MAURY USCG vessel records
← All vessels

ISLAND GIRL

ISLAND GIRL is a 2000 passenger vessel (inspected). The Coast Guard has recorded 21 inspections since 2016, most recently in September 2025, along with 15 deficiencies and 1 casualty investigation in 2010.

Records from 2010 to 2025. Most recent: inspection, 8 September 2025.

Built
2000
Last inspected
8 September 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 8 September 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDF2897
Flag
UNITED STATES
Maury page id
psix-9153

Documentation record

Registered dimensions (L × B × D)80.8 ft × 20.0 ft × 6.0 ft
Registered tonnagegross 64 / net 51
ITC dimensions (L × B × D)80.8 ft × 20.0 ft × 6.0 ft
ITC tonnagegross 169 / net 61
BuilderSKIPPERLINER INDUSTRIES INC · LA CROSSE, WI, UNITED STATES · built 2000
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portMARCO ISLAND, FL
Trade endorsementsCoastwise, unrestricted, Recreational, Registry
DocumentationValid · issued 30 July 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it169 - Convention (Subpart B), Gross Ton
64 - Regulatory (Subpart C or D), Gross Ton
61 - Convention (Subpart B), Net Ton
51 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 21

8 September 2025 Examination of Repairs · Deficiency Check · Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8228651
29 July 2025 Deficiency Check · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8196323
18 June 2024 Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7936937
6 September 2023 Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7784897
23 May 2023 COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7693926
13 October 2022 Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7576866
19 September 2022 Examination of Repairs
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7562088
9 August 2022 Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7528066
10 September 2021 Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7308332
14 July 2021 Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7254503
14 October 2020 In-Service Inspection · Deficiency Check · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7076066
20 August 2020 Examination of Repairs
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7075945
14 July 2020 Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7001374
27 February 2020 Type not recorded
No type recorded · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6916955
17 September 2019 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6809528
29 July 2019 Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6744456
15 August 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6512843
20 May 2018 Administrative Inspection · COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6418803
15 September 2017 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6267936
10 July 2017 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6175452
21 July 2016 Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5933136

