← All vessels
IVESTOS 3
IVESTOS 3 is a 2007 freight ship. The Coast Guard has recorded 8 inspections since 2007, most recently in November 2020, along with 13 deficiencies and 2 operational controls.
Records from 2007 to 2020. Most recent: inspection, 4 November 2020.
- Built
- 2007
- Last inspected
- 4 November 2020
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 13 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9349320 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V7ED9
916429
Flag
MARSHALL ISLANDS
—
Maury page id
psix-916429
Inspections, by type
…with no type recorded1
Years with a record
6 calendar years (2007–2020)
The 8 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it40488 - Convention (Subpart B), Gross Ton
25884 - Convention (Subpart B), Net Ton
74456 - Dead Weight, Metric Ton
25884 - Convention (Subpart B), Net Ton
74456 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 8
4 November 2020
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7089783
19 October 2017
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6284453
29 October 2016
PII Safety Exam · Deficiency Check · ISPS II Exam · Ballast Water Examination · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6027248
26 October 2016
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6041041
17 December 2009
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3678648
14 December 2009
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3649705
18 September 2008
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3327237
12 September 2007
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3055928
Deficiency record · 13
Lifesaving › Launching Appliances › Davit
Issued 19 October 2017
Resolved
Each survival craft shall be stowed: in a state of continuous readiness so that two crew members can carry out preparations for embarkation and launching in less than 5 min. While attempting to lower the starboard side lifeboat to the embarkation deck, PSCO observed an excessive amount of pain covering the entire lifeboat davit launching appliance, inhibiting the crew from launching the lifeboat for at least 20 minutes.
Fire Fighting › Fixed Fire Detection System › Approval
Issued 19 October 2017
Resolved
The function of fixed fire detection and fire alarm systems shall be periodically tested to the satisfaction of the Administration by means of equipment producing hot air at the appropriate temperature, or other listed means. The Chief Engineer was unable to produce proper testing equipment for the fixed fire detections and fire alarm systems.
Fire Fighting › Fire Hoses › Number
Issued 19 October 2017
Resolved
In cargo ships: of 1,000 gross tonnage and upwards, the number of fire hoses to be provided shall be one for each 30m length of the ship and one spare, but in no case less than five in all. During a test of the emergency fire pump, the forward fire hose suffered catostrophic failure. Ship does not meet the required number of fire hoses now.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 19 October 2017
Resolved
General arrangement plans shall be permanently exhibited for the guidance of the ship’s officers, showing clearly for each deck the control stations, the various fire section enclosed by “A” class division. Vessel’s crew drilled hole into the fire boundary of the engine room thus jeopardizing the integrity of the fire boundary.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 19 October 2017
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulation to ensure that the ship in all respect will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed that two self closing fire doors did not self close.
One door was on the main stairway on the 2nd deck and the other was leading from the galley to the main passageway.
Fire Fighting › Nozzles › Condition
Issued 19 October 2017
Resolved
Nozzles shall be of an approved dual-purpose type incorporating a shutoff. During test of fire hoses, 01 nozzel siezed and was not operational.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 19 October 2017
Resolved
Muster and embarkation stations shall be adequately illuminated by lighting supplied from the emergency source of electrical power required by regulation II-1/42 or II-1/43, as appropriate. 05 bulbs in embarkation and muster areas were inoperable.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 19 October 2017
Resolved
Every company should develop, implement and maintain a safety management system which includes the following functional requirement: Instructions and procedures to ensure safe operation of ships and protection of the environment in compliance with relevant international and flag and state legislation. In accordance with the Ship's Safety Management System the vessel is required to ensure all manufacturers' maintenance manuals are readily available on Critical Equipment. PSCO requested testing procedures for the fire detection system which is Critical Equipment. The Chief Engineer stated that there was no manual on board. In addition to that, the last three months of Critical Equipment checks were not signed by any of the appointed Officers.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 29 October 2016
Resolved
1740- oil discharge mon/contr system- Oil filtering equipment shall be of a design approved by the Administration and shall be such as will ensure that any oily mixture discharged into the sea after passing through the system has an oil content not exceeding 15ppm. Crew was unable to perform the functional test indicated in the user manual. The OCM does not display the live oil concentration as de
Fire Fighting › Automatic Sprinkler System › Power Sources
Issued 29 October 2016
Resolved
0725 – Fixed fire extinguishing installation – Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. Hyper-mist system was switch to manual mode, rendering the system incapable of being started automatically. This disables the system's quick response capability and reduces its effectiveness. Administration approved the vessel for unattend
Fire Fighting › Fixed Fire Detection System › Power Supply
Issued 29 October 2016
Resolved
0715 – Detection - A fixed fire detection required in this regulation and other regulations in this part shall be of an approved type and comply with the Fire Safety Systems Code. The second source of power (battery) in the fire detection system was found depleted, holding a weak charge, causing a fault in the system. '74 SOLAS '04 II-2 7.2.2
Engineering › Lubricating Oil Service System › Pump
Issued 29 October 2016
Resolved
0999 – Other (Safety in General) - The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO noted containers and rags used as a way of controlling leaks from valves and other fittings.74 SOLAS 14 I/11(a)
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 14 December 2009
Resolved
SOLAS 74A II-1/ 43When conducting an operational test of the emergency generator, it was observed that the gage for the Hz was only reading 55Hz. 3rd engineer said that it normally runs at 60Hz. Then a load test was conducted with the following results: Hz less then 55, A - 50, Kw - 30 and V- 405. Class to attest to proper calibration of all emergency generator gages.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.