2 November 2007
Resolution: Attended vessel for NTZ inspection and cleared above deficiency.
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 28 June 2007
Resolved
Provide Radio Safety Certificate.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 November 2007
Resolution: Attended vessel for NTZ inspection and cleared above deficiency.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 28 June 2007
Resolved
Provide Tidal Current Tables.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 November 2007
Resolution: Attended vessel for NTZ inspection and cleared above deficiency.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 28 June 2007
Resolved
Apply hull markings to indicate baseline draft.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 November 2007
Resolution: Attended vessel for NTZ inspection and cleared above deficiency.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 28 June 2007
Resolved
Prove proper stowage of lifefloats and waterlights.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 November 2007
Resolution: Attended vessel for NTZ inspection and cleared above deficiency.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 28 June 2007
Resolved
Properly mount machinery space fire extinguisher.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 November 2007
Resolution: Attended vessel for NTZ inspection and cleared above deficiency.
Operations/Management › Drills/Instruction › Not Conducted
Issued 28 June 2007
Resolved
Conduct new to zone inspection to include machinery op test, drills & issuance of SPV decal.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 November 2007
Resolution: Attended vessel for NTZ inspection and cleared above deficiency.