BERMUDA ISLANDER

BERMUDA ISLANDER is a freight ship. The Coast Guard has recorded 53 inspections since 2007, most recently in April 2026, along with 21 deficiencies and 9 operational controls.

Records from 2007 to 2026. Most recent: inspection, 13 April 2026.

Built
Not recorded
Last inspected
13 April 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9234434 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
905735
Flag
NETHERLANDS
—
Maury page id
psix-905735

Inspections, by type

…with no type recorded14
Years with a record 17 calendar years (2007–2026)
The 53 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it2937 - Convention (Subpart B), Gross Ton
1444 - Convention (Subpart B), Net Ton
3700 - Dead Weight, Ton
5603 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 53

13 April 2026 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8346812
9 October 2025 Deficiency Check · PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8249856
31 March 2025 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8102294
30 September 2024 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8011452
23 September 2024 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8007513
20 May 2024 Deficiency Check · In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7916121
1 April 2024 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7887912
11 September 2023 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7789233
14 August 2023 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7768732
27 February 2023 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7642397
8 August 2022 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7527742
24 January 2022 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7384477
20 July 2021 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7261809
8 February 2021 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7137264
9 August 2020 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7027700
20 July 2020 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7010970
27 January 2020 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6896599
11 August 2019 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6779321
6 August 2019 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6774855
13 May 2019 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6682752
22 April 2019 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6667457
23 May 2018 Deficiency Check · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6421812
14 May 2018 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6414437
8 May 2018 Ballast Water Examination · ISPS II Exam · NPV Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6408798
6 May 2018 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6464578
30 October 2017 Deficiency Check · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6297517
11 September 2017 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6264042
11 September 2016 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5997758
5 September 2016 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5995132
1 July 2016 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5925621
23 May 2016 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5884029
16 May 2016 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5878826
25 April 2016 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5861665
20 October 2015 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5746510
20 October 2015 PI Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5746743
20 October 2015 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5748677
25 August 2015 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5225644
25 August 2015 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5225999
26 October 2014 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5012544
13 June 2014 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4887607
9 January 2012 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4221695
18 April 2009 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3419519
21 February 2009 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3421582
13 October 2008 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3344457
6 October 2008 Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3339358
26 May 2008 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3217704
20 May 2008 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3212022
18 May 2008 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3210412
18 May 2008 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3211139
26 April 2008 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3192939
5 November 2007 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3093114
15 October 2007 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3080553
21 July 2007 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3002195

