MAURY USCG vessel records
← All vessels

DOLPHINS DOWN UNDER II

DOLPHINS DOWN UNDER II is a 2007 passenger vessel (inspected). The Coast Guard has recorded 18 inspections since 2016, most recently in May 2026, along with 22 deficiencies and 2 casualty investigations between 2013 and 2014.

Records from 2013 to 2026. Most recent: inspection, 5 May 2026.

Built
2007
Last inspected
5 May 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 5 May 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDD9756
908311
Flag
UNITED STATES
Maury page id
psix-908311

Documentation record

Registered dimensions (L × B × D)45.0 ft × 14.0 ft × 3.5 ft
Registered tonnagegross 11 / net 11
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCORINTHIAN CATAMARANS LLC · TARPON SPRINGS, FL, UNITED STATES · built 2007
Hull materialFRP (Fiberglass)
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationTwin Hull
Hailing portORANGE BEACH, AL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 4 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it11 - Simplified, Gross Ton
11 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

18 inspections, each with its date, unit and type; 22 deficiencies with the resolution recorded against each; 2 casualty investigations, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 18

5 May 2026 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8344237
6 March 2026 Drydock Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8320837
7 April 2025 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8106791
1 April 2024 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7896469
14 February 2024 Administrative Inspection · Hull Examination · Drydock Exam · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7865615
1 May 2023 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7678649
18 April 2022 COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7434680
1 February 2022 Administrative Inspection · Deficiency Check · Hull Examination · Examination of Repairs · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7388916
5 May 2021 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7190030
7 May 2020 Administrative Inspection · Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6949665
7 February 2020 Hull Examination · Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6904654
3 May 2019 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6676297
20 March 2018 Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6375453
20 March 2018 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6384991
20 June 2017 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6184484
24 March 2017 DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6110845
27 April 2016 Administrative Inspection · Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5863901
22 February 2016 Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5819928

