MAURY USCG vessel records Sign in
← All vessels

CAMP HOLLY #1

CAMP HOLLY #1 is a 2007 passenger vessel (inspected). The Coast Guard has recorded 24 inspections since 2008, most recently in September 2025, along with 34 deficiencies and 2 operational controls.

Records from 2008 to 2025. Most recent: inspection, 12 September 2025.

Built
2007
Last inspected
12 September 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

913252
Flag
UNITED STATES
—
Maury page id
psix-913252

Inspections, by type

Years with a record 15 calendar years (2008–2025)
The 24 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it3 - Simplified, Gross Ton
2 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 24

12 September 2025 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8234836
2 December 2024 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8042161
28 February 2024 Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7871427
22 January 2024 Administrative Inspection · In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7852744
2 October 2023 Annual Inspection · Drydock Exam · Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7802015
6 September 2022 Deficiency Check · Drydock Exam · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7552921
15 September 2021 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7312720
20 November 2020 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7099277
13 November 2019 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6854950
26 October 2018 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6570126
11 September 2018 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6538106
4 October 2017 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6281318
22 September 2017 DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6275513
6 January 2016 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5791891
15 February 2012 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 4245165
25 January 2012 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 4231527
21 January 2011 Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3934282
6 January 2010 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3659701
16 December 2009 Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3651345
9 July 2009 Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3529061
29 April 2009 Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3463925
24 February 2009 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3422873
20 February 2009 Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3421050
20 February 2008 In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3150554

