Records from 2016 to 2024. Most recent: inspection, 30 July 2024.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 30 July 2024
Resolved
Means shall be provided to control leaks of flammable liquids. PSCO observed fuel oil leak on M/E cylinder No. 5 around cylinder head near fuel injectors and on cylinder No. 2 from high pressure fuel line connect to fuel oil pump.
74SOLAS(09) 11-2/4.1.1
17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 August 2024
Resolution: O-rings and copper rings were renewed by the crew and all leaks were cleared by the crew
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 July 2024
Resolved
The machinery, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. PSCO observed air bubbles coming from M/E cylinder No. 7 cylinder liner connection to M/E block.
74SOLAS(04)II-1/26.1
50ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 August 2024
Resolved 1 August 2024
Resolution: Class surveyor observed that there were no bubbles/water between the M/E cylinder No. 7 cylinder liner and M/E block when the jacket water was heated to around 79 degrees centigrade.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 30 July 2024
Resolved
Every steam pipe and every fitting connected thereto through which steam may pass shall be so installed as to withstand maximum working stresses. PSCO observed steam leak from No. 2 L/O purifier heater steam inlet valve connection.
74SOLAS(04) II-1/33.1
50ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 August 2024
Resolved 1 August 2024
Resolution: No.2 L/O purifier heater steam inlet valve was separated and the gasket was renewed by the crew member. Condition was checked by class surveyor.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 July 2024
Resolved
After any survey of the ship under regulation 10 has been completed, no change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey without the sanction of the Administration. PSCO observed portable fans being used to cool control air compressor unit and service air compressor unit.
74SOLAS(20) I/II(a)
50ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 August 2024
Resolved 1 August 2024
Resolution: Fans were removed and operating temp was checked by class surveyor.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 July 2024
Resolved
The machinery, associated piping systems and fittings shal be of a design and construction adequate for the service for which they are intended. PSCO observed minor jacket water leak from M/E cylinder No. 3.
74SOLAS(04) II-1/26.1
40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 August 2024
Resolution: Class surveyor stated that there was no leaked water around the M/E cylinder No.3 when the jacket water was heated to around 79 degrees centigrade
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 July 2024
Resolved
The machinery, associated piping systems, and fittings shall be of a design and construction adequate for the service for which they are intended. PSCO observed modified drip pan/line diverting fresh water leak from M/E jacket cooling water line temperature regulating valve.
74SOLAS(04) II-1/26.1
40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 August 2024
Resolution: Valve was dismantled and o-rings and gaskets were renewed by crew members. Satisfactory operational test of valve was witness by class surveyor with no leaks.
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 6 September 2020
Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. Emergency fire pump did not discharge from either fire hoses after 10 minutes of operation.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 September 2020
Resolution: Function test of the emergency fire pump was caried out with the witness and the undersigned surveyor and found satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 September 2020
Resolved
Two lifebuoys shall be provided with self-activating smoke signals and be capable of quick release from the bridge. The ring buoy's smoke signal was not installed in accordance with manufacturer's instructions.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 September 2020
Resolution: Lifebuoy was installed according to manufacturer.