Inspection history · 73
22 September 2025
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8203980
6 March 2025
Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8067008
25 June 2024
Deficiency Check · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7908964
31 October 2023
Drydock Exam · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7813834
15 September 2023
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7790068
31 August 2023
Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7762698
21 August 2023
Administrative Inspection · Drydock Extension
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7773709
25 May 2023
Internal Structural Exam · Drydock Extension
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7685493
17 October 2022
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7579112
23 August 2022
Periodic Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7491703
31 August 2021
Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7301111
30 July 2020
Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7020012
24 June 2020
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6985688
2 May 2019
COI Inspection · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6675330
28 June 2018
Drydock Exam · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6417017
18 June 2018
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6384535
27 March 2017
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6105309
16 March 2016
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5830710
6 July 2015
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5176109
10 April 2015
Drydock Exam · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5081764
10 April 2014
COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4820717
3 April 2012
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4257083
14 July 2010
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3794745
14 June 2010
Drydock Exam · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3763910
13 April 2009
COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3450275
13 November 2008
Hull Examination · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3350735
15 August 2007
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3016430
16 August 2006
COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2740091
18 April 2006
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2624880
2 March 2006
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2594905
24 October 2005
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2518718
29 June 2005
Internal Structural Exam · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2411190
3 June 2005
Internal Structural Exam · Drydock Extension
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2378194
21 October 2004
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2223870
26 March 2004
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2021595
29 May 2003
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1799003
5 May 2003
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1787268
16 September 2002
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1675326
16 August 2001
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1382385
3 October 2000
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1433757
1 June 2000
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1405025
18 August 1999
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1468529
15 September 1998
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1392983
21 May 1998
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1440008
22 August 1997
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1368358
5 September 1996
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1254488
26 August 1996
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1357706
26 January 1996
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 652378
1 November 1995
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 880430
30 August 1995
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 213689
30 August 1995
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 214285
30 August 1995
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1374370
9 June 1995
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 877021
29 August 1994
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 867646
16 August 1994
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1358500
12 January 1994
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1160648
7 December 1993
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1387430
17 November 1993
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1435417
20 September 1993
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 840220
2 October 1992
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1393871
8 July 1992
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 962684
8 July 1992
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1263231
21 October 1991
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1257048
20 September 1991
Deficiency Check · COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1311160
24 August 1990
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1215052
9 July 1990
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 900416
22 September 1989
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 895251
19 June 1989
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 890863
10 February 1989
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1034014
27 January 1986
Damage Survey
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 999792
25 June 1985
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1298107
14 June 1985
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1288990
10 April 1985
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 981769
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 25 June 2024
Resolved
The general construction of the vessel shall be such as to minimize fire hazards insofar as is reasonable and practicable. Generator prime mover exhaust system missing thermal protective lagging.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2024
Resolved 15 July 2024
Resolution: Lagging installed.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 31 August 2023
Resolved
The person in command of a documented vessel must have on board that vessel the original Certificate of Documentation currently in effect for that vessel. The Certificate of Documentation carried on board was found to be expired.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 September 2023
Resolved 5 September 2023
Resolution: Recieved picture proof of valid COD.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 May 2023
Resolved
No repairs or alterations affecting the safety of the vessel with regard to the hull, machinery, or equipment shall be made without the knowledge of the Officer in Charge, Marine Inspection. Marine Inspector noticed rust/corrosion/hole on fwd crane stand at fwd port and starboard upper enclosure corners. Repair at next drydock. 46 CFR 91.45-1 (a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 October 2023
Resolution: Repairs completed and observed by attending MI's
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 31 August 2021
Resolved
Each machinery space must be ventilated to ensure that when machinery is operating at full power in all weather including heavy weather an adequate supply of air is maintained for the operation of the machinery and for the safety. The oil vent line of the machinery space generator (Below round house) was found to be venting into the space. The space lacks ventilation to ensure a safe environment.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 September 2021
Resolved 31 March 2022
Resolution: Two electric ventilation fans have been added to the space and vent to atmosphere.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 31 August 2021
Resolved
The requirements of 46CFR58.10-5(a) shall apply; all installations shall be suitable for the intended service. Oil was found to be leaking from the generator located within the below deck machinery space.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2021
Resolved 31 March 2022
Resolution: Generator was serviced by a mechanic, oil leak is resolved.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 31 August 2021
Resolved
At each inspection for certification and periodic inspection the inspector shall examine the vessel to determine that it meets the vessel design and equipment requirements for pollution prevention. Inspector found the anchor winch to be leaking gear oil due to prior damage of the machinery.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2021
Resolved 31 March 2022
Resolution: The anchor winch has been repaired and the oil leak secured.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 31 August 2021
Resolved
Electric installations on vessels must ensure protection of crew from electrical hazards. Throughout the vessel inspector identified dead end cables. As an example, on the exterior of the round house an exposed electrical wire was found within a junction box that is missing the cover.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2021
Resolved 31 March 2022
Resolution: Junction box cover has been installed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 31 August 2021
Resolved
Electric installations on vessels must ensure protection of crew from electrical hazards. Within the anchor winch cab inspector found two power strips connected and drawing power from a single outlet (i.e. daisy chain).