Deficiency record · 21

15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 9 October 2025 Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations. PSCO observed a lack of procedures related to the testing methodology for fire detectors. Request internal ISM audit within 90 days for the purpose of establishing fire detector testing methodology. 74SOLAS(20)IX/3.1 ISM Code 10.1
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2026
Resolved 28 October 2025
Resolution: Received class report (BV) attesting that vessel's company establshed procedures that describe how fire detector testing is conducted and the equipment to be used.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 23 September 2024 Resolved
Rescue boats shall be in a state of continuous readiness for launching in not more than 5 minutes. PSCO observed crew unable to start engine.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 September 2024
Resolved 23 September 2024
Resolution: Fuel line on rescue boat engine replaced. Engine in good standing order.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 May 2024 Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIII FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ONBOARD. PSCO RECEIVED NOTIFICATION THE VESSEL EXPERIENCED ISSUES WITH ITS MAIN ENGINE DUE TO UNKNOWN CAUSES.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 May 2024
Resolution: CLASS ATTENDED THE VESSEL AND ATTESTED TO THE PROPER OPERATION OF THE MAIN ENGINE
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 11 September 2023 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. PSCO observed temporary pneumatic pump hooked up directly to sludge pump. C/E stated sludge pump was inoperable and pneumatic pump is being used to operate sludge pump when sludge is being transferred. 74 SOLAS (20) I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 September 2023
Resolved 24 September 2023
Resolution: Received class report attesting to repairs. New sludge pump installed of same kind with satisfactory operational test.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 11 September 2023 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. PSCO found automatic fire damper for separator room to be inoperable. C/E was able to manually open and close damper from outside the space. 74 SOLAS (20) I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 September 2023
Resolved 24 September 2023
Resolution: Received class report attesting to repairs. Fire damper dissembled and grease during reassembly. Automatic switch renewed with satisfactory operational test.
Engineering › Steering Gear System › Pump
Issued 8 May 2018 Resolved
1030 - Steering gear alarm - Where the main steering gear comprises two or more identical power units, an auxiliary steering gear need not be fitted, provided that:... the main steering gear is arranged that a single failure in its piping system or in one of the power units the defect can be isolated so that steering capability can be maintained or speedily regained. A hydraulic locking alarm is sounding on the number one steering pump during its use. - 74 SOLAS (04) II-1/29.6.1.3
Action required: 17 - Rectify deficiencies prior to departure
Due 8 May 2018
Resolved 8 May 2018
Resolution: Received Class Survey Report and Technician Report. Reports are attached.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 8 May 2018 Resolved
0190 - Ship's logbooks/compulsory entries - The garbage record book... shall be in the form specified in the appendix to this annex. The vessel does not have a garbage record book following hte new appendix II standards detailed in Resolution MEPC.277(70). MARPOL V/10.3
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2018
Resolved 23 May 2018
Resolution: Vessel is in possession of the proper oil record book.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 8 May 2018 Resolved
2120 - Garbage - The entry for each discharge... shall include date and time, position of the ship, category of the garbage and the estimated amount discharged. Port State Control Officers found that garbage of multiple categories were logged together. MARPOL V/10.3.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2018
Resolved 23 May 2018
Resolution: The vessel is making proper entries in the garbage record book in accordance with MARPOL V/10.3.2.
Documentation › Markings/Placards › Oil Discharge Placard
Issued 8 May 2018 Resolved
9900 - Other (clearly not hazardouos) - A ship... must have a placard... in a conspicuous place in each machinery space... stating the following: The Federal Water Pollution Control Act prohibits the discharge of oil or oily waste... No oil placard was found in the vessel's engine room. - 33 CFR 155.450
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2018
Resolved 23 May 2018
Resolution: Vessel posted discharged of oil prohibited placard in the machinery space.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 11 September 2017 Resolved
Port state control officers observed the emergency generator exhaust pipe has an exhaust leak to an extent which would endanger crewmembers working within the space. 74SOLAS(04)II-1/26.1
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 12 October 2017
Resolved 6 October 2017
Resolution: Recieved class report stating that the system has been properly repaired.
Construction/Loadline › Markings › Load Line Mark
Issued 11 September 2017 Resolved
Port state control officer observed summer load line marked Z, fresh water load line by a ZW, and tropical fresh water load line marked by a TZW, which do not corrispond with the marking required by the convention. ICLL 6.2(a)(b)
Condition: Improper Installation
Due 12 October 2017
Resolved 30 October 2017
Resolution: VESSEL SUBMITTED DOCUMENTATION FROM FLAG THAT IDENTIFIES THAT ACCORDING TO DUTCH LAW THEY ARE PERMITTED TO NOTATE ON LOAD LINE FOR SUMMER AS Z, FRESH WATER ZW, AND TROPICAL FRESH WATER TZW.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 11 September 2016 Resolved
Every life bouy shall be fitted with a grabline not less than 9.5mm in diameter and not less than 4 times the outer diameter of the bouy in length. PSCO identified 06 bouy grablines are dry-rotted. 01 of those life bouys is missing the vessel's name and port of registry according to 74 SOLAS (97) III/1.4.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 6 October 2016
Resolution: Vessel provided images showing all life bouys have the vessel's name and port of registry, and the grab lines have been changed. All corrections are to the satisfaction of the PSCO.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 25 April 2016 Resolved
Every company should develop, implement, and maintain a safety managment system which includes procedures for reporting accidents and non-conformities with the provisions of theis code. Master and Chief Engineer did not inform the company for vessel SMS 24.1. The company was not informed about a main engine fuel pump failure which caused the crew to shut the engine down at sea. External Audit rec.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 25 April 2016
Resolved 25 April 2016
Resolution: USCG recieved BV Class REP-NO NYK0/2016/J0071B stating that an ext audit would be conducted within 60 days.
Operations/Management › Vessel Safety Management › Master's Responsiblity/Authority
Issued 25 April 2016 Resolved
Company should ensure that the ship's personnel are able to communicate in the execution of their duties related to the safety management system. The Master and Chief Engineer could not effectively communicate their roles and responsibilities to PSCO pertaining to the reporting requirements for non-conformities.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 25 April 2016
Resolved 25 April 2016
Resolution: USCG recieved BV Class REP-NO NYK0/2016/J0071B stating that an ext audit would be conducted within 60 days.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 25 April 2016 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. PSCO observed an excessive amount of marine grade fuel oil in engine room bilge.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 25 April 2016
Resolved 25 April 2016
Resolution: USCG recieved BV Class REP-NO NYK0/2016/J0071B stating that the crew utilized a sandpiper to remove MGFO from bilges into the ship's DOT and ST.
Electrical › Electric Supply System (service) › Battery Charger
Issued 6 October 2008 Resolved
0830 Pipes wires- accident prevention - The battery charger for both the main generators were found to be OOC. A temporary arrangement with a portable battery charger was in its place with loose wire connections. Class sprayer to attest to proper arrangements of battery charging systems of both generators. SOLAS 04 ChII-1 Reg 26.1
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 7 October 2008
Resolved 13 October 2008
Resolution: Repaired to the satisfaction of attending Coast Guard PSCO''''''''s.
Electrical › Lighting (service) › Lighting Fixture
Issued 6 October 2008 Resolved
0830 pipes wires - accident prevention - Found a loose wire in the emergency generator room that had duck tape covering the exposed ends hanging on the foreword bulkhead, posing an electrical hazard. SOLAS 04 CH. II-1 Reg 45.1.3
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 7 October 2008
Resolved 13 October 2008
Resolution: Repaired to the satisfaction of attending Coast Guard PSCO''''s.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 6 October 2008 Resolved
0999 safety in general - Bilge and associated piping was observed to be coated in oil, identifying a lack of general house keeping.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 7 October 2008
Resolved 13 October 2008
Resolution: Cleaning completed to the satisfaction of attending Coast Guard PSCO''''s.
Personnel › Training › Familiarization Training
Issued 20 May 2008 Resolved
Gangway watch stander was unfamiliar with responsibilities of standing a security watch. He did not check ID's, and left the gangway without relief. Vessel must conduct training with all security watch standing crew members to ensure they are familiar with their security duties.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 27 May 2008
Resolved 26 May 2008
Resolution: Vessel conducted security training and 2 security drills. Gangway watchstander did check ID and was knowledgeable of the ships security procedures.
Engineering › Diesel Engine (propulsion-electric) › Injector (fuel injection)
Issued 20 May 2008 Resolved
Vessel suffered a high temp alarm and reduce power alarm inbound to sec-del bay
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 May 2008
Resolution: Received (BV) class surveyor report attesting to the repairs and replacement of the fuel injector adaptor and fuel injector on cylinder 6. Engine was ran tested at 700 rpms with no further problems.
Navigation › Piloting/Steering › Gyro Compass
Issued 26 April 2008 Resolved
Inoperable Gyrocompass.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 April 2008
Resolution: RCVD TECH REPORT

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.