KARLA F

KARLA F is a 2008 offshore supply vessel. The Coast Guard has recorded 15 inspections since 2016, most recently in September 2025, along with 24 deficiencies and 3 operational controls.

Records from 2016 to 2025. Most recent: inspection, 18 September 2025.

Built
2008
Last inspected
18 September 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 2016.

Inspection record

Last inspected 18 September 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9555694
WDE3008
911294
Flag
UNITED STATES
Maury page id
psix-911294

Documentation record

Registered dimensions (L × B × D)153.3 ft × 36.0 ft × 12.0 ft
Registered tonnagegross 99 / net 68
ITC dimensions (L × B × D)153.3 ft × 36.0 ft × 12.0 ft
ITC tonnagegross 567 / net 197
BuilderMARINER LLC · HOUMA, LA, UNITED STATES · built 2008
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portHOUMA, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 3 December 2025 · expires 31 December 2026
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
567 - Convention (Subpart B), Gross Ton
660 - Dead Weight, Gross Ton
1175 - Displacement, Gross Ton
68 - Regulatory (Subpart C or D), Net Ton
197 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 15

18 September 2025 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8236028
25 March 2024 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7884894
11 March 2024 Cargo Tank Internal · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7876928
12 October 2023 Administrative Inspection · Examination of Repairs · Periodic Inspection · MTSA Verification · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7807074
8 July 2023 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7736544
7 July 2023 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7739691
28 September 2022 Deficiency Check
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7568562
19 September 2022 Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7560233
21 July 2021 Damage Survey
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7263156
20 July 2021 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7262373
10 June 2021 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7221910
10 May 2021 Hull Examination · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7193832
6 September 2017 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6261291
13 December 2016 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6057069
29 February 2016 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5823725