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2021
Resolved 31 March 2022
Resolution: Additionally hard wire outlets have been installed in the anchor winch cab; power strips have been removed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 31 August 2021
Resolved
Electric installations on vessels must ensure protection of crew from electrical hazards. Inspector found that the electrical panel intended to prevent unintentional contact was missing from within the crane cab console.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2021
Resolved 31 March 2022
Resolution: The electrical panel/cover has been reinstalled.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 31 August 2021
Resolved
Electric equipment must be arranged, as far as practicable, to prevent mechanical damage to the equipment from dripping liquids. Inspector found that the battery utilized to power the on-deck wash basin has exposed terminal that are subject to water exposure; the exposed terminals also present a contact hazard.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2021
Resolved 31 March 2022
Resolution: A cover has been applied to the exposed terminal.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 31 August 2021
Resolved
The inspection for certification shall include an inspection of the structure. Inspector found that the exterior deck (i.e. cat walk) around the crane is wasted through in several areas and at the base of the access ladder.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2021
Resolved 31 March 2022
Resolution: Wasted areas of cat walk have been replaced with good steel.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 31 August 2021
Resolved
Every vessel, dredge, or floating plant must have a radiotelephone onboard capable of operation from its main control station. The FCC Radio Station Authorization was found to have expired on July 24, 2020.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2021
Resolved 31 March 2022
Resolution: FCC Radio Station Authorization has been renewed.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 30 July 2020
Resolved
Each fixture globe, lens or diffuser must have a high strength guard or be made of high strength material. Two lighting fixtures within the crane machinery space were found to be improper: one was missing the high strength globe and another had sustained damaged (crack) to the high strength globe.
46 CFR 111.75-20
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 August 2020
Resolved 13 August 2020
Resolution: High strength globes applied to both lighting fixtures.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 July 2020
Resolved
Each moderate battery installation must be in a box or locker in another space such as an engine room or similar space. Two batteries connected to the lower generator and installed below the generator were found to be saturated with oil (i.e. oil dripping from generator). Additionally, an absorbent pad was laying across the terminals to absorb the dripping oil. A box lid is necessary to protect the battery terminals.
46 CFR 111.15-5
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 August 2020
Resolved 13 August 2020
Resolution: Lids were placed onto the battery boxes to prevent further exposure to dripping oil.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 July 2020
Resolved
Life buoys were found to be co-located on the stern of the barge; one life buoy must be placed on each end of the barge. Additionally, the grab lines were found to be weathered and require replacement.
46 CFR 199.70
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 August 2020
Resolved 13 August 2020
Resolution: A life buoy was installed on each end of the barge and grab lines replaced.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 2 May 2019
Resolved
Vessel is overdue for COI inspection and must complete a satisfactory COI inspection prior to operating outside the boundary line.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 June 2019
Resolution: COI inspection completed.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 6 July 2015
Resolved
Missing Sound producing devices
Action required: 705 - Other - as specified
Due 6 August 2015
Resolved 26 August 2015
Documentation › Certificates/Documents › International Load Line Certificate
Issued 6 July 2015
Resolved
Not on board
Action required: 705 - Other - as specified
Due 10 July 2015
Resolved 7 July 2015
Resolution: Loadline cert was emailed.
