MAURY USCG vessel records
← All vessels

AVAX

AVAX is a 2006 freight ship. The Coast Guard has recorded 9 inspections since 2016, most recently in February 2025, along with 4 deficiencies — 1 with no resolution recorded — and 2 operational controls.

Records from 2016 to 2025. Most recent: inspection, 3 February 2025.

Built
2006
Last inspected
3 February 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 3 February 2025
…with no type recorded1
…past their stated due date1
Operational controls None recorded without a removal date
Years with a record 5 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9289312
912970
Flag
CYPRUS
Maury page id
psix-912970

Documentation record

Tonnage as PSIX records it41059 - Convention (Subpart B), Gross Ton
25433 - Convention (Subpart B), Net Ton
87031 - Displacement, Metric Ton
75399 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 9

3 February 2025 PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8073537
29 March 2024 PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7881038
22 March 2024 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7883685
14 August 2020 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7027723
6 November 2017 MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6300478
1 November 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6299252
27 October 2017 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6291794
24 October 2017 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6293957
4 January 2016 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5787469

Deficiency record · 4

07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 3 February 2025 Resolved
Means shall be provided to control leaks of flammable liquids. PSCO observed a fuel oil leak from a high pressure fuel line on main engine cylinder #2. 74SOLAS(09) II-2/4.1.1 Code 10C
Action required: 10 - Deficiency Rectified
Resolved 3 February 2025
Resolution: PSCO confirmed proper rectification of deficiency during PSC exam.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 3 February 2025 Resolved
The following fire detection systems shall be kept in good order so as to ensure their required performance if a fire occurs; fire detection and fire alarm systems. PSCO observed an inoperable flame detector in the purifier space. 74SOLAS(09) II-2/14.2.1.1.2 Code 10C
Action required: 10 - Deficiency Rectified
Resolved 3 February 2025
Resolution: PSCO confirmed proper rectification of deficiency during PSC exam.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 March 2024 No resolution recorded
The Load Line marks shall be plainly visible. The ring, lines and letters shall be painted in white or yellow on a dark ground or in black on a light ground. PSCO observed large amount of white paint missing from loadline on portside, making it hard to determing which load line was being used.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 1 August 2024 — due date passed with no resolution recorded
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 6 November 2017 Resolved
1730-oily-water separating equipment- Any ship of 10,000 gross tonnage and above shall be fitted with oil filtering equipment complying with paragraph 7 of this regulation. PSCO witnessed four operational tests of OWS. During each test, the OCM showed error of E3 after approximately 1.5 minutes of run time. PSCO was unable to witness OWS pump draw suction from bilge holding tank. Crew was unable to show system operating properly. MARPOL 74/78 Annex I/14 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 November 2017
Resolved 8 November 2017
Resolution: Received, reviewed and accepted class report from DNV-GL stating the deficiency was rectified. Error code was due to vacuum loss. Issue was corrected and class witness proper operational test.

Ownership record