Records from 2008 to 2025. Most recent: inspection, 6 October 2025.
Documentation record
Registered dimensions (L × B × D)145.4 ft × 30.0 ft × 12.3 ft
Registered tonnagegross 98 / net 67
ITC dimensions (L × B × D)145.4 ft × 30.0 ft × 12.3 ft
ITC tonnagegross 338 / net 101
BuilderBREAUX BROTHERS ENT. INC. · LOREAUVILLE, LA, UNITED STATES · built 2007
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portCHALMETTE, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 5 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it98 - Regulatory (Subpart C or D), Gross Ton
338 - Convention (Subpart B), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
101 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 25
6 October 2025
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8246919
14 August 2025
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8210176
14 April 2025
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8111712
23 September 2024
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8007543
13 October 2023
Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7808127
20 August 2023
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7772636
15 July 2022
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7506017
25 August 2021
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7295526
9 August 2021
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7281257
22 October 2020
Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7083091
9 August 2019
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6777606
30 July 2019
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6767287
25 October 2018
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6568091
24 July 2017
Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6219142
24 July 2017
Administrative Inspection · COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6219209
7 November 2016
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6036837
23 July 2015
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5193579
21 July 2015
Internal Structural Exam · Hull Examination · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5202146
2 December 2011
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4200279
29 August 2011
Deficiency Check · Hull Examination · Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4130069
12 August 2011
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4112632
2 December 2010
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3902626
12 December 2008
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3378873
10 December 2008
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3378771
11 September 2008
Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3330244
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 6 October 2025
Resolved
An interconnected detection and alarm system must be installed in each space that crew has routine access including accommodation spaces.
Detection was installed in each individual crew state room, but did not have audible and visible alarms. Install audible and visible alarms in each crew state room.
46 CFR 181.450
46 CFR 181.405(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 November 2025
Resolved 5 November 2025
Resolution: Interconnected fire detection installed in all required areas.
05 - Radio Communications › N/A - No Subsystem › MF Radio installation
Issued 15 July 2022
Resolved
Be equipped with an MF-DSC radiotelephone transmitter and receiver meeting the requirements of paragraph (a)(2) of this section. Vessel did not have an MF-DSC radiotelephone on board for inspection. 47 CFR 80.905(a)(3)(ii)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2022
Resolved 22 June 2023
Resolution: Installed MF/HF Radio
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 25 August 2021
Resolved
Upon inspection of floating water lights, inspection found expired batteries.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 25 August 2021
Resolved 25 August 2021
Resolution: All floating light batteries replaced and tested.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 August 2019
Resolved
At each initial and subsequent inspection for certification of a vessel the owner or managing operator shall be prepared to conduct test and have the vessel ready for inspection of machinery, fuel and piping systems; Vsl fuel piping damaged and did not meet requirements set out in 46CFR176.804(e); Make repairs to meet requirements in 46CFR176.804(e); To the satisfaction of the Coast Guard; Prior to vsl's departure.
Action required: 17 - Rectify deficiencies prior to departure
Due 9 August 2019
Resolved 9 August 2019
Resolution: Vsl made repairs.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 9 August 2019
Resolved
A self-propelled vsl of 65 feet or more in length must have a properly installed, operational AIS; Vsl AIS was not operational; Make repairs to AIS meeting requirements IAW 33CFR164.46; To the satisfacion of the Coast Guard; Prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Due 9 August 2019
Resolved 9 August 2019
Resolution: Vsl has tech test, asses and make repairs to make AIS fully operational
Communications › Radio Communications › VHF Radiotelephone
Issued 7 November 2016
Resolved
Digital Selective Calling was not functioning on VHF radio.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 December 2016
Resolved 7 November 2016
Resolution: DSC is installed and functioning.