Construction/Loadline › Structures › Deck Plating
Issued 10 April 2015
Resolved
Repair 2" fracture on main deck IWO #9 STBD aft. (Worklist item)
Action required: 705 - Other - as specified
Resolved 24 June 2015
Resolution: fracture repaired.
Construction/Loadline › Hull › Keel Plate
Issued 10 April 2015
Resolved
Repair inset between 1 and 2 chord bilge knuckle in the # 7 void. (Worklist Item).
Action required: 705 - Other - as specified
Resolved 17 June 2015
Resolution: repaired.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 10 April 2015
Resolved
Repair aft bulkhead IWO hatch opening at the main deck. (Worklist Item)
Action required: 705 - Other - as specified
Resolved 24 June 2015
Resolution: repaired.
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 10 April 2015
Resolved
Reweld fuel tank center on port bulkhead 1" from the aft bulkhead (worklist item)
Action required: 705 - Other - as specified
Resolved 19 June 2015
Resolution: repaired and test sat.
Construction/Loadline › Structures › Scuttle
Issued 10 April 2015
Resolved
Repair various hatch combings
Action required: 705 - Other - as specified
Resolved 24 June 2015
Resolution: Hatches for voids #1, 2, 5, 6, 8, 9 replaced.
Electrical › Electric Supply System (service) › Battery Installation
Issued 10 April 2014
Resolved
Clean or replace battery terminals for both generator sets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 April 2014
Resolved 15 May 2014
Resolution: Batteries replaced.
Accommodation/Occupational Safety › Occupational Safety › Welding/Hot Work
Issued 10 April 2014
Resolved
Provide proper storage off the deck for oxygen and acetylene bottles.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 April 2014
Resolved 15 May 2014
Resolution: Provided off the deck storage.
Engineering › Compressed Air System (control) › Hose
Issued 10 April 2014
Resolved
Repair of replace support for air controls on breasting winch.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 April 2014
Resolved 15 May 2014
Resolution: Repaired support.
Documentation › Certificates/Documents › Certificate of Financial Responsibility
Issued 3 April 2012
Resolved
Renew vessel certificate of financial responsibility.
Due 10 April 2012
Resolved 11 April 2012
Resolution: Received confirmation of a valid COFR for the vessel.
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 13 April 2009
Resolved
Demonstrate proper operation of the generator low L/O, high J/W and overspeed alarms/shutdowns.
Condition: Unknown
Action required: 705 - Other - as specified
Due 13 May 2009
Resolved 24 April 2009
Resolution: Proper operation demonstrated.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Overspeed Device
Issued 24 October 2005
Resolved
Demonstrate proper operation of the barge generator overspeed shutdown.
Action required: 705 - Other - as specified
Due 2 April 2006
Resolved 18 April 2006
Deck/Cargo › Cargo Transfer (solid) › General
Issued 24 October 2005
Resolved
Provide a crane certificate as per 46 CFR 91.25-25. The crane may not be used for cargo or work until a current crane certificate is obtained.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 April 2006
Resolved 18 April 2006
Resolution: Crane cert 051012A101 issued 12Oct2005 exp 15Oct2006.
Documentation › Certificates/Documents › International Load Line Certificate
Issued 24 October 2005
Resolved
Provide a current Loadline certificate. The vessel may not procede seaward of the boundary line until the Loadline is renewed.
Action required: 705 - Other - as specified
Due 24 November 2005
Resolved 2 March 2006
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 24 October 2005
Resolved
Provide lanyards and clips for the ring buoy waterlights.
Action required: 705 - Other - as specified
Due 2 April 2006
Resolved 24 October 2005
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 26 March 2004
Resolved
Noticed both ring life buoys were barely legible due to heavy oil coating. Both port and starboard ring buoys were no longer orange in color due to excessive fading and or oil coating. Required operator to replace both rings. LEGACY COMPONENT DESC: Markings (ship name/port)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 April 2004
Resolved 28 October 2004
Resolution: Replaced ring bouys, both were orange and markings legible.
