MAURY USCG vessel records
← All vessels

SUNNY WILLIAMS

Built
2008
Last inspected
26 August 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 26 August 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDE4940
916523
Flag
UNITED STATES
Maury page id
psix-916523

Documentation record

Registered dimensions (L × B × D)84.6 ft × 27.0 ft × 10.0 ft
Registered tonnagegross 94 / net 64
ITC dimensions (L × B × D)84.6 ft × 27.0 ft × 10.0 ft
ITC tonnagegross 167 / net 50
BuilderC & G BOAT WORKS INC · MOBILE, AL, UNITED STATES · built 2008
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portWILMINGTON, DE
Endorsements, as the file codes themcw_un
DocumentationValid · issued 12 November 2025 · expires 31 December 2026
Service, as the file records itTank Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it167 - Convention (Subpart B), Gross Ton
344 - Displacement, Gross Ton
188 - Dead Weight, Gross Ton
94 - Regulatory (Subpart C or D), Gross Ton
50 - Convention (Subpart B), Net Ton
64 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 19 inspections, each with its date, unit and type; 5 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 19

26 August 2025 Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8217932
21 August 2024 MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7985873
9 August 2023 COI Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7757029
14 June 2023 Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7718877
8 June 2023 Load Line/Change of Employment
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7703586
4 August 2022 Annual Inspection · Deficiency Check · In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7518888
27 May 2022 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7460590
13 February 2022 Bulk Liquid Transfer Monitor
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7395608
16 October 2021 Bulk Liquid Transfer Monitor
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7334255
24 June 2021 Internal Structural Exam · Periodic Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7234112
20 July 2020 Annual Inspection · MTSA Verification
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7011546
19 June 2019 Annual Inspection · MTSA Verification
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6719431
18 October 2018 In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6568694
9 October 2018 Load Line/Change of Employment
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6557246
1 October 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6552298
11 July 2018 MTSA Verification · Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6475223
13 June 2018 Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6442916
11 July 2017 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6205112
22 June 2016 Internal Structural Exam · Periodic Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5915109

Deficiency record · 5

09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 20 July 2020 Resolved
Vessel missing lagging on port side main exhaust in way of turbo. 46 CFR 58.01-20
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 August 2020
Resolved 24 June 2021
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 20 July 2020 Resolved
Fire main gauge is not appropriate for pressure in fire main. Replaced on the spot. 46 CFR 34.10-5(b)
Action required: 10 - Deficiency Rectified
Due 20 July 2020
Resolved 20 July 2020
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 20 July 2020 Resolved
Liferaft painted line was not connected to float free arrangment. Corrected on the spot.
Action required: 10 - Deficiency Rectified
Due 20 July 2020
Resolved 20 July 2020
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 1 October 2018 Resolved
Vsl is not broadcasting dimension information (AIS Antenna Position ABCD values equals 0) and Vsl is not broadcasting static draft information
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 11 October 2018
Resolution: Verified AIS through the NAVCEN web site
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 29 June 2016 Resolved
Prove proper operation of the overspeed trip on the #1 and #2 generators.
Condition: Design Flaw
Due 22 July 2016
Resolved 29 June 2016

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.