← All vessels
MOZART
Freight Ship · General Dry Cargo Ship class · Built 2000s · USCG East District (CGD-E) · Other hulls named MOZART
MOZART is a 2007 freight ship. The Coast Guard has recorded 20 inspections since 2007, most recently in August 2019, along with 10 deficiencies and 4 operational controls.
Records from 2007 to 2019. Most recent: inspection, 8 August 2019.
- Built
- 2007
- Last inspected
- 8 August 2019
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 10 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9337274 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
A8MA9
900832
Flag
LIBERIA
—
Maury page id
psix-900832
Inspections, by type
…with no type recorded6
Years with a record
11 calendar years (2007–2019)
The 20 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it28616 - Convention (Subpart B), Gross Ton
14769 - Convention (Subpart B), Net Ton
39338 - Dead Weight, Ton
51309 - Displacement, Ton
14769 - Convention (Subpart B), Net Ton
39338 - Dead Weight, Ton
51309 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 20
8 August 2019
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6776823
10 May 2019
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6680975
7 May 2019
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6678628
6 March 2019
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6637044
3 February 2018
Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6348936
30 December 2017
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6328574
5 December 2016
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6052640
21 April 2016
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5859565
9 November 2015
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5759914
20 October 2014
ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5008361
28 February 2012
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4250770
28 February 2012
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4253025
24 February 2012
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4250781
7 September 2010
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3843837
14 July 2009
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3533666
9 July 2009
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3529757
2 July 2008
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3254604
7 July 2007
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2986634
7 July 2007
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2986671
3 July 2007
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2982138
Deficiency record · 10
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 March 2019
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. The shaft seal and the shaft bearing were found to be leaking oil. 17AC
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 6 March 2019
Resolved
Where "A" class divisions are penetrated, such penetrations shall be tested in accordance with the fire test procedures code, cable runs and penetrations behind ECR in transformer space were found to be un-insulated. 17AC
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 6 March 2019
Resolved
General arrangements plans shall be permanently exhibited for the guidance of the ship's officers, showing clearly for each deck the control stations, the various fire sections enclosed by "A" class divisions. "A-60" fire door between engine room & gym missing from fire control plan. 17AC
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 6 March 2019
Resolved
The construction of doors and door frames in "A" class divisions, with the means of securing them when closed, shall provide resistance to fire as well as to the passage of smoke and flame equivalent to that of the bulkhead in which the doors are situated. "A-60" doors connecting steering gear room and changing room to the engine room failed to self-close securely, allowing for the potential for passage of smoke and flame. The door to steering gear room is worn, no longer providing fire boundary. 17AC
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 6 March 2019
Resolved
After any survey of the ship under regulations 7, 8, 9 or 10 has been completed, no change shall be made to the structural arrangement, machinery, equipment, and other items covered by the survey without sanction of the administration. The storage locker on A deck was converted to an electrical workshop without being accounted for on the general arrangements and fire control plan. 17AC
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 6 March 2019
Resolved
The machinery...shall be of a design and construction adequate for the service for which they are intended. The diesel return line on the port side engine room 2nd deck is leaking at valve, pooled oil on deck beneath valve. 40AC
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Insulation wetted through (oil)
Issued 6 March 2019
Resolved
The machinery...shall be so installed and protected as to reduce to a minimum any dangers to persons on board, due regard being paid to moving parts, hot surfaces. Lagging is visibly worn and exposes steam lines. 40AC
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 6 March 2019
Resolved
The fire resistance of doors shall be equivalent to that of the division in which they are fitted, this being determined in accordance with the fire test procedures code. The door to the pipe duct on A deck is on the fire control plan as an "A" class self-closing door but the door is not marked as an "A-0" door nor does it close via the self-closing device. 40AC
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 6 March 2019
Resolved
The steering gear compartment shall include handrails and gratings or other non-slip surfaces to ensure suitable working conditions. The grating for the emergency steering solenoids is cracked at the weld, no longer providing suitable working conditions. 40AC
Navigation › Voyage Data Recorder › Voyage Data Recorder (VDR)
Issued 30 December 2017
Resolved
1599: To assist in casualy investigations, ships, when engaged on international voyages, subject to provisions of reg. 1.4, shall be fitted with a voyage data recorder. Vessels VDR recieved a hard drive failure alarm @0600 30 DEC inbound Savannah river. SOLAS 74a (09 cons) V/20.1 50 a,c
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.