MAURY USCG vessel records
← All vessels

MISS NANCY

MISS NANCY is a 2007 passenger vessel (inspected). The Coast Guard has recorded 10 inspections since 2016, most recently in August 2025, along with 6 deficiencies.

Records from 2016 to 2025. Most recent: inspection, 29 August 2025.

Built
2007
Last inspected
29 August 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 29 August 2025
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDD 7872
899302
Flag
UNITED STATES
Maury page id
psix-899302

Documentation record

Registered dimensions (L × B × D)48.0 ft × 14.0 ft × 3.8 ft
Registered tonnagegross 10 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSUSQUEHANNA SANTEE BTWKS INC · WILLOW STREET, PA, UNITED STATES · built 2007
Hull materialAluminum
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationTwin Hull
Hailing portNORTH EAST, MD
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 19 February 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it10 - Simplified, Gross Ton
10 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 10

29 August 2025 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8225216
7 August 2025 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8204478
1 April 2022 Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7423994
20 September 2021 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7316112
17 September 2020 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7067733
9 September 2019 DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6805337
10 September 2018 Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6542154
2 October 2017 DAPI Audit · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6237340
4 May 2017 Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6143695
5 December 2016 Annual Inspection · Deficiency Check · DAPI Audit · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6053319

Deficiency record · 6

Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 5 December 2016 Resolved
Flexible fuel lines are experiencing UV damage. Repair/replace damaged flexible fuel lines. 46 CFR 182.720
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 December 2016
Resolved 16 December 2016
Resolution: Master installed new flexible fuel lines.
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 5 December 2016 Resolved
Flexible fuel line connection for main outboard engines were not double clamped. 46 CFR 182.720
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 December 2016
Resolved 16 December 2016
Resolution: All flexible fuel hose connections were double clamped.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 5 December 2016 Resolved
Portable fire extinguishers were missing service tags. Provide documentation that port. extinguishers were serviced. 46 CFR 176.810
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 December 2016
Resolved 16 December 2016
Resolution: All portable fire extinguishers were properly serviced.
Communications › Audible Communications › Horn/Whistle
Issued 5 December 2016 Resolved
Ships whistle inoperabel/barely audible. Ensure ships horn is fully audible. 33 CFR 86
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 December 2016
Resolved 16 December 2016
Resolution: Vessel provided adequate sound producing device.
Fire Fighting › Fire Bucket › Availability
Issued 5 December 2016 Resolved
Vessel does not have 3 labled fire buckets. Provide 2 additional fire buckets and ensure all fire buckets are properly marked. 46 CFR 181.610
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 December 2016
Resolved 7 December 2016
Resolution: Owner/operator has 03 properly marked fire buckets onboard.
Lifesaving › Lifebuoys › Serviceable
Issued 5 December 2016 Resolved
Vessel's lifering was worn and not servicable. Repair/replace lifering as needed
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 December 2016
Resolved 16 December 2016
Resolution: Vessel provided new adequate life ring.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.