MAURY USCG vessel records
← All vessels

MAERSK OHIO

Built
2006
Last inspected
23 June 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 23 June 2026
…with no type recorded18
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9298698
903593
Flag
UNITED STATES
Maury page id
psix-903593

Documentation record

Registered dimensions (L × B × D)912.5 ft × 105.8 ft × 61.4 ft
Registered tonnagegross 50,686 / net 29,491
ITC dimensions (L × B × D)912.5 ft × 105.8 ft × 61.4 ft
ITC tonnagegross 50,686 / net 29,491
BuilderHYUNDAI HEAVY INDS CO LTD · KOREA, REPUBLIC OF · built 2006
Hull materialSteel
PropulsionDiesel Direct
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNORFOLK, VA
Endorsements, as the file codes themreg
DocumentationValid · issued 9 August 2025 · expires 30 September 2026
Service, as the file records itFreight Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it50686 - Convention (Subpart B), Gross Ton
29491 - Convention (Subpart B), Net Ton
61454 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 71 inspections, each with its date, unit and type; 17 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 2 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

LUCKY D Towing Vessel · MISLE 106371 · 29 August 2019 · activity 6809285VIRGINIA EXPRESS Freight Barge · MISLE 1543265 · 29 August 2019 · activity 6809285

Inspection history · 71

23 June 2026 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 8410939
14 June 2026 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 8404014
12 March 2026 Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 8325397
5 February 2026 MTSA/ISPS Verification · Administrative Inspection · MSP Select COI Oversight
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8306450
6 November 2025 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8265012
1 August 2025 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 8200457
20 May 2025 Annual Inspection · MSP Annual Oversight · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8139798
27 March 2025 Deficiency Check · Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8100976
21 March 2025 Deficiency Check
Physical examination · Activities Europe · Activity 8097550
4 March 2025 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 8088007
27 August 2024 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7995627
22 July 2024 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7964619
25 June 2024 Administrative Inspection
Administrative · Activities Europe · Activity 7942887
18 May 2024 Type not recorded
No type recorded · Activities Europe · Activity 7915392
25 April 2024 Annual Inspection · Administrative Inspection · MSP Annual Oversight
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7901510
13 October 2023 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7811833
22 June 2023 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7721230
16 June 2023 Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7716627
8 May 2023 Administrative Inspection · Annual Inspection · MSP Annual Oversight · MTSA/ISPS Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7683936
23 January 2023 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7626384
12 December 2022 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7607699
3 October 2022 Administrative Inspection
Administrative · Activities Europe · Activity 7570267
17 September 2022 Deficiency Check · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7561952
25 April 2022 Administrative Inspection · MSP Annual Oversight · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7437775
24 March 2022 MTSA Verification
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7417708
23 March 2022 Special
Type not classified · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7417801
23 March 2022 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7420523
20 March 2022 Type not recorded
No type recorded · Station Galveston · USCG Heartland District (CGD-H) · Activity 7415067
24 February 2022 Type not recorded
No type recorded · Activities Europe · Activity 7402906
4 December 2021 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7548269
28 November 2021 Administrative Inspection
Administrative · Activities Europe · Activity 7358011
29 July 2021 Administrative Inspection
Administrative · Activities Europe · Activity 7278774
29 April 2021 MSP COI Oversight · MTSA/ISPS Verification
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7178813
19 February 2021 Administrative Inspection
Administrative · Activities Europe · Activity 7142761
1 February 2021 Administrative Inspection
Administrative · Activities Europe · Activity 7134125
21 August 2020 Deficiency Check · Administrative Inspection
Physical examination · Activities Europe · Activity 7039755
19 August 2020 Type not recorded
No type recorded · Activities Europe · Activity 7042138
8 July 2020 Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7001381
23 April 2020 Security Plan Amendment Review - VSP · MSP Annual Oversight · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6943046
29 August 2019 Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6798670
29 August 2019 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6809285
21 June 2019 In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6723610
16 June 2019 Administrative Inspection · Damage Survey
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6715278
4 May 2019 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6726647
25 March 2019 MSP Periodic Oversight · Annual Inspection · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6648713
25 December 2018 Administrative Inspection
Administrative · Activities Europe · Activity 6602673
27 November 2018 Type not recorded
No type recorded · Activities Europe · Activity 6603420
5 October 2018 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6557774
1 October 2018 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6552791
14 September 2018 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6540541
13 August 2018 Administrative Inspection
Administrative · Activities Europe · Activity 6510178
5 July 2018 Administrative Inspection
Administrative · Activities Europe · Activity 6469081
5 July 2018 Type not recorded
No type recorded · Activities Europe · Activity 6476436
9 April 2018 Annual Inspection · Ballast Water Examination · Administrative Inspection · MTSA/ISPS Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6387698
24 March 2018 Administrative Inspection
Administrative · Activities Europe · Activity 6377741
13 June 2017 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6174318
12 June 2017 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6173754
13 May 2017 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6145279
5 April 2017 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6118413
22 March 2017 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6109755
9 March 2017 In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6101689
27 February 2017 Annual Inspection · MTSA/ISPS Verification
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6095789
5 January 2017 Administrative Inspection
Administrative · Activities Europe · Activity 6066248
4 January 2017 Type not recorded
No type recorded · Activities Europe · Activity 6066161
4 August 2016 Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5962172
16 June 2016 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5910598
24 March 2016 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5840764
8 March 2016 Administrative Inspection
Administrative · Activities Europe · Activity 5828940
3 February 2016 COI Inspection · DAPI Audit · MTSA/ISPS Verification
Physical examination · Activities Europe · Activity 5808598
3 January 2016 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5789992
1 January 2016 Damage Survey
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5801009

