GREEN BAY

GREEN BAY is a freight ship. The Coast Guard has recorded 97 inspections since 2016, most recently in July 2026, along with 56 deficiencies, 5 operational controls and 25 casualty investigations between 2008 and 2026.

Records from 2008 to 2026. Most recent: operational control imposed, 22 July 2026.

Built
Not recorded
Last inspected
22 July 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 22 July 2026
…with no type recorded30
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9339818
WDI3177
916754
Flag
UNITED STATES
Maury page id
psix-916754

Documentation record

Registered dimensions (L × B × D)638.8 ft × 105.8 ft × 83.1 ft
Registered tonnagegross 59,250 / net 17,775
ITC dimensions (L × B × D)638.8 ft × 105.8 ft × 83.1 ft
ITC tonnagegross 59,250 / net 17,775
BuilderTOYOHASHI SHIPBUILDING CO LTD · TOYOHASHI, JAPAN
Hull materialSteel
PropulsionDiesel Direct
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portMOBILE, AL
Trade endorsementsRegistry
DocumentationValid · issued 23 September 2025 · expires 30 September 2026
Service, as the file records itFreight Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it59250 - Convention (Subpart B), Gross Ton
17550 - Dead Weight, Ton
59700 - Displacement, Ton
17775 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 97

22 July 2026 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8444036
4 March 2026 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 8323583
23 January 2026 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8300690
4 November 2025 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 8266178
26 September 2025 Administrative Inspection · Annual Inspection · MSP Annual Oversight · MTSA/ISPS Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8241816
31 July 2025 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8199226
24 July 2025 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8200170
17 July 2025 Underwater Inspection in lieu of Drydock
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8192637
6 May 2025 In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8129783
3 May 2025 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8127959
19 March 2025 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8096517
5 March 2025 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8088667
29 January 2025 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 8071323
25 January 2025 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 8070084
23 December 2024 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 8050231
4 December 2024 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8043437
22 October 2024 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 8023225
20 October 2024 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 8021658
20 October 2024 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 8021991
10 September 2024 MSP Periodic Oversight · Periodic Inspection · MTSA/ISPS Verification · Administrative Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 7985800
19 August 2024 Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7984954
22 May 2024 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7916867
6 March 2024 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7878447
4 March 2024 Deficiency Check · Administrative Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7873796
2 November 2023 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7819542
11 September 2023 Annual Inspection · MTSA/ISPS Verification
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7874985
26 July 2023 Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7753923
18 July 2023 Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7746191
12 July 2023 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7742035
29 May 2023 Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7699818
10 May 2023 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 7685749
1 May 2023 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7685714
25 April 2023 Deficiency Check · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7675307
24 March 2023 Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7660915
18 March 2023 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 7798542
21 February 2023 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7639803
9 December 2022 Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7607781
1 December 2022 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 7602373
2 November 2022 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 7587875
11 October 2022 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 7574787
14 September 2022 Administrative Inspection · In-Service Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7559311
10 August 2022 MTSA/ISPS Verification · MSP COI Oversight · Drydock Exam · COI Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7529589
5 August 2022 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7554828
13 June 2022 Damage Survey
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 7475639
12 June 2022 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7531302
23 May 2022 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7519275
4 April 2022 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 7423931
10 March 2022 Deficiency Check · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7409732
18 January 2022 Type not recorded
No type recorded · Activities Europe · Activity 7391664
17 January 2022 Administrative Inspection
Administrative · Activities Europe · Activity 7381511
27 December 2021 Administrative Inspection
Administrative · Activities Europe · Activity 7372672
2 November 2021 MSP Annual Oversight
Type not classified · Activities Far East · USCG Oceania District (CGD-O) · Activity 7336052
21 September 2021 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7317401
21 September 2021 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7319206
25 February 2021 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7145921
25 February 2021 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7145934
25 January 2021 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7129956
10 December 2020 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7109502
4 December 2020 Administrative Inspection · Examination of Repairs
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7106170
18 November 2020 Deficiency Check · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7097655
26 October 2020 MSP Periodic Oversight · Administrative Inspection · Periodic Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7084456
1 June 2020 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6964991
28 April 2020 Underwater Inspection in lieu of Drydock
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6944819
16 March 2020 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6927217
14 March 2020 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6926476
8 March 2020 Type not recorded
No type recorded · Activities Europe · Activity 6923658
30 August 2019 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6798954
29 August 2019 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6803725
21 August 2019 Deficiency Check · Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6798457
20 August 2019 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6791437
15 August 2019 Annual Inspection · MSP Annual Oversight
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6776867
10 August 2019 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6781477
13 July 2019 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6761889
24 June 2019 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6724130
9 June 2019 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6713358
16 April 2019 Deficiency Check · In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6664379
16 April 2019 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6685851
13 April 2019 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6822729
19 February 2019 Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6628053
1 February 2019 Administrative Inspection
Administrative · Activities Europe · Activity 6618577
17 January 2019 Deficiency Check · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6611667
4 January 2019 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6610209
30 August 2018 MSP Annual Oversight · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6527556
27 August 2018 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6523918
14 June 2018 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 6443804
21 May 2018 Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6419929
17 March 2018 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6379102
16 March 2018 Administrative Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6374820
16 March 2018 Deficiency Check · MTSA/ISPS Verification · MSP Select Additional Oversight – Risk Assessment
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6375215
27 December 2017 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6363400
8 November 2017 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 6346725
23 September 2017 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 6346721
21 July 2017 MTSA/ISPS Verification · COI Inspection · Drydock Exam · MSP Select Handover Survey · Internal Structural Exam
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6211284
21 June 2017 Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6182419
3 January 2017 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6064788
15 October 2016 Administrative Inspection · Annual Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 6023513
13 January 2016 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 5820634

