TAIGA DESGAGNES is a 2007 freight ship. The Coast Guard has recorded 20 inspections since 2016, most recently in January 2026, along with 4 deficiencies and 1 operational control.
Records from 2016 to 2026. Most recent: inspection, 23 January 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it12936 - Convention (Subpart B), Gross Ton 5824 - Convention (Subpart B), Net Ton 17286 - Dead Weight, Ton 24320 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 3 December 2025Resolved
GENERAL ARRANGEMENT OF PLANS SHALL BE PERMANENTALT EXHIBITED FOR THE GUIDANCE OF THE SHIPS OFFICERS, SHOWING CLEARLY FOR EACH DECK THE CONTROL STATIONS, THE VARIOUS FIRE SECTIONS ENCLOSED BY "A" CLASS DIVISIONS... PLANS AND BOOKLETS SHALL BE KEPT UP TO DATE, ANY ALTERATIONS THERETO SHALL BE RECORDED AS SOON AS PRACTICABLE.
PSCO OBSERVED A "B" CLASS DOOR WITHIN AN "A" CLASS BOUNDARY LADDERWELL. THE "B" CLASS DOOR IS NOT LISTED ON THE FIRE CONTROL PLAN.
74SOLAS(20) II-2/15.2.4.1
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 3 December 2025
Resolved 23 January 2026
Resolution: Vessel's company provided class survey statement and pictures sufficient to clear this deficiency. Vessel removed unapproved door and emptied space as per the ship's fire control plan.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 24 January 2023Resolved
CARGO SHIPS WHERE HORIZONTALDISTANCE FROM EXTREME END OF THE STERN OR STEM OF THE SHIP TO THE NEAREST SURVIVAL CRAFT IS MORE THAN 100 METERS IN ADDITION TO THE LIFE RAFTS REQUIRE IN 1.1 &1.2 OF THIS SECTION A LIFE RAFT STOWED AS FAR FORWARD AS PRACTICAL. PSCO OBSERVED THE FWD LIFERAFT WAS DAMAGED.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 25 January 2023
Resolved 25 January 2023
Resolution: Brand new liferaft delivered. Acknowledge by Class.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 24 January 2023Resolved
AFTER ANY SURVEY OF THE SHIP ANDER REGULATIONS 7,8,9 OR 10 HAS BEEN COMPLETED NO CHANGE SHALL BE MADE IN STRUCTURAL ARANGEMENTS, MACHINERY, EQUIPMENT AND OTHER ITEMS COVERED BY THE SURVEY, WITHOUT THE SANCTION OF THE ADMINISTRATION.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 February 2023
Resolved 13 February 2023
Resolution: Reviewed class report attesting to satisfactory repairs.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 24 January 2023Resolved
MUSTER AND EMBARKATION STATION SHALL BE ADEQUETLY ILLUMINATED FROM EMERGENCY SOURCE OF POWER REQUIRED BY II-1/4 2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 24 January 2023
Resolved 24 January 2023
Resolution: Corrected on the spot
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.