MAURY USCG vessel records
← All vessels

ALEJANDRO B

ALEJANDRO B is a 2007 tank ship. The Coast Guard has recorded 18 inspections since 2017, most recently in June 2026, along with 4 deficiencies and 3 operational controls.

Records from 2017 to 2026. Most recent: inspection, 24 June 2026.

Built
2007
Last inspected
24 June 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 24 June 2026
…with no type recorded4
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2017–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9328285
904470
Flag
LIBERIA
Maury page id
psix-904470

Documentation record

Tonnage as PSIX records it27916 - Convention (Subpart B), Gross Ton
13081 - Convention (Subpart B), Net Ton
47786 - Dead Weight, Ton
9686 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

18 inspections, each with its date, unit and type; 4 deficiencies with the resolution recorded against each; 3 operational controls with the dates imposed and removed; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 18

24 June 2026 Administrative Inspection · PSC B · COC-CHEM & TVE Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8408291
19 May 2026 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8376581
23 August 2025 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8216091
2 July 2025 COC-CHEM & TVE Annual · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8167905
19 March 2025 Deficiency Check
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8096222
15 June 2024 PSC B · COC-CHEM & TVE Renew · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7935295
12 June 2023 COC-CHEM & TVE Annual · PSC B
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7712728
19 May 2023 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7691860
15 December 2022 Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7609735
9 November 2022 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7592207
26 July 2022 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7516785
11 June 2022 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7474237
11 June 2022 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7474286
9 June 2022 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7472795
26 January 2020 PSC B · COC-CHEM & TVE Renew
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6891299
21 October 2019 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6838454
4 December 2018 ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Annual · PII Safety Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6589506
14 November 2017 Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6306376

Deficiency record · 4

08 - Alarms › N/A - No Subsystem › Inert gas alarm
Issued 26 June 2024 Resolved
The alarms required in paragraphs 2.2.4.5.1.1, 2.2.4.5.1.3, and 2.2.4.5.1.5 shall be fitted in the machinery and cargo control room, where provided, but in each case in such a postion that they are immediately recieved by responsible members of the crew. PSCO observed absence of audible and visual alarms for the inert gas panel located in the CCR. 74 SOLAS (2004) II-2/4.5.5.1.1 FSS 2.2.4.5.2
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 19 March 2025
Resolution: Received Master/CE attestation that corrective action was taken and alarms were tested and fully functional. Also, observed email from Class that matter was resolved.
01 - Certificates & Documentation › 013 - Documents › Cargo information
Issued 26 June 2024 Resolved
Detailed instruction manuals shall be provided on board, covering the operations, safety and maintenence requirements and occupational health hazards relevant to the inert gas system and its operation to cargo tank system. The manuals shall include guidance on procedures to be followed in the event of fault or failure of the inert gas system. PSCO observed vessels IGG operation manual indicates the main control panel is located in the engine control room, however, the main control panel is located near the IGG near the upper platform of the engine room. Additionally, PSCO observed modifications to the systems. The CCR panel now contains a 3 pen digital recorder where the IGG operations manual mentions a 2 pen recorder. 74 SOLAS (2004) II-2/4.5.5.1.1 FSS 2.2.5
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 21 March 2025
Resolution: IGG manual was updated to refelct correct uses of the items provided. In addition, the location of the Main Control Panel has been updated. Both updates were verified, signed, and stamped by the attending class surveyor.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 26 June 2024 Resolved
Electrical equipment, cables, and wiring shall not be observed in the hazardous areas, unless it conforms with the standards not inferior to these acceptable to the Organization. PSCO observed a fault on the 5P isolation barrier for the Kongsberg tank radar system. The crew is unable to identify the cause of the fault. 74 SOLAS (2020) VII/10.1 IBC 10.1.4
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 June 2024
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 January 2020 Resolved
Ship must have a high level alarm that gives an audible and visual alarm before the tank reaches 97%. The visual alarm from the deck is not operational. Prior to loading cargo, the alarm must be operational in the United States. 46CFR153.409
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 February 2020
Resolved 27 January 2020
Resolution: Cleared.

Ownership record