MAURY USCG vessel records
← All vessels

GONSOULIN 501

Built
2008
Last inspected
17 July 2023
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 17 July 2023
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2008–2023)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

908313
Flag
UNITED STATES
Maury page id
psix-908313

Documentation record

Registered dimensions (L × B × D)297.5 ft × 54.0 ft × 12.0 ft
Registered tonnagegross 1,619 / net 1,619
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLEBEOUF BROS TOWING LLC · BOURG, LA, UNITED STATES · built 2008
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeBox
Hull configurationMonohull
Hailing portHOUMA, LA
Endorsements, as the file codes themcw_un
DocumentationValid · issued 13 February 2026 · expires 31 March 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1619 - Simplified, Gross Ton
1619 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 17 inspections, each with its date, unit and type; 6 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 6 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 6

Inspection history · 17

17 July 2023 Administrative Inspection · COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7745092
5 June 2018 COI Inspection · Internal Structural Exam · Administrative Inspection · Cargo Tank Internal
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6434554
11 May 2018 Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6415071
23 January 2017 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6092950
5 July 2016 MTSA Verification · Periodic Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5930198
3 March 2015 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5089816
10 June 2014 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4986640
4 November 2013 Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 4747174
5 July 2012 Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4367947
29 May 2012 Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4327443
27 May 2012 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4349302
18 February 2012 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4249173
8 February 2012 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4263814
16 June 2009 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3505944
4 May 2009 Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3467078
12 December 2008 Damage Survey
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3379045
14 January 2008 Deadweight Survey · MTSA Verification · Initial Certification · Construction Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3129923

Deficiency record · 6

Engineering › Diesel Engine (propulsion-direct drive) › Seal
Issued 3 March 2015 Resolved
Found oil leak on generator engine
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 March 2015
Resolution: Leak corrected
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 3 March 2015 Resolved
Exhaust leak found on barge pump engine
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 March 2015
Resolution: Coupling replaced on engine
Electrical › Electrical Distribution System (service) › Junction Box
Issued 14 January 2008 Resolved
Provide seal into box for wiring harness on pump engin to meet class 1 / division 1 location.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 April 2008
Resolution: Wiring harness penetration was temporarily filled with putty until new harness can be installed.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 14 January 2008 Resolved
Gouge and reweld marked leaks in #1 port and #3 port cargo tanks.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 April 2008
Resolution: small holes were gouged and welded. Pictures were sent showing repair work done over the weekend.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 14 January 2008 Resolved
Provide Vessel Response Plan approval letter within 30 days. If not received, contact MSU Houma prior to 25 May 2008.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 May 2008
Resolved 4 May 2009
Resolution: Contacted vsl rep.
Documentation › Manuals/Policy Documentation › Operations Manual (Incinerator)
Issued 14 January 2008 Resolved
Vessel allowed to operate thermal fluid heater for 30 days pending approval of submitted procedures.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 May 2008
Resolved 4 May 2009
Resolution: Contacted vsl rep.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.