Records from 2013 to 2025. Most recent: inspection, 30 September 2025.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Documentation record
Registered dimensions (L × B × D)66.0 ft × 25.0 ft × 7.0 ft
Registered tonnagegross 77 / net 61
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderRODRIGUEZ BOAT BUILDERS INC · CODEN, AL, UNITED STATES · built 2007
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portBELLE CHASSE, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 8 August 2025 · expires 31 August 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it77 - Simplified, Gross Ton
61 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 October 2025
Resolved
Portable fire extinguishers must be inspected, maintained, and tested in accordance with the inspection, maintenance procedures required by Chapters 7 & 8 of NFPA 10. Annual servicing for on board fire extinguishers was overdue.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 10 October 2025
Resolved 3 October 2025
Resolution: Certified technician conducted service on all fire extinguishers on board.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 September 2024
Resolved
Fire-detection systems must be inspected or tested at least once every 12 months. No records available for the servicing and maintenance of fire detection panel.
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Due 8 October 2024
Resolved 17 September 2024
Resolution: Received tech report for fire det panel. All sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 September 2024
Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards. There was excessive build up of oily dust on both generator windings.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 8 October 2024
Resolved 17 September 2024
Resolution: Received tech report clearning SSDG's. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 10 September 2024
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. MI found main switch board "power available" generator lights inoperable.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 October 2024
Resolved 18 September 2024
Resolution: Received pictures. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 10 September 2024
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. MI found 120-volt panel in the engine room (near main switch board) missing a blank.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 October 2024
Resolved 7 October 2024
Resolution: Received picture. All sat.
12 - Dangerous Goods › N/A - No Subsystem › Tank entry
Issued 10 September 2024
Resolved
Each towing vessel must be designed and operated so as to minimize fire hazards. MI found rubber hosing used on fuel sight glasses.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 October 2024
Resolved 17 September 2024
Resolution: Sight glass replaced with proper. All sat.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 10 September 2024
Resolved
Has installed, in the engine room and any other area where background noise makes a general alarm hard to hear, a supplemental flashing red light that is identified with a sign that reads: “Attention General Alarm—When Alarm Sounds or Flashes Go to Your Station”.
MI found no indication placard in E/R.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 October 2024
Resolved 18 September 2024
Resolution: Received pictures. All sat.
12 - Dangerous Goods › N/A - No Subsystem › Temperature control
Issued 10 September 2024
Resolved
Each exhaust pipe from an internal combustion engine which is within reach of personnel must be insulated or otherwise guarded to prevent burns. MI found missing exhaust heat wrap on both SSDG's, exhaust manifold to turbo charger.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 October 2024
Resolved 28 October 2024
Resolution: Received pictures of newly installed heat wrap. All sat.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 10 September 2024
Resolved
Emergency lighting must be provided for all internal crew working and living areas. (2) Non-electric, phosphorescent adhesive lighting strips that are installed along escape routes and sufficiently visible to enable egress with no power. MI found no Egress lighting in Bunk rooms.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 October 2024
Resolved 28 October 2024
Resolution: Received pictures of egress luminescent tape installed. All sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 September 2024
Resolved
The frame or support of any semi-portable fire extinguisher fitted with wheels must be welded or otherwise permanently attached to a steel bulkhead or deck to prevent it from rolling under heavy sea conditions. MI found Semi-Portable fire extinguisher not secured.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 October 2024
Resolved 11 September 2024
Resolution: All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 September 2024
Resolved
Relief valves must be tested in accordance with 46 CFR 143.245. MI found one relief valve (on each UPV) painted and unable to determine set pressure. The other relief valve (on each UPV) had not been tested since 2018.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 October 2024
Resolved 18 September 2024
Resolution: Reeived reports and pictures of new PRV's installed. All sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 10 September 2024
Resolved
A towing vessel subject to this subchapter and choosing the Coast Guard inspection options, or required to have the Coast Guard options, must undergo an annual inspection withing 3 months before or after the COI anniversary date. The vesse failed to undergo and Annual inspection within the required intervals.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 10 September 2024
Resolved 10 September 2024
Resolution: Completed annual inspection.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 7 July 2020
Resolved
Each towing vessel must have a fire-detection system installed to detect engine room fires. The owner or manager operator must ensure the following: (1)-(8). Vessels fire detection panel was inoperable and the crew was unsure how long but from 1 week to 4 weeks. Service, repair, or replace system to fully operational condition by a trained servicing technician to the satisfaction of the marine inspector.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 7 July 2020
Resolution: Received technican report from Eagle. System is fully functional and believed that it was damaged during some welding on the vessel.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Safety and environment policy
Issued 7 July 2020
Resolved
Personnel must meet the requiremetns in 15.405 and 15.1105 of this chapter as appropriate (b) prior to getting underway for the first time on a particular towing vessel, each crew member must receive a safety orientation on (1)-(10). Master and new deck hand had not completed new crew orientation. Master was unaware of the requirements. Provide training to all crew members and reach out to Sector New Orleans to schedule the follow up inspection within 14 days to complete COI application process.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 July 2020
Resolution: Verified crew orientation onboard the vessel and where it was logged.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Safety and environment policy
Issued 7 July 2020
Resolved
All crewmembers must be provided with health and safety inforamtion and training that includes:(1)-(9). Provide all crew with training on the health and safety information and plans on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 July 2020
Resolution: Verified crew training on board of the health and safety plan.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Masters responsibility and authority
Issued 7 July 2020
Resolved
Responsibilities of the master and crew. (a) The safety of the towing vessel is the responsibility of the master and include (1)-(4). Vessel master was unaware of safety and health plan, voyage planning, navigation assessments, safety orientation, and reporting procedures. Provide adequate trainiing to the master to the satisfaction of the marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 July 2020
Resolution: Company representive provided training for the master and marine inspectors verified training.