Deficiency record · 34

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 December 2024 Resolved
Exhaust gas must not leak from the piping or any connections. The piping must be properly supported by non combustible handers or blocks. The exhaust hanger on the stbd side has broken free fwd of the muffler and left a hole on the piping. The connecting piping to this section is also loose. The exhaust piping on the port side has a hole at the transom penetration. Repair the satisfaction of the attending MI. 46 CFR 182.430 (b) Code 50 c
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 January 2025
Resolved 22 December 2024
Resolution: Corrected
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 17 December 2024 Resolved
Gauges to indicate engine revolutions per minute, jacket water discharge temp. and lubricating oil pressure must be provided for all propulsion engines installed in the vessel. The gauges must be readily visible at the operating station. The lube oil pressure gauge is not working. Replace to the satisfaction of the attending MI. 46 CFR 182.410 (b) Code 50 c
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 January 2025
Resolved 22 December 2024
Resolution: New gauge installed.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 29 February 2024 Resolved
In applying the provisions of this subchapter, the OCMI may give special consideration to authorize departures from the specific requirements when unusual circumstances of arrangements warrant. Special consideration allowing solo operations has been removed and COI amended to reflect 1 Master and 1 deckhand. CG001 46 CFR 175.550
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 1 March 2024
Resolved 1 March 2024
Resolution: New COI issued.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 22 January 2024 Resolved
Whenever damage or deterioration to hull plating or structural members that may affect the seaworthiness of a vessel is discovered, the cognizant OCMI may....require the vessel to be drydocked or taken out of service to assess the extent of the damage, and to effect permanent repairs. Securing tabs under the transverse frames are broken and / or loose.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 January 2024
Resolved 26 January 2024
Resolution: Inspected repairs, all sat.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 January 2024 Resolved
Rails or equivalent protection must be installed near the periphery of all decks of a vessel accessible to passengers or crew. The rail is broken on the port side amidship.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 January 2024
Resolved 26 January 2024
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 January 2024 Resolved
Each portable fire extinguisher on a vessel must be of an approved type. The aft fire extingusher is not mounted properly.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 February 2024
Resolved 26 January 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 January 2024 Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 3 feet in length, but not more than 6 feet, securing the waterlight around the body of the ring life buoy. The line securing the buoy is not serviceable.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 January 2024
Resolved 26 January 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 January 2024 Resolved
All fuel tanks must be electrically bonded to a common ground. The bonding wire is not present.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 February 2024
Resolved 26 January 2024
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 October 2023 Resolved
Alcohol testing must be conducted on each individual engaged or employed on board the vessel who is directly involved in a Serious Marine Incident as defined in 46 CFR 4.03-2, the testing must be conducted with in 2 hours of the SMI unless precluded by safety concerns directly related to the incident. Vessel operator has no alcohol testing devices. Obtain a DOT alcohol testing device or strip to the satisfaction of the attending MI. 46 CFR 4.06-3 (a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2023
Resolved 11 October 2023
Resolution: New testing strips were provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 October 2023 Resolved
EAP training program: An EAP training program must be conducted for the employer's crewmembers and supervisory personnel. The training program must include at least the following elements: the effects and consequence of drug and alcohol use on personal health, safety and work environment; the manifestation and behavioral cues that may indicate drug and alcohol use and abuse and documentation of training given to crewmembers and employers supervisory personnel. Supervisory personnel must receive at least 60 min. of training. Conduct training and document to the satisfaction of the attending MI. 46 CFR 16.401 (b)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2023
Resolved 11 October 2023
Resolution: Owner conducted training with crews.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 October 2023 Resolved
Fuel Oil - Flexible hose designed for use with hose clamps may be installed with two clamps. F/O line from tank to engine was only clamped with one clamp at the filter. Corrected on the spot. 46 CFR 182.720 (e)(3)(v)(B)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 3 October 2023
Resolution: Corrected.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 6 September 2022 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. Chine welds showed excessive porosity. Make all welds visible for inspection and provide repair proposal for identified areas showing excessive wastage.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 December 2022
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 6 September 2022 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. Repair four cracks identified on the stern and bow. In addition, make watertight bolt holes on rake.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 December 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 September 2022 Resolved
A vessel must be provided with a main steering gear that is: Of adequate strength and capable of steering the vessel at all service speeds. Repair cracked bushing on starboard air rudder.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 October 2022
Resolved 7 December 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 September 2022 Resolved
Each unpressurized fuel tank must be fitted with a vent pipe connected to the highest point of the tank. Replace cracked fuel tank vent hose.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 October 2022
Resolved 7 December 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 November 2020 Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Vessel did not have the child life jackets separate from the adult life jackets.
Action required: 705 - Other - as specified
Due 27 November 2020
Resolved 28 September 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 November 2020 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. The first aid kit onboard the vessel was expired.
Action required: 705 - Other - as specified
Due 27 November 2020
Resolved 1 December 2020
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 November 2020 Resolved
Except as otherwise provided in this section, rails or equivalent protection must be installed near the periphery of all decks of a vessel accessible to passengers or crew. On starboard side of vessel, lower chain link fencing stuck beneath seating and unable to close.
Action required: 705 - Other - as specified
Due 27 November 2020
Resolved 1 December 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 November 2020 Resolved
In systems and applications where flexible hoses are permitted to be clamped: two clamps must be used on each end of the hose, or one hose clamp can be used if the pipe ends are expanded or beaded to provide a positive stop against hose slippage.Vent line only had one clamp.
Action required: 705 - Other - as specified
Due 27 November 2020
Resolved 1 December 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 November 2020 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection. Rudder stock tube on air rudder cracked.
Action required: 705 - Other - as specified
Due 27 November 2020
Resolved 1 December 2020
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 11 September 2018 Resolved
Spider cracking of hull plating on the port side fwd was discovered during annual inspection. Owner shall submit repair proposal addressing cracking prior to commencing repairs and NLT 11OCT18.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 October 2018
Resolved 26 October 2018
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 22 September 2017 Resolved
Install 30x30 mesh flame screen on fuel tank vent line.
Action required: 705 - Other - as specified
Due 22 September 2017
Resolved 4 October 2017
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 22 September 2017 Resolved
Provide 11 adult and 2 child size PFD's.
Action required: 705 - Other - as specified
Due 22 September 2017
Resolved 4 October 2017
Lifesaving › Lifebuoys › Serviceable
Issued 22 September 2017 Resolved
Provide new ring buoy.
Action required: 705 - Other - as specified
Due 22 September 2017
Resolved 4 October 2017
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 22 September 2017 Resolved
Provide proper 1st aid kit.
Action required: 705 - Other - as specified
Due 22 September 2017
Resolved 4 October 2017
Electrical › Electrical Distribution System (service) › Panelboard
Issued 25 January 2012 Resolved
Provide operable voltmeter.
Action required: 705 - Other - as specified
Due 8 February 2012
Resolved 15 February 2012
Engineering › Bilge Water Management System › Pump
Issued 25 January 2012 Resolved
Provide 5 GPM bilge pump.
Action required: 705 - Other - as specified
Due 8 February 2012
Resolved 22 February 2012
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 16 December 2009 Resolved
Replace/repair broken stern light. Vesel is restricted to day light only hours until light repaired.
Action required: 705 - Other - as specified
Due 16 January 2010
Resolved 6 January 2010
Engineering › Fuel Oil Service System › Hose
Issued 16 December 2009 Resolved
Double clamp all fuel hoses.
Action required: 705 - Other - as specified
Due 16 January 2010
Resolved 6 January 2010
Lifesaving › Hand Flares › Quantity
Issued 16 December 2009 Resolved
Provide two additional CG approved hand flares.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 December 2009
Resolution: Master of vessel faxed proof of purchase for two additonal flares.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 20 February 2009 Resolved
Child size life jacket location shall be properly labeled/stenciled NLT 20MAR09.
Action required: 705 - Other - as specified
Due 20 February 2009
Resolved 24 February 2009
Resolution: Corrected
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 20 February 2009 Resolved
Ring buoy shall be replaced, provided with retroreflective tape, and waterlight shall be made operable prior to operating.
Action required: 705 - Other - as specified
Due 20 February 2009
Resolved 24 February 2009
Resolution: Corrected
Documentation › Certificates/Documents › Stability Letter
Issued 20 February 2009 Resolved
Vessels registration was found to be expired - renewal required prior to operating.
Action required: 705 - Other - as specified
Due 20 February 2009
Resolved 24 February 2009
Resolution: Corrected
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 20 February 2009 Resolved
All fuel lines are to be double clamped NLT 20MAR09.
Action required: 705 - Other - as specified
Due 20 February 2009
Resolved 24 February 2009
Resolution: Corrected

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.