MAURY USCG vessel records
← All vessels

ADRI LAB

ADRI LAB is a 2007 passenger vessel (inspected). The Coast Guard has recorded 16 inspections since 2016, most recently in October 2025, along with 6 deficiencies.

Records from 2016 to 2025. Most recent: inspection, 6 October 2025.

Built
2007
Last inspected
6 October 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 6 October 2025
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDF2836
905507
Flag
UNITED STATES
Maury page id
psix-905507

Documentation record

Registered dimensions (L × B × D)145.4 ft × 30.0 ft × 12.3 ft
Registered tonnagegross 98 / net 67
ITC dimensions (L × B × D)145.4 ft × 30.0 ft × 12.3 ft
ITC tonnagegross 338 / net 101
BuilderBREAUX BROTHERS ENT. INC. · LOREAUVILLE, LA, UNITED STATES · built 2007
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portCHALMETTE, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 5 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it98 - Regulatory (Subpart C or D), Gross Ton
338 - Convention (Subpart B), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
101 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

16 inspections, each with its date, unit and type; 6 deficiencies with the resolution recorded against each; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 16

6 October 2025 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8246919
14 August 2025 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8210176
14 April 2025 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8111712
23 September 2024 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8007543
13 October 2023 Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7808127
20 August 2023 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7772636
15 July 2022 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7506017
25 August 2021 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7295526
9 August 2021 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7281257
22 October 2020 Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7083091
9 August 2019 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6777606
30 July 2019 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6767287
25 October 2018 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6568091
24 July 2017 Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6219142
24 July 2017 Administrative Inspection · COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6219209
7 November 2016 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6036837

Deficiency record · 6

07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 6 October 2025 Resolved
An interconnected detection and alarm system must be installed in each space that crew has routine access including accommodation spaces. Detection was installed in each individual crew state room, but did not have audible and visible alarms. Install audible and visible alarms in each crew state room. 46 CFR 181.450 46 CFR 181.405(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 November 2025
Resolved 5 November 2025
Resolution: Interconnected fire detection installed in all required areas.
05 - Radio Communications › N/A - No Subsystem › MF Radio installation
Issued 15 July 2022 Resolved
Be equipped with an MF-DSC radiotelephone transmitter and receiver meeting the requirements of paragraph (a)(2) of this section. Vessel did not have an MF-DSC radiotelephone on board for inspection. 47 CFR 80.905(a)(3)(ii)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2022
Resolved 22 June 2023
Resolution: Installed MF/HF Radio
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 25 August 2021 Resolved
Upon inspection of floating water lights, inspection found expired batteries.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 25 August 2021
Resolved 25 August 2021
Resolution: All floating light batteries replaced and tested.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 August 2019 Resolved
At each initial and subsequent inspection for certification of a vessel the owner or managing operator shall be prepared to conduct test and have the vessel ready for inspection of machinery, fuel and piping systems; Vsl fuel piping damaged and did not meet requirements set out in 46CFR176.804(e); Make repairs to meet requirements in 46CFR176.804(e); To the satisfaction of the Coast Guard; Prior to vsl's departure.
Action required: 17 - Rectify deficiencies prior to departure
Due 9 August 2019
Resolved 9 August 2019
Resolution: Vsl made repairs.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 9 August 2019 Resolved
A self-propelled vsl of 65 feet or more in length must have a properly installed, operational AIS; Vsl AIS was not operational; Make repairs to AIS meeting requirements IAW 33CFR164.46; To the satisfacion of the Coast Guard; Prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Due 9 August 2019
Resolved 9 August 2019
Resolution: Vsl has tech test, asses and make repairs to make AIS fully operational
Communications › Radio Communications › VHF Radiotelephone
Issued 7 November 2016 Resolved
Digital Selective Calling was not functioning on VHF radio.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 December 2016
Resolved 7 November 2016
Resolution: DSC is installed and functioning.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.