Registered dimensions (L × B × D)42.3 ft × 15.1 ft × 4.6 ft
Registered tonnagegross 27 / net 18
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWALKER BOAT YARD INC · PADUCAH KY, UNITED STATES · built 1966
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portST LOUIS, MO
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 6 September 2025 · expires 30 September 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it27 - Regulatory (Subpart C or D), Gross Ton 18 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1980 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 9
13 January 2026DAPI Audit
Administrative · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 8295917
13 January 2026Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 8296315
1 May 2024Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7905155
28 February 2023Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7643944
2 February 2022Administrative Inspection · Initial Certification
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7404087
1 December 2021Administrative Inspection
Administrative · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7360126
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 1 May 2024Resolved
All bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar as practicable. Aft void has accumulated oily water mixture. Remove oily water mixture to the satisfaction of an attending Marine Inspector.
46 CFR 142.220(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2024
Resolved 7 June 2024
Resolution: Oily water has been removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 1 May 2024Resolved
The following systems must be equipped with gauges at the machinery space: Main engine cooling water temperature. Main engine cooling water gauge is non operational. Repair/replace gauge to the satisfaction of an attending Marine Inspector.
46 CFR 143.230(c)(2)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2024
Resolved 1 May 2024
Resolution: Installed gauge was working properly
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 February 2023Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. The bilge pump electrical wiring under the main engine was observed with splices, broken insulation, and exposed conductors. Repair/renew to the satisfaction of an attending Marine Inspector.
46 CFR 143.400(a)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 March 2023
Resolved 26 April 2023
Resolution: Wiring repaired
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 28 February 2023Resolved
Each remote valve control must be marked in clearly legible letters, at least 25 millimeters (1 inch) high, indicating the purpose of the valve and the way to operate it. The remote fuel oil shut off valve on deck was not labeled. Label to the satisfaction of an attending Marine Inspector.
46 CFR 143.260(e)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 March 2023
Resolved 26 April 2023
Resolution: Labeling installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 28 February 2023Resolved
The following systems must be equipped with gauges at the machinery location: (1)Main engine lubricating oil pressure and main engine RPM (2)Main engine cooling water temperature (3)Auxiliary generator engine lubricating oil pressure and auxiliary generator engine RPM (4) Auxiliary generator engine cooling water temperature. Main engine/ Generator engine were not equipped with any gauges in the machinery location. Install gauges to the satisfaction of an attending Marine Inspector.
46 CFR 143.230(c)(1)-(4)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 March 2023
Resolved 26 April 2023
Resolution: Gauges installed
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 February 2023Resolved
Each life jacket must be marked: With Type I retro-reflective material approved under approval series 164.018. The arrangement of the retro reflective material must meet IMO Resolution A.658(16). The retro reflective material on the life jacket located in the wheel house is no longer serviceable. Replace life jacket or repair retro reflective material to the satisfaction of an attending Marine Inspector.
46 CFR 141.340(f)(2)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 March 2023
Resolved 26 April 2023
Resolution: New PFD provided.
All owners and operators of an existing towing vessel must have a valid COI prior to the specified phase-in period. This vessel is one of the associated fleet that has not obtained a valid COI. The vessel shall be made available for a Coast Guard COI inspection within 90 days. If an inspection is not completed prior to this date, the action for this deficiency shall be changed to a 60 (Rectify deficiencies prior to movement) and the vessel may no long be permitted to operate.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 1 January 2022
Resolved 23 February 2022
Resolution: Vessel received COI.