MAURY USCG vessel records
← All vessels

HC EVA-MARIE

HC EVA-MARIE is a 2007 public freight. The Coast Guard has recorded 23 inspections since 2016, most recently in July 2025, along with 11 deficiencies and 4 operational controls.

Records from 2016 to 2025. Most recent: inspection, 20 July 2025.

Built
2007
Last inspected
20 July 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 20 July 2025
…with no type recorded6
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9369071
916450
Flag
ANTIGUA AND BARBUDA
Maury page id
psix-916450

Documentation record

Tonnage as PSIX records it7878 - Convention (Subpart B), Gross Ton
11121 - Dead Weight, Metric Ton
15102 - Displacement, Metric Ton
3909 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 23

20 July 2025 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8189832
16 July 2025 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8187149
18 March 2025 PSC B
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8093738
26 July 2024 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7967449
12 January 2024 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7848664
5 May 2023 PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7681814
3 April 2021 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7168034
29 March 2021 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7165517
27 December 2019 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6877396
25 December 2019 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6878311
12 September 2019 Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6809944
28 August 2019 In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6794784
22 August 2019 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6791511
25 October 2018 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6565789
14 September 2017 Deficiency Check · In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6266853
14 September 2017 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6332413
12 September 2017 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6265164
30 July 2017 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6222470
24 July 2017 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6218935
21 July 2017 Deficiency Check · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6216113
5 July 2016 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5913264
2 July 2016 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5929932
2 July 2016 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5936938

Deficiency record · 11

14 - Pollution Prevention › 141 - MARPOL Annex I › Oil and oily mixtures from machinery spaces
Issued 18 March 2025 Resolved
Each operation described in paragraph 2 of this regulation shall be fully recorded without delay in the Oil Record Book Part 1, so that all entries in the book appropriate to that operation are completed. PSCO observed an increase in the contents of the sludge tank when reviewing the Oil Record Book without a corresponding entry to explain the increase.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 18 March 2025
Resolved 18 March 2025
Resolution: Vessel identified to the Coast Guard's satisfation that it was the previous Chief Engineer that was not making proper Oil Record Book log entries and that the current engineer was maintaining proper log entries.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 18 March 2025 Resolved
In Cargo ships, the failure of such gauges or overfilling of the tank shall not permit release of fuel into the space. The Administration may permit the use of oil-level gauges with flat glasses and self-closing valves between the gauges and fuel tanks. PSCO observed hold back devices on self closing valves above and below sight glasses.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 18 March 2025
Resolved 18 March 2025
Resolution: Chief engineer removed hold-back devices on the self closing valves above and below all sight glasses.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Documentation-ISM
Issued 18 March 2025 Resolved
The Safety Management System shall be maintained in accordance with the provisions of the International Safety Management Code. Vessel SMS requires log book keeping to include the Oil Record Book. PSCO observed discrepencies in the Oil Record Book due to missing log entries. Recommend 3rd Party ISM Audit of vessel's SMS.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 July 2025
Resolution: Vessel submitted Class BV ISM Audit report. ISM Audit was conducted as recommended.
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 14 September 2017 Resolved
On 14SEP17, it was reported to USCG Sector Houston that there was a shipboard oil spill incident that subsequently led to several gallons of oil on deck and in the waters of the U.S. Reports from the vessel indicated that there was either a mechanical failure of the valve between the port and starboard fuel tanks or that there was a mis-alignment of the valve that led to the pollution incident.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 14 September 2017
Resolved 16 September 2017
Resolution: SEC HOU-GAL PSC received a class report from RINA satisfying the requirement. Examiners conducted a deficiency check exam on the vessel to verify the deficiency was rectified.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Valves
Issued 24 July 2017 Resolved
0725- PSCO observed MINIFOG hyper mist system fresh water suction valve in the closed position, rendering the system incapable of fighting a fire in high risk areas in the engine room. Vessel is classed for and operates in unmanned mode as per the Engine Log Book.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 July 2017
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 24 July 2017 Resolved
2535- Monthly hyper mist inspection checklist completed 30JUN17 indicated the readiness of the hypermist system in working order, despite objective evidence of manual suction supply valved observed in the closed position. SMS does not include testing or disabling procedures to prevent inadvertant closure of the suction supply valve.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 July 2017
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 24 July 2017 Resolved
0750- Self-closing fire doors observed inhibited and inoperable in the following locations: poop deck stairwell, main deck stairwell, galley, and engine room entrance.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 July 2017
Resolution: Self-closing devices on doors have been repaired and are in good working condition
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 24 July 2017 Resolved
0899- The nonslip deck surface in the steering gear compartment observed in poor material condition, inhibiting its accident preventative capability.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 July 2017
Resolution: The Damaged non slip mat is steering gear compartment has been replaced with a new one inch thick rubber mat available on board. The new rubber mat is providing good non slip surface in steering gear compartment
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 24 July 2017 Resolved
1581- Rudder angle indicators indicated over 5 degree disparity between steering gear and bridge displays.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 November 2017
Resolved 25 October 2018
Resolution: Reviewed tech report attesting to the replacement and proper operation of the rudder angle indicator.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 5 July 2016 Resolved
2120-Garbage-Every ship of 400 gross tonnage and above and every ship which is certified to carry 15 persons or more shall carry a garbage management plan which the crew shall follow. In accordance with garbage management plan section 4.5.5 all disposed , discharge or incineration shall be logged in the garbage record book. Crew did not record disposal of medical waste.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 21 July 2017
Resolution: SEC HOU-GAL PSC received a class report from RINA satisfying the requirement.
Engineering › Fuel Oil Service System › Valve
Issued 5 July 2016 Resolved
1499- Other (Prop & Aux. machinery) – The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulation to ensure the ship in all respect will remain fit to proceed to sea without danger to ship or crew. The valve on day tank 41b was leaking HFO. Repair to replace to the satisfaction of class. SOLAS 2014 Ch1 Reg 11.A
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 21 July 2017
Resolution: SEC HOU-GAL PSC received a class report from RINA satisfying the requirement.

Ownership record