Documentation › Certificates/Documents
Issued 26 March 2004
Resolved
Produce current IOPP. LEGACY COMPONENT DESC: IOPP Certificate
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 April 2004
Resolved 29 March 2004
Resolution: New IOPP issued to correspond with existing COI dates
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 26 March 2004
Resolved
Required operator to provide waste management plan per 33 CFR 151.57 LEGACY COMPONENT DESC: Waste Management Plan
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 April 2004
Resolved 28 October 2004
Resolution: Provided waste management plan.
Documentation › Certificates/Documents
Issued 26 March 2004
Resolved
Provide current cargo gear certificate for derrick crane in accordance with 46 CFR 31.10-16 and 46CFR 97.12-1
Action required: 705 - Other - as specified
Due 26 April 2004
Resolved 27 April 2004
Resolution: Operator faxed over copy of most current cargo gear certificate.
Engineering › Generator (propulsion-electric) › Winding
Issued 26 March 2004
Resolved
Required operator to provide lagging on upper deck generator exhaust system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 April 2004
Resolved 28 October 2004
Resolution: Provided lagging.
Documentation › Certificates/Documents
Issued 16 September 2002
Resolved
Provide proof of Certificat of Documentation. Barge only had copy on board and could not produce original. LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Due 23 September 2002
Resolved 23 September 2002
Documentation › Certificates/Documents
Issued 16 September 2002
Resolved
Provide proof of IOPP Form A. Barge did not have complete IOPP Form A. Missing endorsement page, could not endorse IOPP. LEGACY COMPONENT DESC: IOPP Certificate
Due 23 September 2002
Resolved 23 September 2002
Documentation › Certificates/Documents
Issued 16 September 2002
Resolved
Provide proof of SOPEP annual review. LEGACY COMPONENT DESC: SOPEP
Due 23 September 2002
Resolved 23 September 2002
Electrical › Electric Generation Source (service)
Issued 16 September 2002
Resolved
Provide proof of operation of overspeed trips, low lube oil shutdowns and high water temp alarms for both generators. LEGACY COMPONENT DESC: Generator
Due 23 September 2002
Resolved 23 September 2002
Electrical › Lighting (service)
Issued 16 September 2002
Resolved
Install lens covers on exterior lighting fixtures. LEGACY COMPONENT DESC: Lighting Fixture
Due 23 September 2002
Resolved 23 September 2002
Navigation › Collision/Grounding Avoidance
Issued 16 September 2002
Resolved
Repair red navigation light on the top of the mast. LEGACY COMPONENT DESC: Navigation Lights
Due 23 September 2002
Resolved 23 September 2002
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 16 September 2002
Resolved
replace fire extinguisher bracket with corredt bracket in lower generator room. Bracket was the wrong type and did not hold extinguisher in place. LEGACY COMPONENT DESC: Mounting Bracket
Due 23 September 2002
Resolved 23 September 2002
Pollution Prevention/Response › Prevention Equipment
Issued 16 September 2002
Resolved
Plug and repair wasted fuel containment on forward fuel oil tank, along the starboard side of the barge. LEGACY COMPONENT DESC: Fixed Containment
Due 23 September 2002
Resolved 23 September 2002
Electrical › Electric Supply System (service)
Issued 16 September 2002
Resolved
Install circuit protection on installed battery chargers and batteries in the radio room and upper generator room. LEGACY COMPONENT DESC: Battery Charger
Due 23 September 2002
Resolved 23 September 2002
Lifesaving › Lifebuoys
Issued 16 September 2002
Resolved
Replace line on both ring life buoys. LEGACY COMPONENT DESC: Buoyant Lifeline
Condition: Improper/Lack of Maintenance
Due 23 September 2002
Resolved 23 September 2002
Engineering › Fuel Oil Storage/Transfer System
Issued 16 September 2002
Resolved
Provide proof of 30x30 mesh screen on vents on upper fuel tank, on the crane body. LEGACY COMPONENT DESC: Vent Pipe
Due 23 September 2002
Resolved 23 September 2002
Accommodation/Occupational Safety
Issued 16 August 2001
Resolved
Ensure pressure relief valve on lower pressure vessel relieves below MAWP.
