MAURY USCG vessel records Sign in
← All vessels

ALEJANDRO B

ALEJANDRO B is a 2007 tank ship. The Coast Guard has recorded 25 inspections since 2007, most recently in June 2026, along with 8 deficiencies and 5 operational controls.

Records from 2007 to 2026. Most recent: inspection, 24 June 2026.

Built
2007
Last inspected
24 June 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9328285 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
904470
Flag
LIBERIA
—
Maury page id
psix-904470

Inspections, by type

…with no type recorded6
Years with a record 12 calendar years (2007–2026)
The 25 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it27916 - Convention (Subpart B), Gross Ton
13081 - Convention (Subpart B), Net Ton
47786 - Dead Weight, Ton
9686 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 25

24 June 2026 Administrative Inspection · PSC B · COC-CHEM & TVE Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8408291
19 May 2026 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8376581
23 August 2025 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8216091
2 July 2025 COC-CHEM & TVE Annual · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8167905
19 March 2025 Deficiency Check
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8096222
15 June 2024 PSC B · COC-CHEM & TVE Renew · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7935295
12 June 2023 COC-CHEM & TVE Annual · PSC B
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7712728
19 May 2023 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7691860
15 December 2022 Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7609735
9 November 2022 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7592207
26 July 2022 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7516785
11 June 2022 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7474237
11 June 2022 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7474286
9 June 2022 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7472795
26 January 2020 PSC B · COC-CHEM & TVE Renew
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6891299
21 October 2019 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6838454
4 December 2018 ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Annual · PII Safety Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6589506
14 November 2017 Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6306376
17 October 2014 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5006812
4 June 2014 ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4875037
11 April 2008 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3182122
16 December 2007 Administrative Inspection · MARPOL Annex II Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3116403
21 July 2007 ISPS II Exam · Ballast Water Examination · COC-CHEM Renew · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2998019
20 July 2007 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2998588
20 July 2007 Type not recorded
No type recorded · Station Mayport · USCG Southeast District (CGD-SE) · Activity 3002121

Deficiency record · 8

08 - Alarms › N/A - No Subsystem › Inert gas alarm
Issued 26 June 2024 Resolved
The alarms required in paragraphs 2.2.4.5.1.1, 2.2.4.5.1.3, and 2.2.4.5.1.5 shall be fitted in the machinery and cargo control room, where provided, but in each case in such a postion that they are immediately recieved by responsible members of the crew. PSCO observed absence of audible and visual alarms for the inert gas panel located in the CCR. 74 SOLAS (2004) II-2/4.5.5.1.1 FSS 2.2.4.5.2
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 19 March 2025
Resolution: Received Master/CE attestation that corrective action was taken and alarms were tested and fully functional. Also, observed email from Class that matter was resolved.
01 - Certificates & Documentation › 013 - Documents › Cargo information
Issued 26 June 2024 Resolved
Detailed instruction manuals shall be provided on board, covering the operations, safety and maintenence requirements and occupational health hazards relevant to the inert gas system and its operation to cargo tank system. The manuals shall include guidance on procedures to be followed in the event of fault or failure of the inert gas system. PSCO observed vessels IGG operation manual indicates the main control panel is located in the engine control room, however, the main control panel is located near the IGG near the upper platform of the engine room. Additionally, PSCO observed modifications to the systems. The CCR panel now contains a 3 pen digital recorder where the IGG operations manual mentions a 2 pen recorder. 74 SOLAS (2004) II-2/4.5.5.1.1 FSS 2.2.5
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 21 March 2025
Resolution: IGG manual was updated to refelct correct uses of the items provided. In addition, the location of the Main Control Panel has been updated. Both updates were verified, signed, and stamped by the attending class surveyor.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 26 June 2024 Resolved
Electrical equipment, cables, and wiring shall not be observed in the hazardous areas, unless it conforms with the standards not inferior to these acceptable to the Organization. PSCO observed a fault on the 5P isolation barrier for the Kongsberg tank radar system. The crew is unable to identify the cause of the fault. 74 SOLAS (2020) VII/10.1 IBC 10.1.4
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 June 2024
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 January 2020 Resolved
Ship must have a high level alarm that gives an audible and visual alarm before the tank reaches 97%. The visual alarm from the deck is not operational. Prior to loading cargo, the alarm must be operational in the United States. 46CFR153.409
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 February 2020
Resolved 27 January 2020
Resolution: Cleared.
Operations/Management › Pollution › Changeover Not Completed Prior to ECA
Issued 4 June 2014 Resolved
2470-Notification-While ships are operating within an ECA, the sulfur content used onboard shall not exeed 1%. The PSCO discovered the vessel has been operating within the North American ECA from 06/02/2014 to 06/04/2014 utilizing fuel oil that does not comply with MARPOL Annex VI ECA sulfur limits.-MARPOL/VI.14.4
Action required: 17 - Rectify deficiencies prior to departure
Due 6 June 2014
Resolved 5 June 2014
Resolution: Received, reviewed and accepted bunker delivery note of 300.06 metric tons of low sulfur (.979% sulfur) fuel oil to the vessel dated 04JUN14 from J.W. Stone Oil Distributer. Also received engineer log of change over procedure commencing at 1900 04JUN14.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 4 June 2014 Resolved
0611-Lifeboat Inventory-All life-saving appliances shall be in working order and ready for immediate use. Nine of the vessel's 34 food rations were not air-tight. Expiration of all food rations is June 2014. Vessel has ordered food rations for this port. Provide proof of receipt no later than 06/06/2014.-SOLAS(09 ConEd) III/20.2
Action required: 705 - Other - as specified
Due 6 June 2014
Resolved 5 June 2014
Resolution: Received, reviewed and accepted receipt of 35 food rations from Gulf States Marine Supply to the vessel with an expiration date of January 2018.
Deck/Cargo › Holds/Tanks › Portable Gas Measuring Equipment
Issued 4 June 2014 Resolved
1840-Instrumentation-Tankers shall be equipped with at least one portable instrument for measuring flammable vapor concentrations. Suitable means shall be provided for the calibration of such instruments. Vessel does not have means to calibrate portable gas detection meters. Vessel has ordered gas for calibration for this port. SOLAS (09ConEd) II-2/4.5.7.1
Action required: 705 - Other - as specified
Due 6 June 2014
Resolved 5 June 2014
Resolution: Recieved, reviewed and accepted reciept and pictures of calibration gas to the vessel from Gulf State Marine Supply.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 16 December 2007 Resolved
Make repairs to the oily water separator oil content meter. Meter does not report as required by MEPC (107). Meter does not read the number '0' during the clean water test. Until corrected, oil residues to be retained on board for discharge ashore. Deficiency is to be rectified prior to next US port after sailing foreign to the satisfaction of Class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 31 December 2007
Resolution: The measuring cell for the oil content meter was cleaned and system function tested satisfactory in the presence of DNV surveyer.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.