ASIA CEMENT NO. 6

ASIA CEMENT NO. 6 is a 1995 freight ship. The Coast Guard has recorded 21 inspections since 2016, most recently in December 2025, along with 9 deficiencies and 2 operational controls.

Records from 2016 to 2025. Most recent: inspection, 12 December 2025.

Built
1995
Last inspected
12 December 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 12 December 2025
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9112832
900966
Flag
TAIWAN
Maury page id
psix-900966

Documentation record

Tonnage as PSIX records it7614 - Convention (Subpart B), Gross Ton
3005 - Convention (Subpart B), Net Ton
7614 - Simplified, Gross Ton
3005 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 21

12 December 2025 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8282411
8 December 2025 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8278846
3 September 2025 Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 8226614
9 August 2025 PSC B · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 8202482
20 January 2025 PSC B
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8063183
12 August 2024 VRP Review
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7980038
6 May 2024 PSC B
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7905783
25 September 2023 PSC B
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7794228
3 June 2022 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7467167
6 June 2021 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7217550
21 September 2020 PSC B
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7059622
25 January 2020 Deficiency Check · PSC B
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6895890
20 October 2019 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6837020
14 February 2019 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6622859
12 February 2019 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6624177
30 May 2018 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6428652
22 February 2018 Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6428646
6 December 2017 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6314483
4 May 2017 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6136021
19 October 2016 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6021479
5 April 2016 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5844152

Deficiency record · 9

14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 10 August 2025 Resolved
Oil filtering equipment referred in paragraph 1 of this regulation shall be of a design approved by the Admin and shall be such as will ensure that any oily mixture discharged into the sea after passing through the system has an oil content not exceeding 15 ppm. PSCO discovered oil on the valve stem for valve 27V which is identified on bilge system drawing M35-227. Valve 27V is the last valve in the OWS overboard piping before the skin valve. The crew removed additional piping on the discharge side of valve 27V and oil was observed in that piping as well and on the inboard side of the skin valve, valve 15V. No sheen or emulsification was observed in the navigable waterway on the water side of the skin valve. Valve 27V was disassembled by the crew and found corroded on the valve seat. Oil, in the return line to the Bilge Tank, seeps through valve 27V when closed and allows for free communication of oil into the piping that is discharged to sea. MARPOL 73/78 (2022 ed) Annex I, Reg. 14.6
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 September 2025
Resolved 4 September 2025
Resolution: Valve 27V and downstream piping were renewed. OWS 15 ppm alarm and shutdown functions were found in order by operational test. Downstream piping of valve 27V was dismantled after OWS operational test and found in order.
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 10 August 2025 Resolved
Oil filtering equipment referred in paragraph 1 of this regulation shall be of a design approved by the Admin and shall be such as will ensure that any oily mixture discharged into the sea after passing through the system has an oil content not exceeding 15 ppm. PSCO expanded the MARPOL exam and requested the crew to operate the OWS. The crew members were unable to operate the OWS due to an inoperable bilge separator suction pump dedicated for the OWS. PSCO was unable to determine if the OWS and OCM were functioning properly. MARPOL 73/78 (2022 ed) Annex I, Reg. 14.6
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 September 2025
Resolved 4 September 2025
Resolution: The inoperable bilge pump was dismantled and the cylinder liner and piston were renewed. OWS and OCM were found functioning properly by operational test
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 August 2025 Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to moving parts, hot surfaces and other hazards. PSCO observed the ballast pump leaking in the engine room. The salt water inlet piping bolted coupling is leaking from the bottom bolt at a rate of 1 gallon per hour. The ballast pump is leaking underneath from a reservoir gasket at a rate of 1/2 gallon per hour. SOLAS 74 (2004 cons) Ch. II-1 Reg 26.1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 September 2025
Resolved 4 September 2025
Resolution: The leaked ballast pump (Fire, Bilge & Ballast Pump) was dismantled and the mechanical seal, cover and bottom gasket, and damaged bolts were renewed and found in order by operational test.
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 9 August 2025 Resolved
Every candidate for certification as OICEW in a manned engine-room or as DDE in a PUMS on a seagoing ship powered by main propulsion machinery of 750KW propulsion power or more shall be required to demonstrate ability to undertake, at the operational level, the tasks, duties and responsibilities listed in column 1 of table A-III/1. The level of knowledge of the material listed in column 2 of table A-III/1 shall be sufficient for engineer officers to carry out their watch keeping duties. PSCO expanded the MARPOL exam and discovered that only one of the engineering officers on board (4th engineer) is familiar with the operation of the oily water separator (OWS). Engineering officers in charge of a watch shall be familiar with OWS requirements and operation as per column 2 of table A-III/1 in STCW. STWC 78 (2011 ed) Ch. III Section A-III/1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 September 2025
Resolved 4 September 2025
Resolution: The Chief Engineer conducted enhanced training for all watching engineers on OWS operation and MARPOL Annex I requirements, including startup, operation, 15 ppm monitoring, and automatic shutdown function. The training content, assessment results, an
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 20 October 2019 Resolved
Function of the fixed fire detection and fire alarm systems shall be periodically tested. Crew did not have the proper testing equipment for heat detectors. - SOLAS74(81)Chapter II-2/Reg 7.3.2
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 25 January 2020
Resolved 25 January 2020
Resolution: See attached Class survey and additional documentation. Also verified onboard during inspection.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 20 October 2019 Resolved
Self closing doors throughout the vessel did not have self closing operation. Doors must be capable of closing and not include hold back hooks. - SOLAS74(81)Chapter II-2/Reg 47.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 25 January 2020
Resolved 25 January 2020
Resolution: See attached Class survey and additional documentation. Also verified onboard during inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 20 October 2019 Resolved
Immersion suits shall be donned within two minutes, to include life jackets. Crew received further training to don suits. Vessel did not have appropriate sizes for the crew. Required purchase of new suits. SOLAS74(97)Chapter III/Reg 33 LSA CHII 2.3
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 25 January 2020
Resolved 25 January 2020
Resolution: See attached Class survey and additional documentation. Also verified onboard during inspection.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 14 February 2019 Resolved
The macinery shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to moving parts. In cement machinery room PSCO observed four blower electrical motors with the belt guards removed, exposing the rotating belts. Vessel's crew securely reinstalled guards on all four electical motors. 74SOLAS(97Cons) II-I/Reg26.1 10c
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 14 February 2019
Resolution: Vessel's crew securely reinstalled guards on all four electical motors.
Navigation › Voyage Data Recorder › Voyage Data Recorder (VDR)
Issued 6 December 2017 Resolved
Cargo ships of at least 3000GT but less than 20,000GT constructed before 1 JULY 2002, shall be fitted with a VDR which may be an S-VDR. PSCO observed alarm on VDR panel requiring crew to manually enter ship's heading into VDR. 74SOLAS(14) V/20.2.2
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 22 February 2018
Resolution: Received email correspondence from Class society attesting to rectification.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.