Deficiency record · 24

01 - Certificates & Documentation › 013 - Documents › Records of seafarers' daily hours of work or rest
Issued 18 September 2025 Resolved
Records of daily hours of rest must be maintained onboard and each affected crewmember must endorse it.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 18 September 2025
Resolved 18 September 2025
Resolution: Vessel Master will be logging work/rest hours in the bridge log.
01 - Certificates & Documentation › 013 - Documents › Shipboard working arrangements
Issued 18 September 2025 Resolved
Transfer procedures must specify the duties by title of each officer, PIC, deckhand and any other person required for each transfer operation. Master or Licensed Mate must act as PIC while procedures are amended and placed onboard. Transfer Procedures content must be IAW 33CFR155.750. Upon further review, noted that it's missing cargo info, line diagram, emptying discharge containment system, and oil-spill reporting procedures.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 October 2025
Resolved 13 November 2025
Resolution: The procedures now specify that the Master is responsible for overseeing all transfers (cargo and fuel).
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 18 September 2025 Resolved
Fire and abandonship drills must be performed on alternate weeks. These drills have not been performed consistently, and were missed multiple times.
Action required: 10 - Deficiency Rectified
Due 18 September 2025
Resolved 18 September 2025
Resolution: Fire drill was completed satisfactorily at day of CG inspection, Master made a reminder note in bridge log, and company safety manager released a fleetwide message.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 18 September 2025 Resolved
Paint locker must be constructed of steel and be protected with fixed firefighting equipment if dimensions exceed 60 cubic feet. Paint locker onboard is aluminum made and must be replaced or be wholly lined with steel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 October 2025
Resolved 13 November 2025
Resolution: Replaced with steel paint locker.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 25 March 2024 Resolved
Each OSV must carry the following equipment for the line-throwing appliance. For an appliance approved under 46 CFR 160.031 (shoulder gun type). One auxiliary line consisting of at least 500 ft. of 3in. circumference manila complying with federal specification T-R-605. Twenty-five cartridges of the caliber and loading specified in the instructions furnished by the manufacturer of the gun. Vessel did not have auxiliary line on board, and was missing one cartridge. - 46 CFR Part 133.170 / 46 CFR Part 160.031
Action required: 17 - Rectify deficiencies prior to departure
Due 25 March 2024
Resolved 4 April 2024
Resolution: Presence of required auxiliary line and all cartridges was verified.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 March 2024 Resolved
Except as provided by this part, the design, installation, testing, and inspection of machinery for OSVs of less than 6,000 GT ITC must comply with subchapter F. Fluid conditioner fittings (fuel filters) must meet ASTM 1201 standards. The vessel’s port and starboard generators have nonmetallic filters that do not meet ASTM 1201 fire test standards. - 46 CFR Part 128.110 / 46 CFR Part56.15-5
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 April 2024
Resolved 4 April 2024
Resolution: Port and starboard generator fuel filters were replaced with compliant metallic filters.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 25 March 2024 Resolved
Except as provided by this part, the design, installation, testing, and inspection of pressure vessels for OSVs of less than 6,000 GT ITC must comply with subchapter F. Where pressure-indicating gages are used, they shall be chosen to be compatible with the pressure to be indicated. In no case shall the upper range of the gage be less than 1.2 times nor more than 2 times the pressure at which the relieving device is set to function. Installed air receiver gauges are more than 2 times the pressure at which the relieving device is set to function. - 46 CFR Part 128.110 / 46 CFR Part 54.15-5
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 April 2024
Resolved 4 April 2024
Resolution: Both air receiver gauges were replaced. Newly installed gauges read up to 300PSI which is not more than 2 times the pressure at which the relieving devices are set to function (175PSI).
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 March 2024 Resolved
The frame or support of each semi-portable fire extinguisher must be secured to prevent the extinguisher from shifting in heavy weather. There was a semi-portable extinguisher on deck that didn’t have a means for securing. - 46 CFR Part 132.240
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 April 2024
Resolved 4 April 2024
Resolution: The semi-portable extinguisher on deck was properly secured.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 25 March 2024 Resolved
The owner of a vessel subject to inspection shall ensure that such vessel is equipped with a vessel master key control system, manual or electronic, which provides controlled access to all copies of the vessel's master key. Vessel does not have a master key control system and the Master has access to master keys. - 46 USC 3106(a)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 March 2024
Resolved 4 April 2024
Resolution: All doorknobs aboard the vessel were replaced with a non-lockable type (18 in total). The vessel no longer has a Master key to control.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 25 March 2024 Resolved
Fire and Abandon ship drills must be held on each vessel normally on alternate weeks. Vessel was not conducting drills on alternating weeks and was conducting drills monthly. -46 CFR 131.530(b) / 46 CFR 131.535
Action required: 10 - Deficiency Rectified
Due 25 March 2024
Resolved 25 March 2024
Resolution: Master was educated on the requirement to conduct drills on alternating weeks.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 12 October 2023 Resolved
Vessel must undergo an annual inspection within 3 months before or after each anniversary date. Vessel was found to be operating outside of annual window.