Deficiency record · 22

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 6 March 2026 Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel next scheduled dry dock is past due.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 March 2026
Resolution: Completed drydock.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 17 April 2024 Resolved
The medical certificate will be issued for various periods of time based upon the endorsements the mariner holds. Marine Inspector observed missing medical card for vessels Captain. Provide evidence of.
Action required: 705 - Other - as specified
Resolved 26 April 2024
Resolution: Vessel rep provided link to NVDIC showing a valid medical certificate. Marine Inspector reviewed and found satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 17 April 2024 Resolved
Gauges to indicate engine revolutions per minute, jacket water discharge temperature, and lubricating oil pressure must be provided for all propulsion engines. The gauges must be readily visible at the operating station. Marine Inspector observed gauges not reading while engines were running. Repair.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 April 2024
Resolution: Vessel rep supplied photographs of new working tachometers. Marine Inspector reviewed and found satisfactory.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 11 May 2023 Resolved
Each vessel certificated to operate on a limited coastwise route within three miles of land in warm water must: Have on board a FCC Type Accepted Category 1 406 MHz EPIRB, installed to automatically float free and activate, and not be required to carry survival craft.Vessel did not have a valid EPIRB on board IAW the vessels COI. Vessel is limited to 1 mile from shore until a valid EPIRB is installed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 May 2023
Resolved 5 June 2023
Resolution: Vessel rep. sent in an email stating he wishes to continue to operate per his COI and not go more than 1 mile from shore.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 April 2022 Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 1 inch high indicating purpose of the valve and direction of operation. Label for fuel shut off valve location was partially torn off. Replace label.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2022
Resolved 3 May 2022
Resolution: Releabled fuel shut off valve
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 April 2022 Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in each normally unmanned spaces. The high level visual alarm for the Port aft viewing box space was inoperable. Repair/replace.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2022
Resolved 3 May 2022
Resolution: replaced visual alarm light.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 June 2020 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in the electrical equipment, and electrical shock. Vessel had exposed wiring in port deck box above MSD tank, and in the midship starboard viewing tank near light fixture.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2020
Resolved 17 July 2020
Resolution: Vessel sent in satisfactory evidence of deficiency correction. Vessel properly secured deadend wires.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 23 June 2020 Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. Pendants on life float were secured with zip ties, secure with line or rubber band to make utilizing in emergency more effective.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2020
Resolved 17 July 2020
Resolution: Vessel sent in satisfactory evidence of deficiency correction. Vessel removed zip ties and replaced them with an easier means of undoing the life float pendants.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 23 June 2020 Resolved
Each life ring buoy must be marked with Type II retro-reflective material approved in 46 CFR 164.018. Vessel retro tape is worn and in need of replacement.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2020
Resolved 17 July 2020
Resolution: Vessel sent in satisfactory evidence of deficiency correction. Vessel replaced old worn out retro.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 May 2019 Resolved
02 fire buckets cracked; replace both fire buckets
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 June 2019
Resolution: Replaced fire buckets
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 21 May 2019 Resolved
06 orange smoke distress signals expired; replace.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 June 2019
Resolution: Replaced orange smoke distress signals
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 May 2019 Resolved
Ring buoy water light lanyard is approx. one ft in length. Replace with lanyard 3-6 feet long.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2019
Resolved 13 June 2019
Resolution: Replaced with 6 ft lanyard
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 23 April 2018 Resolved
All FCC documents need to be corrected and updated. The Call Sign and MMSI are incorrect.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2018
Resolved 25 April 2018
Resolution: O/O has attempted multiple times to update FCC document however the FCC has repeatedly informed the O/O that he no longer is required to maintain a Safety Radio Cert.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 23 April 2018 Resolved
Anchor light was in-op. Restricted the vessel to daylight and high visibility operations only.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 May 2018
Resolved 25 April 2018
Resolution: Recieved picture: ALL SAT
Lifesaving › Lifebuoys › Serviceable
Issued 11 May 2017 Resolved
Replace 01 retroreflective tape on lifebuoy. IAW 46 CFR 180.70.
Action required: 705 - Other - as specified
Due 12 June 2017
Resolved 19 June 2017
Resolution: Verified that retroreflective tape on 01 lfebouy was replaced.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 11 May 2017 Resolved
Life floats water light tether must be attached around the body of the float and be at least 18’ long. Each life float must be individually attached to the painter by a line long enough that each float can float without contacting each other. IAW 46 CFR 180.137/175.
Action required: 705 - Other - as specified
Due 12 June 2017
Resolved 19 June 2017
Resolution: Verified that water light tether was attached around the body of the life float and was atleast 18' long. Verified that each life float was individually attached to the painter by a line long enough that each float can float without contacting each other
Communications › Alarms/Indicators › High Water Alarm
Issued 11 May 2017 Resolved
Portside aft viewing port and port aft compartment bilge high water alarm visual and audible alarm needs to function properly. IAW 46 CFR 182.530.
Action required: 705 - Other - as specified
Due 12 June 2017
Resolved 19 June 2017
Resolution: Verified that aft viewing port and port aft compartment bilge high water alarm visual and audible alarm was functioning properly.
Communications › Radio Communications › VHF Radiotelephone
Issued 11 May 2017 Resolved
Install GPS and MMSI to VHF-DSC. IAW 46 CFR 184.502.
Action required: 705 - Other - as specified
Due 12 June 2017
Resolved 19 June 2017
Resolution: Verified that GPS and MMSI was installed to VHF-DSC.
Electrical › Electric Supply System (service) › Battery Installation
Issued 23 May 2016 Resolved
Replace connections on battery terminal with permanent type connectors IAW 46 CFR 183.350
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 May 2016
Resolved 24 May 2016
Resolution: Battery terminal connections made permanent.
Navigation › Piloting/Steering › Marine Charts
Issued 23 May 2016 Resolved
Marine Chart not up-to-date. Replace with updated chart IAW 46 CFR 184.420
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 May 2016
Resolved 24 May 2016
Resolution: Provided updated charts.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 23 May 2016 Resolved
Provide updated copy of Navigation Rules IAW 46 CFR 184.420
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 May 2016
Resolved 24 May 2016
Resolution: Purchased new copy of Nav Rules.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 23 May 2016 Resolved
Waterlight line was not sufficient. Replace with proper line IAW 46 CFR 180.70.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 May 2016
Resolved 8 June 2016
Resolution: Waterlight line given approval by OCMI.

Casualty record · 2

8 August 2013Routine · role: Involved in a Marine Casualty · activity 4690843