4 June 2026
Annual Inspection · Drydock Exam
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8390688
10 June 2025
Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8156128
6 June 2024
Annual Inspection · Drydock Exam
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 7929752
6 June 2023
Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7710227
8 June 2022
Deficiency Check · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7472078
17 June 2021
Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7226515
13 August 2020
Drydock Exam · Internal Structural Exam · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7032038
16 January 2020
Examination of Repairs · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6891195
27 November 2019
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6873096
10 September 2019
DAPI Audit · Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6808828
6 August 2018
Deficiency Check · Annual Inspection · DAPI Audit · Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6502950
2 September 2017
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6271186
2 June 2017
DAPI Audit · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6163752
31 August 2016
Annual Inspection · Internal Structural Exam · DAPI Audit · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6025839
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 10 June 2025
Resolved
At each inspection of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of the hull structure and its appurtenances, including the following: Inspection and operation of through hull fittings. Aft bilge overboard discharge through hull fitting at transom, loose and unsecured. Requires repair or renewal. 46 CFR 176.802(a)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 July 2025
Resolved 8 July 2025
Resolution: Aft bilge overboard discharge through hull fitting replaced.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 6 June 2023
Resolved
All vessels must have operable navigation lights in accordance with the Navigation Rules. All-around light not showing an unbroken light over an arc of the horizon of 360 degrees. Light is mounted in area where it is obstructed. Provide all-around light showing an unbroken light over an arc of the horizon of 360 degrees.
46 CFR 183.420
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2023
Resolved 14 June 2023
Resolution: Light mounted in unobstructed area.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 June 2023
Resolved
Portable extinguisher must be located so that they are clearly visible. Extinguisher stowed in cabinet and no marking provided. Provide marking on exterior of storage area to show that extinguisher is inside.
46 CFR 181.520
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2023
Resolved 14 June 2023
Resolution: Extinguisher cabinet marked.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 June 2023
Resolved
Remote fuel shut off stations must be marked in clearly legible 1 inch letter indicating purpose of the valve and the direction of operation. Fuel shut off marking missing on exterior of space. Provide fuel shut off marking.
46 CFR 185.608
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2023
Resolved 14 June 2023
Resolution: Fuel shut off marking provided.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 8 June 2022
Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: The date of the drill and training; and general description of the drill scenario and training topics. Drills were not logged properly.
46 CFR 185.520(f)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 July 2022
Resolved 5 July 2022
Resolution: Drills logged properly.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 8 June 2022
Resolved
The master of the vessel shall ensure that: The EPIRB test required by paragraph (a) shall be logged. The EPIRB test are not logged in vessel's logbook.
46 CFR 185.728
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 July 2022
Resolved 5 July 2022
Resolution: EPIRB testing logged.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 8 June 2022
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: Charts of large enough scale to make safe navigation possible. Charts on board were not up-to-date.
46 CFR 184.420(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 July 2022
Resolved 20 June 2022
Resolution: Chart provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 June 2022
Resolved
A submersible electric bilge pump may be used as a power bilge pump only on a vessel of not more than 65 feet in length carrying not more than 49 passengers, other than a ferry, provided that the pump is listed by an independent laboratory as meeting the requirements in UL 1113. All four of the vessel’s electric bilge pumps are not UL rated. Replace installed bilge pumps with UL rated bilge pumps.
46 CFR 182.520(e)(1)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 July 2022
Resolved 21 June 2022
Resolution: UL rated bilge pumps provided.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 8 June 2022
Resolved
The following spaces must be equipped with a fixed fire extinguishing system, in compliance with 181.410, or other fixed fire extinguishing system specifically approved by the Commandant, except as otherwise allowed by paragraph (b) of this section: A space containing a fuel tank for gasoline or any other fuel having flash point of 110 degree F or lower. The fuel tank space is not protected by fixed fire extinguishing system. Install fixed fire extinguisher system that meets this sub part to the satisfaction of the attending USCG Marine Inspector
46 CFR 181.400
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 July 2022
Resolved 8 June 2022
Resolution: Issued in error. Work Instruction allows for not having fire extinguishing for fuel tank if conditions are met. This vessel meets those conditions.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 8 June 2022
Resolved
A mechanical exhaust system consisting of at least two ventilation exhaust ducts located at the end of the space opposite from where the supply ducts are fitted, which extend to the lowest part of the bilge of the space on each side of the space, and which are led to one or more powered exhaust blowers. Vessel only has one powered intake ventilation fan and no exhaust ventilation. Install ventilation fans that meet this sub part to the satisfaction of the attending USCG Marine Inspector.
46 CFR 182.460(a)(1)(ii)
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 July 2022
Resolved 1 August 2022
Resolution: Vents for space installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 June 2021
Resolved
Lifejacket stowage marking missing. Number and identification of stowed items and their sizes must be marked in clearly legible letters and numbers on each storage container. Provide marking of lifejacket storage.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2021
Resolved 10 July 2021
Resolution: Stowage marked.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 June 2021
Resolved
Fuel shut off marking faded. Remote fuel shut off must be clearly marked. Provide new marking.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2021
Resolved 10 July 2021
Resolution: Fuel shut off marked.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 June 2021
Resolved
Blower time marking missing. A red warning sign at the switch must state that the blowers must be operated prior to starting the engines for the time sufficient to insure at least one complete air change of air in the space served. Provide signage.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2021
Resolved 10 July 2021
Resolution: Blower time marked.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 June 2021
Resolved
Nav light breaker/switch and spare switch/breaker nameplates are mixed up. Make Nav light switch have proper name plate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2021
Resolved 10 July 2021
Resolution: Plates switched.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 June 2021
Resolved
Drug EAP number not on vessel. Provide EAP number.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2021
Resolved 15 July 2021
Resolution: EAP number provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 June 2021
Resolved
Missing blower ignition interlock. Blower switch must be interlocked with the starting switch and the ignition switch so that the blowers are started before the engine started motor circuit or the engine ignition is energized.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2021
Resolved 10 July 2021
Resolution: Ignition interlock provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 September 2019
Resolved
Each life buoy must be clearly marked with the vessels name. The markings on the provided life buoy were faded and illegible. Provide new markings.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 13 September 2019
Resolved 13 September 2019
Resolution: The provided life buoy was properly marked prior to the insepction ending.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 31 August 2018
Resolved
Vessels on a LTD Coastwise route are required to maintain 12 approved distress signals. Only 7 were provided on board. Provide the required number/combination of approved flares.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 September 2018
Resolved 31 August 2018
Resolution: The required number of flares were provided before the inspection concluded.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 31 August 2018
Resolved
Masters of vessels with EPIRBs installed are required to replace the battery of the EPIRB prior to teh expiration date required by the FCC. This vessels EPIRBs battery has expired. Provide a new battery for the EPIRB.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 September 2018
Resolved 11 September 2018
Resolution: A new registered EPIRB with a good battery was installed.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 31 August 2018
Resolved
Each disposable hydrostatic release must be replaced 2 years after the installation date. The installed hydrostatic release for the EPRIB is expired. Provide a new hydrostatic release for the EPIRB.
Action required: 705 - Other - as specified
Due 14 September 2018
Resolved 31 August 2018
Resolution: A new hydrostatic release was installed prior to the inspection concluding.