Deficiency record · 17

07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 May 2023 Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. Excessive water leakage from hypermist manifold gauge connection. 74 SOLAS (20) II-2/14.2.1.2
Action required: 15 - Rectify deficiencies by next port
Resolved 15 May 2023
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 8 May 2023 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Vessel’s rescue boat breaker box underneath the console was semi-open with an electrical conductor coming out from one side of its seam rather than from a gland. Current condition allows for water intrusion and chafing of the conductor. 74 SOLAS (20) III/20.2
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 15 May 2023
01 - Certificates & Documentation › 011 - Ships Certificates › Minimum Safe Manning Document
Issued 3 October 2022 Resolved
Sailing short 1 x 3rd mate
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2022
Resolved 14 October 2022
Resolution: Vessel is at full manning as of 14 October.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 23 March 2022 Resolved
Vessel reported a intermittent electrical fault of the #2 steering system. Provide casual factors leading to the failure and corrective actions taken prior to departure from next destination. 46CFR58.25-5(b)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 April 2022
Resolution: Lloyd's attended vessel on 24MAR22 to verify repairs were satisfactory. All sat.
08 - Alarms › N/A - No Subsystem › Boiler alarm
Issued 29 April 2021 Resolved
Each oil fired boiler intednded to operate without supervision shall have a safety which gives an alarm incase of flame failure. Boiler (aux) didn't alarm for a flame failure.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2021
Resolved 4 May 2021
Resolution: Accepted by class 2113315
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 April 2021 Resolved
After any survey of the ship under regulations 7, 8, 9 or 10 has been completed, no change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey without the sanction of the Administration. Engine room water fountain not permantely wired for use.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2021
Resolved 4 May 2021
Resolution: Accepted by class 2113315
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 29 April 2021 Resolved
Ship shall be designed, constructed and maintained in compliance with structural mechanical and electrical requiremjents of class. F deck starborad side ladder step is wasted; starboard life boat embarkation side hand rail has wastage; Bay 58 fowd starboard rail has wastage. Repair to satisfaction of class.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2021
Resolved 4 May 2021
Resolution: Accepted by class 2113315
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 8 July 2020 Resolved
Vessel shall have a 9 GHz radar and second radar of 3 GHz or 9 GHz. Vessel arrived at Sector Virginia with both radars inoperable. Repair to the satisfaction of the attending Classification Society prior to departure from port. SOLAS74 2004 V/20.2.7
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 July 2020
Resolution: Rectified deficiency to the satisfaction of the Classification Society.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 23 April 2020 Resolved
Vessel did not have on board 2 fire suits that were rated for fire entery.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 25 April 2020
Resolved 25 April 2020
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 29 August 2019 Resolved