Condition: Unknown
Due 21 September 2001
Resolved 21 September 2001
Lifesaving
Issued 3 October 2000
Resolved
CONDUCT GAUGING ON AIR RECEIVERS.
Condition: Unknown
Due 30 November 2000
Resolved 18 December 2000
Lifesaving
Issued 15 September 1998
Resolved
PROVIDE GAUGING REPORT FOR BOTH AIR RECEIVERS (PRESSURE VESSELS) PRIOR TO 03 OCT 98.
Condition: Unknown
Due 2 October 1998
Resolved 2 October 1998
Lifesaving
Issued 26 August 1996
Resolved
_x001C_ BUOYANT APPARATUS NEEDS SERVICING. DUE 6/96
Condition: Unknown
Due 9 September 1996
Resolved 5 September 1996
Electrical
Issued 26 August 1996
Resolved
PROVE PROPER OPERATION OF LOW LUBE OIL SHUTDOWN ON UPPER AND LOWER GENERATORS. ALSO, PROVE PROPER OPERATION OF OVERSPEED TRIP ON LOWER GENERATOR.
Condition: Unknown
Due 9 September 1996
Resolved 5 September 1996
Electrical
Issued 30 August 1995
Resolved
Provide cover for electrical junction box on back of crane pedestal.
Condition: Unknown
Due 25 September 1995
Resolved 27 September 1995
Deck/Cargo
Issued 30 August 1995
Resolved
Prove operation of relief valve on deck winch air receiver.
Condition: Unknown
Due 25 September 1995
Resolved 27 September 1995
Documentation
Issued 30 August 1995
Resolved
Provide an approved Shipboard Oil Pollution Emergency Plan(SOPEP). Vessel cannot cross boundary line or transfer fuel until this item is completed.
Condition: Unknown
Due 30 August 1995
Resolved 30 August 1995
Lifesaving
Issued 30 August 1995
Resolved
Store flammable liquids in existing metal locker on deck.
Condition: Unknown
Due 25 September 1995
Resolved 27 September 1995
Deck/Cargo
Issued 30 August 1995
Resolved
Provide relief valve for barge engine room air receiver which will relieve before MAWP of tank.
Condition: Unknown
Due 25 September 1995
Resolved 27 September 1995
Documentation
Issued 30 August 1995
Resolved
Provide oil transfer procedures as per 33 CFR 155.750. Vessel cannot transfer oil until this deficiency is corrected.
Condition: Unknown
Due 30 August 1995
Resolved 30 August 1995
Engineering
Issued 30 August 1995
Resolved
Repair fuel leak on A-C generator set in barge engine room.
Condition: Unknown
Due 25 September 1995
Resolved 27 September 1995
Engineering
Issued 30 August 1995
Resolved
Provide flame screen for deck winch fuel tank vent.
Condition: Unknown
Due 25 September 1995
Resolved 27 September 1995
Fire Fighting
Issued 30 August 1995
Resolved
Provide mount for fire extinguisher in crane engine house.
Condition: Unknown
Due 25 September 1995
Resolved 27 September 1995
Engineering
Issued 30 August 1995
Resolved
Label fuel pump shut off switch(circuit breaker) in deckhouse.
Condition: Unknown
Due 25 September 1995
Resolved 27 September 1995
Engineering
Issued 16 August 1994
Resolved
CHANGE RELIEF VALVE ON AIR RECEIVER IN GENERATOR ROOM TO A PRESSURE SETTINGNOT TO EXCEED THE MAXIMUM ALLOWABLE WORKING PRESSURE OF THE AIR RECEIVER.
Condition: Unknown
Due 16 August 1994
Resolved 16 August 1994
Engineering
Issued 16 August 1994
Resolved
PROVE PROPER OPERATION OF ALL THREE RELIEF VALVES ON AIR RECEIVERS.
