AVAX is a 2006 freight ship. The Coast Guard has recorded 16 inspections since 2008, most recently in February 2025, along with 9 deficiencies — 1 with no resolution recorded — and 4 operational controls.

Records from 2008 to 2025. Most recent: inspection, 3 February 2025.

Built
2006
Last inspected
3 February 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9289312 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
912970
Flag
CYPRUS
—
Maury page id
psix-912970

Inspections, by type

…with no type recorded3
…past their stated due date1
Years with a record 9 calendar years (2008–2025)
The 16 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it41059 - Convention (Subpart B), Gross Ton
25433 - Convention (Subpart B), Net Ton
87031 - Displacement, Metric Ton
75399 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 16

3 February 2025 PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8073537
29 March 2024 PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7881038
22 March 2024 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7883685
14 August 2020 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7027723
6 November 2017 MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6300478
1 November 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6299252
27 October 2017 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6291794
24 October 2017 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6293957
4 January 2016 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5787469
19 August 2014 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4952483
17 February 2012 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4242084
8 September 2010 Administrative Inspection · Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3845160
15 November 2008 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3363735
12 November 2008 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3360924
12 November 2008 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3362077
27 October 2008 ISPS II Exam · PII Safety Exam · Ballast Water Examination · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3347163

Deficiency record · 9

07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 3 February 2025 Resolved
Means shall be provided to control leaks of flammable liquids. PSCO observed a fuel oil leak from a high pressure fuel line on main engine cylinder #2. 74SOLAS(09) II-2/4.1.1 Code 10C
Action required: 10 - Deficiency Rectified
Resolved 3 February 2025
Resolution: PSCO confirmed proper rectification of deficiency during PSC exam.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 3 February 2025 Resolved
The following fire detection systems shall be kept in good order so as to ensure their required performance if a fire occurs; fire detection and fire alarm systems. PSCO observed an inoperable flame detector in the purifier space. 74SOLAS(09) II-2/14.2.1.1.2 Code 10C
Action required: 10 - Deficiency Rectified
Resolved 3 February 2025
Resolution: PSCO confirmed proper rectification of deficiency during PSC exam.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 March 2024 No resolution recorded
The Load Line marks shall be plainly visible. The ring, lines and letters shall be painted in white or yellow on a dark ground or in black on a light ground. PSCO observed large amount of white paint missing from loadline on portside, making it hard to determing which load line was being used.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 1 August 2024 — due date passed with no resolution recorded
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 6 November 2017 Resolved
1730-oily-water separating equipment- Any ship of 10,000 gross tonnage and above shall be fitted with oil filtering equipment complying with paragraph 7 of this regulation. PSCO witnessed four operational tests of OWS. During each test, the OCM showed error of E3 after approximately 1.5 minutes of run time. PSCO was unable to witness OWS pump draw suction from bilge holding tank. Crew was unable to show system operating properly. MARPOL 74/78 Annex I/14 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 November 2017
Resolved 8 November 2017
Resolution: Received, reviewed and accepted class report from DNV-GL stating the deficiency was rectified. Error code was due to vacuum loss. Issue was corrected and class witness proper operational test.
Engineering › Steering Gear System › Piping
Issued 19 August 2014 Resolved
9800 - xxx - The vessel must have a fixed storage tank having sufficient capacity to recharge at least one power actuating system including the reservoir. A vessel does not have the storage tank required by SOLAS 74 (amended) II-1/29.12.3.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 August 2014
Resolved 12 September 2014
Resolution: PSC NOLA received proper documentation from the vessel satisfying the requirement.
Documentation › Logs/Records › Oil Record Book
Issued 17 February 2012 Resolved
1710- Oil Record Book - Each operation listed in 3.1 of IOPP shall be fully record without delay in the ORB. C/E had not been logging the weekly sounding for the Fuel oil overflow tank. C/E stated they tank is never used, so it doesn't need to be recorded. PSCO sounded the tank which was at 11.436 m3. -MARPOL Annex I/17
Action required: 17 - Rectify deficiencies prior to departure
Due 17 February 2012
Resolved 21 February 2012
Resolution: Received, reviewed, and accepted class report from Germanischer Lloyd, Cyprus, and EFNAV Company Ltd stating that all outstanding deficiencies have been rectified.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 17 February 2012 Resolved
1799- Other (MARPOL) - C/E could not provide an understandalbe reason as to why the fuel oil overflow tank is gaining fuel. -MARPOL Annex I/12
Action required: 17 - Rectify deficiencies prior to departure
Due 17 February 2012
Resolved 21 February 2012
Resolution: Received, reviewed, and accepted class report from Germanischer Lloyd, Cyprus, and EFNAV Company Ltd stating that all outstanding deficiencies have been rectified.
Lifesaving › Launching Appliances › Davit
Issued 17 February 2012 Resolved
0610- Lifeboats - Before the ship leaves port and at all times during the voyage, all lfie-saving appliances shall be in working order and ready for immediate use. During exam, the starboard side life boat davit system was non-operational. -SOLAS 74 (09 cons) III/20
Action required: 705 - Other - as specified
Due 17 February 2012
Resolved 17 February 2012
Resolution: PSCO gave the crew time to make necessary repairs, and after one hour, the crew was able to lower the lifeboat.
Engineering › Freshwater System (cylinder head cooling) › Fitting
Issued 27 October 2008 Resolved
The No. 7 cylinder for the M/E is leaking jacket water.
Action required: 705 - Other - as specified
Due 10 November 2008
Resolved 15 November 2008
Resolution: A class report was faxed to Sector LA/LB. Repairs have been completed. All satisfactory