MAURY USCG vessel records Sign in
← All vessels

HORIZON

HORIZON is a 2007 freight ship. The Coast Guard has recorded 22 inspections since 2008, most recently in January 2024, along with 10 deficiencies and 7 operational controls.

Records from 2008 to 2024. Most recent: inspection, 20 January 2024.

Built
2007
Last inspected
20 January 2024
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9323637 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
911518
Flag
LIBERIA
—
Maury page id
psix-911518

Inspections, by type

…with no type recorded7
Years with a record 11 calendar years (2008–2024)
The 22 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it19891 - Convention (Subpart B), Gross Ton
10297 - Convention (Subpart B), Net Ton
30803 - Dead Weight, Metric Ton
38768 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 22

20 January 2024 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7852132
1 October 2023 COE-Dockside
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7801717
30 January 2023 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7629378
22 November 2022 PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7596186
4 December 2020 ISPS Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7106195
1 December 2020 COE-Offshore
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7104669
1 December 2020 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7104678
11 March 2020 Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6924763
18 February 2020 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6908455
10 May 2018 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6400936
13 March 2017 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6103238
12 March 2017 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6103149
19 April 2016 In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5857349
1 April 2016 ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5845006
2 November 2015 COE-Offshore
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5755437
30 October 2015 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5754135
4 July 2011 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4068837
3 July 2011 COE-Dockside
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4061691
7 May 2009 MARPOL Annex I Examination · MARPOL Annex V Examination · ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3469322
4 May 2009 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3467426
24 April 2008 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3190933
24 April 2008 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3191092

Deficiency record · 10

07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 22 November 2022 Resolved
07105 - Fire doors/openings in fire-resisting divisions The fire resistance of doors shall be equivalent to that of the division in which they are fitted. PSCO observed both main galley doors were marked as class "C" division doors when main galley bulkhead is required to be class "A" division per SOLAS. 74 SOLAS (09) II-2/9.4.2.1
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 December 2022
Resolved 20 January 2024
Resolution: PSC NOLA received a class report from issuing entity satisfying the requirement.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 1 December 2020 Resolved
Deck log improperly documented. Security protocals was not documented.
Condition: Improper/Lack of Maintenance
Action required: 25 - Ship denied entry
Due 2 December 2020
Resolved 20 January 2024
Resolution: PSC NOLA received a class report from issuing entity satisfying the requirement.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 18 February 2020 Resolved
The purpose of this regulation is prevent ignition of combustible materials or flammable liquids. For this purpose, the following functional requirements shall be met. Means shall be provided to control leaks of flammable liquids. PSCO observed leaks of flammable liquids. #2 Aux engines no 3, 4, and 5 cylinders were leaking and the no. 1 aux engine's fuel pump was leaking. Solas 74(a)2014(cons.)II-2/4.1.1 17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 February 2020
Resolution: Received class report
10 - Safety of Navigation › N/A - No Subsystem › Voyage data recorder (VDR)/Simplified Voyage data recorder(S-VDR)
Issued 18 February 2020 Resolved
To assist in casualty investigations, cargo ships when engaged on international voyages, shall be fitted with a VDR. PSCO observed 01 of the VDR microphones connected to the VDR was inoperable and causing an alarm on the bridge. Vessel had flag dispensation, but made no report to port authority as required on dispensation. Solas74(a)2014(cons.)II-2/4.1.1 17AC
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 February 2020
Resolution: Accepted technician report
12 - Dangerous Goods › N/A - No Subsystem › Fire protection cargo deck area
Issued 18 February 2020 Resolved
Cargo spaces on cargo ships of 2,000 gross tonnage and upwards shall be protected by a fixed carbon dioxide or inert gas fire-extinguishing system complying with the Fire Safety Systems Code. PSCO observed delivery lines for CO2 to cargo holds No. 2 & 3 were completely broken; therefore one CO2 system and smoke extraction systems were inoperable for those holds. Vessel was unable to provide exemption certificate IAW SOLAS 2014 #12/10.7.1.4. Solas74(a)2014(cons.)II-2/10.7.1.3 Cargo restricted
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 February 2020
Resolution: Received Class report
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 18 February 2020 Resolved
Where "A" Class divisions are penetrated, such penetrations shall be tested in accordance with the Fire Test Procedures Code. Such penetrations shall be suitably insulated by extension of the insulation at the same level of one division. PSCO observed large crack in the putty on in the CO2 room; therefore not maintaining the A-60 integrity. Solas74(a)2014(cons.)II-2/9.3.1 16A
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 February 2020
Resolution: Received Class report
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 18 February 2020 Resolved
The ring, lines, and letters shall be painted in white or yellow on a dark ground background. They shall also be permanently marked on the sides of the ship to the satisfaction of admin. PSCO observed both port and starboard load line markings were deteriorated and wasted. ICLL ANNEX I 88 Protocol Reg. 8 40C
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 23 February 2020
Resolution: Received Class report
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 February 2020 Resolved
In addition to the requirements contained elsewhere in the present regulations, ships shall be designed, constructed and maintained in compliance with the structural, mechanical, and electrical requirements of a classification society. PSCO observed unapproved drainage pipe for engine control room AC unit to cascade tank. 10C Solas74(a)2004(cons.)II-1/3-1
Action required: 10 - Deficiency Rectified
Resolved 18 February 2020
Resolution: Chief officer removed unapproved pipe.
Construction/Loadline › Penetrations › Weld
Issued 10 May 2018 Resolved
External door outside hospital space is heavily corroded and not weathertight.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 May 2018
Resolution: PSC NOLA RECIEVED NON CONFORMITY REPORT SHOWING CORRECTIVE ACTION COMPLETE.
Deck/Cargo › Mooring/Anchoring › Winch
Issued 24 April 2008 Resolved
Vessel reported that its starboard anchor will not come up.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 April 2008
Resolved 24 April 2008
Resolution: Received Class report attesting to repairs of starboard anchor windlass

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.