Condition: Unknown
Due 16 August 1994
Resolved 16 August 1994
Accommodation/Occupational Safety
Issued 7 December 1993
Resolved
REMOVE OIL FROM DECK UNDER HOSE REEL STATION, PRIOR TO A POLLUTION INCIDENTOCCURING DUE TO WEATHER.
Condition: Unknown
Due 7 December 1993
Resolved 7 December 1993
Accommodation/Occupational Safety
Issued 7 December 1993
Resolved
PROVIDE DATA PLATE FOR ON DECK AIR RECEIVER RELIEF VALVE.
Condition: Unknown
Due 7 December 1993
Resolved 7 December 1993
Electrical
Issued 7 December 1993
Resolved
PROPERLY SECURE AND PROTECT BATTERIES IN CRANE HOUSE FROM MOVEMENT.
Condition: Unknown
Due 7 December 1993
Resolved 7 December 1993
Lifesaving
Issued 17 November 1993
Resolved
PRIOR TO INDUSTRIAL CREW COMING ABOARD, THE REQUIRED LIFESAVING EQUIPMENT AS LISTED ON THE CERTIFICATE OF INSPECTION MUST BE ABOARD AND INSPECTED TO THE SATISFACTION OF AN ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 17 November 1993
Resolved 17 November 1993
Deck/Cargo
Issued 20 September 1993
Resolved
PRIOR TO USING CRANE, CRANE MUST PASS A SAFE WORKING LOAD TEST AND BE PROPERLY MARKED TO THE SATISFACTION OF AN ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 20 September 1993
Resolved 20 September 1993
Documentation
Issued 20 September 1993
Resolved
PRIOR TO TRANSFERING ANY OIL ABOARD OR TO THE BARGE, PROVIDE A COPY OF OIL TRANSFER PROCEDURES AS REQUIRED BY 33 CODE OF FEDERAL REGULATIONS PART 155.720 AND 155.750.
Condition: Unknown
Due 20 September 1993
Resolved 20 September 1993
Electrical
Issued 20 September 1993
Resolved
PROPERLY REPAIR LIGHT FIXTURES IN CRANE ENGINE HOUSE.
Condition: Unknown
Due 20 September 1993
Resolved 20 September 1993
Lifesaving
Issued 20 September 1993
Resolved
REMOVE PAINT CANS FROM PORTSIDE DECK.
Condition: Unknown
Due 20 September 1993
Resolved 20 September 1993
Lifesaving
Issued 20 September 1993
Resolved
PROPERLY REMOVE OIL STAIN FROM DECK.
Condition: Unknown
Due 20 September 1993
Resolved 20 September 1993
Electrical
Issued 20 September 1993
Resolved
DEMONSTRATE PROPER OPERATION OF ELECTRICAL GENERATOR.
Condition: Unknown
Due 20 September 1993
Resolved 20 September 1993
Accommodation/Occupational Safety
Issued 20 September 1993
Resolved
DEMONSTRATE PROPER OPERATION OF ALL AIR RECEIVERS RELIEF VALVES.
Condition: Unknown
Due 20 September 1993
Resolved 20 September 1993
Documentation
Issued 20 September 1993
Resolved
PRIOR TO VESSEL BEING MOVED OR TRANSFERING ANY OIL ABOARD THE VESSEL, PROVIDE A VALID CERTIFICATE OF FINANCIAL RESPONSIBILITY.
Condition: Unknown
Due 18 October 1993
Resolved 18 October 1993
Engineering
Issued 20 September 1993
Resolved
PRIOR TO USING DIESEL OIL OR LUBE OIL HOSES ABOARD THE BARGE, HAVE HOSES TESTED AND MARKED IN ACCORDANCE WITH 33 CODE OF FEDERAL REGULATION PART 155.800 AND 154.500.
Condition: Unknown
Due 20 September 1993
Resolved 20 September 1993
Electrical
Issued 20 September 1993
Resolved
PRIOR TO USING BARGE AS AN INDUSTRIAL VESSEL, A COAST GUARD MARINE INSPECTOR WILL BE REQUIRED TO INSPECT FOR THE REMOVAL OF ALL ELECTRICAL JURY RIG WIRING DUE TO VESSEL'S LAY UP.
