Records from 2008 to 2025. Most recent: inspection, 24 November 2025.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 24
24 November 2025
Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8269720
1 October 2025
Internal Structural Exam · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8239766
16 September 2024
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8003294
10 August 2024
Damage Survey · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7978490
10 August 2024
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7979673
6 March 2024
Type not recorded
No type recorded · Station Islamorada · USCG Southeast District (CGD-SE) · Activity 7875854
14 October 2023
COI Inspection · Examination of Repairs · Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7808360
5 January 2023
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7616673
9 December 2022
In-Service Inspection · Plan Review "T" Boat
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7607794
25 October 2022
Internal Structural Exam · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7583289
5 October 2022
In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7572306
1 September 2022
In-Service Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7548639
3 January 2022
Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7375032
29 September 2021
In-Service Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7323009
6 January 2021
DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7121156
15 October 2020
Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7081803
17 October 2019
DAPI Audit · Annual Inspection · Administrative Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6841344
3 October 2018
DAPI Audit · COI Inspection · Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6565563
22 February 2018
Administrative Inspection · DAPI Audit · Annual Inspection · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6555725
12 September 2017
Damage Survey
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6294323
9 February 2017
DAPI Audit · Deficiency Check · Internal Structural Exam · Administrative Inspection · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6085232
31 January 2017
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6085870
5 October 2016
Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6030892
2 February 2016
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5807733
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 24 November 2025
Resolved
Engine compartment high water alarm only has audible alarm and no visual alarm.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 November 2025
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 24 November 2025
Resolved
Distress signals need to be properly marked on container.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 November 2025
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 August 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to provide services necessary for safety under normal and emergency conditions and protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock.
Vessel suffered potential electrical fire in the engine compartment.
Identify source of potential electrical fire and affect permanent repairs to the satisfaction of a USCG Marine Inspector prior to the carriage of passengers.
46 CFR 183.200
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 September 2024
Resolution: Electrical harness has been replaced.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 10 August 2024
Resolved
A pre-engineered fixed gas fire extinguishing system must be approved by the Commandant and capable of manual actuation from outside the space in addition to automatic actuation by a heat detector.
The fixed gas fire extinguishing system is inoperable and is unable to be activated from outside the space.
The fixed fire extinguishing system shall be inspected and serviced. Provide technician report to the satisfaction of a USCG Marine Inspector prior to the carriage of passengers.
46 CFR 181.420(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 September 2024
Resolution: New remote cable has been installed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 August 2024
Resolved
Each portable fire extinguisher on a vessel must be of an approved type. The minimum number of portable fire extinguishers required on a vessel must be acceptable to the cognizant Officer in Charge, Marine Inspection.
One extinguisher was discharged and is no longer in serviceable condition.
Install new fire extinguisher to the satisfaction of a USCG Marine Inspector prior to the carriage of passengers.
46 CFR 181.500(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 September 2024
Resolution: Portable extinguisher has been replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 October 2023
Resolved
Make repairs to the life ring or replace life ring with CG approved life ring.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 November 2023
Resolved 27 October 2023
Resolution: Replaced with new life ring
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 14 October 2023
Resolved
Make repairs to all 3 bilge high water alarm visual indicators so they the light comes on with the alarm for each space.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 November 2023
Resolved 27 October 2023
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 14 October 2023
Resolved
Unable to conduct drills due to not enough crew. Must conduct drills once vessel is out of drydock and prior to operations after drydock inspection.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 November 2023
Resolved 27 October 2023
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 1 September 2022
Resolved
Inspected 03 fire buckets, 02 fire buckets found without lanyards. Add suitable length of line to reach water from the vessel's deck to the satisfaction of attending CG Marine Inspector prior to conducting passenger operations.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2022
Resolved 2 September 2022
Resolution: Attached lanyards to fire buckets
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 1 September 2022
Resolved
Tested all navigation lights, found stern/ anchor light and green Starboard side light extinguished. Red Port side light found operating intermittently. Service all navigation lights to the satisfaction of attending CG Marine Inspector prior to conducting passenger operations.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 September 2022
Resolved 2 September 2022
Resolution: Replaced bulbs in lights and fixed loose connection.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 3 January 2022
Resolved
Anchor/mast light was not working. Must conduct repairs prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 January 2022
Resolution: Fixed lose connection
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 January 2022
Resolved
Life ring was found with non SOLAS retro tape. Replace all retro with SOLAS retro tape.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 February 2022
Resolved 4 February 2022