The condition of the ship shall be maintained to conform with the provisions of the present regulations to ensure the ship in all respects will remain fit to proceed to sea without danger to the ship or persons aboard. The ship was struck by a container barge whose lines had parted following an engine casualty aboard its towing vessel. Vessel shall have a class surveyor attend vessel and survey the material condition of the shell plating and structural members in way of the insets located in the aft steering compartment and provide a class report attesting to the same. 74 SOLAS (14) I/11(a)
Action required: 705 - Other - as specified
Due 5 September 2019
Resolved 29 August 2019
Resolution: Affected area found structurally sound with no damage to frames. A suitable condition of class has now been imposed for permanent repairs to be carried out.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 16 June 2019 Resolved
Every lifeboat shall be powered by a compression-ignition engine. Vessel's port side lifeboat engine has been removed for overhaul at a repair facility in Houston, TX. Vessel is required to install and test lifeboat engine to the satisfaction of CG Marine Inspector prior to departure from Houston during its July 2019 port call.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 August 2019
Resolution: Rcvd class report and it has been accepted. See documents for more details.
Engineering › Diesel Engine (propulsion-direct drive) › Blower, Centrifugal
Issued 9 March 2017 Resolved
Vessel's auxiliary main engine air blower is inoperable. Docking assist tugs required to standby the vessel for immediate assistance prior to transiting across the Hampton Roads Bridge Tunnel.
Action required: 705 - Other - as specified
Due 9 March 2017
Resolved 5 April 2017
Resolution: Vessel submitted a class report attesting to newly installed blower.
Engineering › Freshwater System (cylinder head cooling) › Pump
Issued 4 August 2016 Resolved
Prior to the vessel's departure from Port of NY/NJ provide to the USCG Sector New York a report from your Authorized Classification Society that 1. All High Temperature Cooling Pumps are operational. 2. All required ballast pumps are installed and operational.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 5 August 2016
Resolved 13 August 2016
Resolution: Vessels Class soceity issued a condition of class to replace the damaged pump by 31 OCT 2016.
Deck/Cargo › Cargo Stowage › General
Issued 16 June 2016 Resolved
Cracks in cargo hold #3, bottom deck, Bay 14, in way of port tunnel and propagating into vertical structural member. Make repairs to the satisfaction of Class Society surveyor and provide written documentation of the same to the CG.
Action required: 17 - Rectify deficiencies prior to departure
Due 17 June 2016
Resolved 17 June 2016
Resolution: Received report from Lloyds surveyor that the repair is acceptable.
Operations/Management › Vessel Safety Management › External Certification/Verification/Control
Issued 3 February 2016 Resolved
Complete SMS audit. Focusing solely on the documents and data control section of the SMS.
Action required: 705 - Other - as specified
Due 13 May 2016
Resolved 16 June 2016
Resolution: Audit conducted by ABS. No non-conformities noted.
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 3 February 2016 Resolved
Replace both expansion joints and all 4 SSDG's. For a total of 08 expansion joints replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 April 2016
Resolved 24 March 2016
Resolution: Attending Coast Guard Marine Inspectors observed new expansion joints installed (4 per SSDG). Ship's crew had replaced all non-metallic expansion joints for all SSDGs, 16 in total.
Engineering › Fuel Oil Service System › Piping
Issued 3 February 2016 Resolved
Replace all oil soaked and worn lagging throughout the F/O purifier room.
Action required: 705 - Other - as specified
Due 1 April 2016
Resolved 30 March 2016
Resolution: Visually inspected lagging templates at 25% installation and received photographs of completed work.

Ownership record