Condition: Unknown
Due 20 September 1993
Resolved 20 September 1993
Lifesaving
Issued 20 September 1993
Resolved
PRIOR TO INDUSTRIAL CREW COMING ABOARD, THE REQUIRED LIFESAVING EQUIPMENT AS LISTED ON THE CERTIFICATE OF INSPECTION MUST BE ABOARD AND INSPECTED TO THE SATISFACTION OF AN ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 20 September 1993
Resolved 20 September 1993
Electrical
Issued 20 September 1993
Resolved
PROPERLY HANG OVERHEAD WIRING IN CRANE ENGINE HOUSE.
Condition: Unknown
Due 20 September 1993
Resolved 20 September 1993
Fire Fighting
Issued 8 July 1992
Resolved
PRIOR TO OPERATION OF ANY MACHINERY OR TRANSFERRING OF FUEL OIL, HAVE ALL FIRE EXTINGUISHERS SERVICED.
Condition: Unknown
Due 8 July 1992
Resolved 8 July 1992
Construction/Loadline
Issued 8 July 1992
Resolved
PROPERLY MARK LOAD LINE ON VESSEL'S HULL.
Condition: Unknown
Due 8 July 1992
Resolved 8 July 1992
Construction/Loadline
Issued 8 July 1992
Resolved
PROPERLY MARK DRAFT MARKS ON VESSEL'S HULL.
Condition: Unknown
Due 8 July 1992
Resolved 8 July 1992
Navigation
Issued 8 July 1992
Resolved
PRIOR TO GETTING UNDERWAY IN REDUCED VISIBILITY SHOW PROPER OPERATION OF NAVIGATIONAL LIGHTS.
Condition: Unknown
Due 8 July 1992
Resolved 8 July 1992
Construction/Loadline
Issued 8 July 1992
Resolved
PROPERLY MARK VESSEL'S NAME ON HULL.
Condition: Unknown
Due 8 July 1992
Resolved 8 July 1992
Engineering
Issued 20 September 1991
Resolved
POST AN OIL POLLUTION PLACARD.
Condition: Unknown
Due 20 September 1991
Resolved 20 September 1991
Lifesaving
Issued 20 September 1991
Resolved
PRIOR TO INDUSTRIAL CREW BEING ALLOWED ON BOARD, HAVE A COAST GUARD INSPECTOR INSPECT THE REQUIRED LIFESAVING GEAR.
Condition: Unknown
Due 20 September 1991
Resolved 20 September 1991
Accommodation/Occupational Safety
Issued 20 September 1991
Resolved
DEMONSTRATE PROPER OPERATION OF SAFETY RELIEF VALVE ON AIR RECEIVER.
Condition: Unknown
Due 24 September 1991
Resolved 24 September 1991
Engineering
Issued 20 September 1991
Resolved
PROVIDE A COPY OF VESSEL'S OIL TRANSFER PROCEDURES AS REQUIRED BY 33 CFR 155.750.
Condition: Unknown
Due 20 September 1991
Resolved 20 September 1991
Documentation
Issued 25 June 1985
Resolved
PLACE ON BOARD VESSEL'S FCC LICENSE.
Condition: Unknown
Due 25 June 1985
Resolved 25 June 1985
Documentation
Issued 25 June 1985
Resolved
SUBMIT PLANS DETAILING THE STRUCTURE OF THE INTEGRAL FUEL TANK FOR REVIEW.
Condition: Unknown
Due 25 June 1985
Resolved 25 June 1985
Unknown
Issued 25 June 1985
Resolved
OBTAIN ABS LOADLINE DOCUMENT AND PLACE ON BOARD THE VESSEL.
Condition: Unknown
Due 25 June 1985
Resolved 25 June 1985
Deck/Cargo
Issued 25 June 1985
Resolved
MAKE AVAILABLE FOR TESTING OR PROVIDE TEST DOCUMENTS FOR VESSEL CRANE.
Condition: Unknown
Due 25 June 1985
Resolved 25 June 1985