Resolution: replaced all retro tape.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 3 January 2022
Resolved
Life float was found with non SOLAS faded/warn retro tape. Replace all retro with SOLAS retro tape.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 February 2022
Resolved 4 February 2022
Resolution: Replaced all retro tape
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 January 2022
Resolved
One adult life jacket was found in non servicable condition. Must replace and properly lable with vessels name. Passenger count reduced by one until cleared by CG.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 February 2022
Resolved 4 February 2022
Resolution: Bought new type 1 life jacket
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 3 January 2022
Resolved
First aid kit was found with expired items. Must replace all expired items.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 February 2022
Resolved 4 February 2022
Resolution: Replaced all expired items in first aid kit
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 3 January 2022
Resolved
MDE guard was missing. Must replace missing MDE guard.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 February 2022
Resolved 4 February 2022
Resolution: Re installed engine guard
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 29 September 2021
Resolved
Vessel is required to have 12 flares, minimum 6 red. Vessel only had 6 orange flares with experation date of 2023. Must replace missing 6 red flares.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 September 2021
Resolved 8 October 2021
Resolution: 12 brand new flares were placed onboard the vessel
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 6 January 2021
Resolved
Logs for fire drill, MOB and crew training were not onboard vessel and left inside the shop. Must provide proof of all training as required
46 CFR 185.520
46 CFR 185.524
46 CFR 185.420
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 February 2021
Resolved 5 February 2021
Resolution: Received email with pictures of all new logs and logging all required info
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 6 January 2021
Resolved
Vessel did not have a papar chart onboard and current software verson on GPS is 11.0. Garmin shows for that perticular GPS, most recent verson is 21.0. Must update GPS to current software verson or buy new approve NAV Chart
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 February 2021
Resolved 5 February 2021
Resolution: received email with pictures showing his GPS was updated to the latest software version according to Garmin website
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 January 2021
Resolved
3 adult life jackets were found in non usuable condition. 2 child life jackets need retro tape replaced. Reduce passenger count by 3 adults until replacements are on board.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 February 2021
Resolved 8 January 2021
Resolution: Bought 3 new adult life jackets and labeled with vessels name. 2 child life jackets had retro replaced. All SAT
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 January 2021
Resolved
All 3 bilge pumps work, but the visual indicators on the helm station do not work. Must replace all 3 indicators on helm station and test to satisfaction on attending CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 February 2021
Resolved 5 February 2021
Resolution: Received video of all 3 bilge visual indicators working.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 15 October 2020
Resolved
Starboard side forward of the engine bay outboard stringer masked with red, needs grinding down and reglassed.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 November 2020
Resolved 28 October 2020
Resolution: Marked stringer was grinded back to structured wood and reglassed.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 17 October 2019
Resolved
Renew port side light lens or bulb.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 October 2019
Resolution: Port side light has been renewed and corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 October 2019
Resolved
Bilge auto operation visual indicators are extinguished. Repair/renew
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 October 2019
Resolution: Visual indicator for automatic bilge operations has been replaced and have been operationally verified.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 October 2019
Resolved
Renew missing items in First Aid Kit.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 October 2019
Resolution: First aid kit has been renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 October 2018
Resolved
1 adult PFD is no longer servicable. Renew.
Action required: 10 - Deficiency Rectified
Resolved 22 October 2018
Resolution: New PFD was placed onboard.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 22 October 2018
Resolved
FCC safety radio certificate is expired. Renew.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 October 2018
Resolution: New certificate was provided.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 22 October 2018
Resolved
Engine room and aft compartment high level visual alarms are extinguished. Repair/renew.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 October 2018
Resolution: Visual alarm bulbs were renewed, and tested all sat.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 22 October 2018
Resolved
Bilge pumps do not send a visual alarm while in automatic operation. Install new visual indicators.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 October 2018
Resolution: LED lights have been installed and tested all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 22 October 2018
Resolved
Life float has numerous tears, netting is failing and grab lines are wasted. Renew life float.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 October 2018
Resolution: New life float was installed.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 9 February 2017
Resolved
Vessel COD has expired and must be renewed prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 February 2017
Resolution: O/O renewed COD, and had it expedited. Recieved conformation that COD was renewed.
Lifesaving › Lifebuoys › Serviceable
Issued 9 February 2017
Resolved
Life ring is no longer serviceable, and must be renewed.
Action required: 705 - Other - as specified
Due 23 February 2017
Resolved 28 February 2017
Resolution: New Life ring was provided, and marked.
Lifesaving › Lifefloat › Retroreflective Material
Issued 9 February 2017
Resolved
Life float has significant sun damage and needs new reflective tape.
Action required: 705 - Other - as specified
Due 23 February 2017
Resolved 28 February 2017
Resolution: Life float was repaired and new reflective tape was installed.
Engineering › Fuel Oil Service System › Filter
Issued 9 February 2017
Resolved
Racor Fuel Filter is missing the flame impingement bowl. Repair or replace.
Action required: 705 - Other - as specified
Due 23 February 2017
Resolved 28 February 2017
Resolution: New fuel filter bowl was installed.