Condition: Invalid
Action required: 30 - Ship detained
Resolved 30 October 2023
Resolution: Completed to the satisfaction of attending MI.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 12 October 2023 Resolved
Mariners must meet medical and physical standards. Relief captain did not have valid medical certificate.
Action required: 30 - Ship detained
Resolved 30 October 2023
Resolution: Cleared to the satisfaction of attending MI.
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 12 October 2023 Resolved
Vessel must have a valid load line certificate. Watertight doors and hatches going into engine room and engine room escape hatch were not watertight. Bow thruster seal was not made watertight. ABS is not issuing load line certificate until these items are rectified.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 30 October 2023
Resolution: Load line certificate issued by ABS.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 12 October 2023 Resolved
Vessel must maintain a copy of VRP on board and be understood by the crew. There was no VRP on board.
Condition: Improper Installation
Action required: 30 - Ship detained
Resolved 30 October 2023
Resolution: Cleared to the satisfaction of attending MI.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 October 2023 Resolved
Vessel must have adequate emergency lighting fitted along line of escape. Emergency light in escape hatch was inoperable.
Action required: 30 - Ship detained
Resolved 30 October 2023
Resolution: Cleared to the satisfaction of attending MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 October 2023 Resolved
If vessel is to be altered or repaired, the plans and information must be submitted to the [name withheld] were three temporary repairs on the grey water discharge line. Repair proposal needs to be provided.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 30 October 2023
Resolution: Cleared to the satisfaction of attending MI.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 19 September 2022 Resolved
A vessel of less than 100 gross tons must have adequate emergency lighting fitted along the line of escape to the main deck from accommodations and working (machinery) spaces below the main deck. Engine room escape trunk light was extinguished and tunnel walkway was dim requiring a portable light to escape. Vessel to repair and test. 46 CFR 129.440(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 28 September 2022
Resolution: Emergency lighting repaired.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 19 September 2022 Resolved
Cargo tanks in which Grade B or C liquids that are to be transported shall be fitted with either individual pressure-vacuum relief valves which shall extend to a reasonable height above the weather deck. Cargo tank safety relief valves shall be inspected at least once in every 2 years. The safety relief valve discs must be lifted from their seats in the presence of a marine inspector by either liquid, gas, or vapor pressure at least once every 5 years to determine the accuracy of adjustment and, if necessary, must be reset. The relief valves for the methanol tanks did not have any records of being tested. 46 CFR 32.55-20(c), 46 CFR 38.25-10(a), 46 CFR 38.25-10(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 March 2024
Resolution: Vessel provided a 20OCT23 Methanol Pressure Vaccum Valve Test Report showing that the instalves P/V valves tested satisfactory
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 19 September 2022 Resolved
The following matters must be entered in each vessel's logbook: - Tests and inspection of Steering Gear, Whistle, and Means of Communication. Before departure. - Verification of Compliance with Applicable Stability Requirements. - Tests of Emergency Lighting and Power. Weekly, monthly, and twice-yearly. Complete tasks and log. 46 CFR 131.620(b),46 CFR 131.620(d), 46 CFR 131.620(g),
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 September 2022
Resolution: Required log entries provided to MI.
04 - Emergency Systems › N/A - No Subsystem › Damage control plan
Issued 19 September 2022 Resolved
At least one abandon-ship drill each 3 months must be held at night, unless the master determines it unsafe. Vessel was completing abandon ship drills, but none logged at night. 46 CFR 131.530(b)(9)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 September 2022
Resolution: Crew completed required drill.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 September 2022 Resolved
Each OSV must carry lifebuoys approved under approval series 160.150 or 160.050. Aft 01 deck lifebuoy grab line was frayed in several locations. Replace or renew grab line. 46 CFR 133.70(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 September 2022
Resolution: Life buoy was replaced.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 21 July 2021 Resolved
Vessel has stress fracture on port bow hull and inset about six inches long - 30"x18" impact area four feet above the water on cord seam. Vessel must comply with ABS rules for construction. Vessel to repair vessel hull to satisfaction of CG and ABS. Vessel not to depart AOR or engage in commercial ops until repair complete. Vessel authorized to transit to shipyard in Orange for repairs. 46 CFR 127.210
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 July 2021
Resolved 23 July 2021
Resolution: Repairs made to ABS standards with ABS attendance.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 10 May 2021 Resolved
The following worklist items were discovered by the inspection team and must be cleared prior to the vessel receiving credit for the drydock/ISE: 1.) #3 Starboard liquid mud tank had a wasted sounding tube in it. Renew as original. 2.) Port grey water tank discharge valve was wasted. Renew as original. 3.) Starboard grey water tank discharge valve was wasted. Renew as original.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 May 2021
Resolution: New check valves were installed and sounding tube was renewed as original.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 29 February 2016 Resolved
Permanently attach the switchboard to the deck.
Action required: 705 - Other - as specified
Due 29 February 2016
Resolved 2 March 2016
Resolution: Vessel's crew/shipyard made permanent arrangements for the switchboard