Deficiency record · 15

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 July 2025 Resolved
Ventilation of spaces containing diesel machinery. Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. The port and starboard manual ventilation dampers for the engine compartment are seized, do not sufficiently seal when closed, and are considered non-functional. Make permanent repairs to the port and starboard ventilation dampers IAW original design plan review approval specifications to the satisfaction of the attending CG Marine Inspector. 46CFR182.465(h)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 July 2025
Resolution: Made permanent repairs to the port and starboard ventilation dampers. The port and starboard manual ventilation dampers for the engine compartment are no longer seized, and sufficiently seal when closed, and are now considered functional.
09 - Working and Living Conditions › 091 - Living Conditions › Galley, handlingroom (maintenance)
Issued 29 July 2025 Resolved
A grease extraction hood must be equipped with a dry or wet chemical fire extinguishing system meeting the applicable sections of NFPA 17 or NFPA 17A (both incorporated by reference, see 46 CFR 175.600). A servicing report from Global Fire Inc, 20 Colonial Drive, Naples, FL 34112, for the fixed fire extinguishing system, located at the galley hood, dated 03/12/2025, serial number 31547 states the following: Ansul R-102 Wet Chemical Fire Suppression System cartridge and actuation hose is overdue for a hydrostatic pressure test. Prior to using galley appliances, provide to the CG Marine Inspector, updated servicing report of completed required system maintenance and recertification of the system IAW manufacturer's specifications and NFPA 17. 46CFR181.425
Action required: 705 - Other - as specified
Resolved 30 July 2025
Resolution: Report from Global Fire Inc, Naples, FL 34112, for the galley hood dated 30JUL2025, serial number 31949: "performed hydrostatic test on 3 gal tank, refilled with agent, replaced actuation hose and actuation cartridge, recertified the system".
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 29 July 2025 Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. essel is unable to complete the VHF Radio Digital Selective Calling (DSC) Test. Complete the VHF Radio Digital Selective Calling (DSC) Test IAW MSIB 20-20. 46CFR176.840
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 August 2025
Resolution: Vessel completed the VHF Radio Digital Selective Calling (DSC) Test IAW MSIB 20-20.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 July 2025 Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located. The fuel tank shut down valve linkage is not adequately secured. Secure the fuel tank shut down valve linkage to the satisfaction of the attending CG Marine Inspector. 46CFR182.455(b)(4)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 July 2025
Resolution: The fuel tank shut down valve linkage is now adequately secured and properly functioning.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 29 July 2025 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. IAW Rescue Platform MPS-WI-SECSP(spi)-14, The platform, when deployed, must be parallel to the water without breaking the surface. The platform when deployed is not parallel to the water, and is submerged. Make permanent repairs to the rescue platform to the satisfaction of the attending CG Marine Inspector. 46CFR176.830(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 August 2025
Resolution: IAW Rescue Platform MPS-WI-SECSP(spi)-14, The platform, when deployed, is now parallel to the water without breaking the surface.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 18 June 2024 Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessel's stability letter, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 25 millimeters (1 inch) numbers and letters at the entranceway to that deck. Passenger capacity marking missing on interior and exterior entranceway to second deck. Add markings to satisfaction of attending CG Marine Inspector. 46CFR185.602
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2024
Resolved 25 June 2024
Resolution: Passenger capacity markings added on interior and exterior entranceway to second deck.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 June 2024 Resolved
Each rescue boat and ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. The arrangement of the retro-reflective material applied after March 11, 1996, must be as specified by IMO Resolution A.658(16). Three ring life buoys are insufficiently marked with retro-reflective material. Mark three ring life buoys with retro-reflective material to the satisfaction of attending CG Marine Inspector. 46CFR185.604(i)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2024
Resolved 25 June 2024
Resolution: Three ring life buoys are now sufficiently marked with retro-reflective material.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 18 June 2024 Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. Engine space ventilation closure is not labeled with the open or closed position. Label the engine space ventilation closures with open and closed position to the satisfaction of the attending CG Marine Inspector. 46CFR182.465
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2024
Resolved 25 June 2024
Resolution: Engine space ventilation closure are now labeled with the open or closed position.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 18 June 2024 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. The following unsafe practices and hazards were ID'd during the annual inspection: Battery charger exposed electrical connection in steering compartment, Stern thruster exposed electrical connection, inadequate harness for MOB/Rescue platform, improperly secured soda CO2 bottles. Correct the unsafe practices and hazards to the satisfaction of the attending CG Marine Inspector. 46CFR176.830
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2024
Resolved 25 June 2024
Resolution: Battery charger exposed electrical connection in steering compartment corrected, Stern thruster exposed electrical connection corrected, now has adequate harness for MOB/Rescue platform, now properly secured soda CO2 bottles.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 14 July 2021 Resolved
Repair wasted sections of longitudinal deck frames - port and starboard - IWO sewage tank by next scheduled dry dock in September 2021.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 September 2021
Resolved 20 September 2021
Resolution: Plate and associated frames replaced. See activity 7308332 and documents for details.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 14 July 2020 Resolved
Vessel FCC certificates are expired. Renew and provide proof of FCC certificates in good standing.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2020
Resolved 17 July 2020
Resolution: Owner provided proof of obtaining good standing FCC certificates.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 July 2020 Resolved
Several non-metallic flex hoses on the vessel used for oil service are not approved, needing replacement. Add chaffing gear and replace specified hoses.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2020
Resolved 15 October 2020
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 15 August 2018 Resolved
Vsl is broadcasting: Invalid Call Sign, incorrect Name, and measure length in FT (Vsl dimension Must be measured in meters).
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 September 2018
Resolved 9 August 2022
Resolution: AIS Updated
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 10 July 2017 Resolved
Conspicuously mark spaces protected by CO2 fixed system. (46 CFR 185.612)
Action required: 705 - Other - as specified
Due 24 July 2017
Resolved 24 July 2017
Resolution: marked spaces protected by CO2 with proper placards.
Navigation › Piloting/Steering › Marine Charts
Issued 21 July 2016 Resolved
Chart on board is for recreational use. provide current chart of large enough scale to make safe navigation possible for commercial vessels.
Action required: 705 - Other - as specified
Due 4 August 2016
Resolved 28 July 2016
Resolution: Bought new chart.

Casualty record · 1

31 January 2010Routine · role: Involved in a Marine Casualty · activity 3677337
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.