Deficiency record · 56

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 31 July 2025 Resolved
The machinery, boilers, and other pressure vessels; associated piping systems and fittings shall be of design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board. Vessel shall repair to the satisfaction of CG Marine Inspector. Solas (20) II-1/26.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 August 2025
Resolved 8 August 2025
Resolution: Provided Class report from ABS; generator tested w/load; all sat.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 31 July 2025 Resolved
Fire protection systems and fire-fighting systems and appliances shall be maintained ready for use. Vessel reported a leak on their fire main piping located on the starboard side boat deck. Vessel shall repair to the satisfaction of CG Marine Inspector. 74 SOLAS (20) II-2/14.1.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2025
Resolved 8 August 2025
Resolution: Provided Class report from ABS; piping cropped/renewed and tested; all sat.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 3 May 2025 Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. Vessel reported leaking in pipe from auxiliary pump that is part of the firefighting system. Vessel to provide TPO report attesting to satisfactory repair prior to departure from Jacksonville, Florida.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 May 2025
Resolution: Provided RO report.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 10 August 2022 Resolved
Before the ship leaves port and at all time during the voyage, all lifesaving appliances shall be in working order and ready for immediate use. Port side lifeboat remote control wire unspooled and became fouled during deployment due to wire twist and incorrect length. Lower STBD lifeboat, ensure proper cable payout, length and spooling. 74 SOLAS(2020) III/20.2 17c
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 September 2022
Resolution: Sat launch of STBD lifeboat with proper cable payout, length, and spooling.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 10 August 2022 Resolved
The oil record book part I shall be completed on each occasion, on a tank-to-tank basis if appropriate, whenever machinery space operations take pace. Noted discrepant ORB entries on: 14,17,20,24,26,27,29 July,10AUG. Complete internal review and correct per company and MARPOL requirement’s.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 9 September 2022
Resolution: Company completed review of logs, identified discrepancies and gave explicit instruction
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 10 August 2022 Resolved
Fire protection systems and firefighting systems and appliances shall be maintained ready for use. Vessel water mist control panel auto/manual selector switch is INOP. Manual activation functional, unable to put into automatic service. 74 SOLAS (2004) II-2 Reg 14.1 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 9 September 2022
Resolution: Switch replaced, conducted sat test of automatic activation at boiler, all sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 August 2022 Resolved
Fire protection systems and firefighting systems and appliances shall be maintained ready for use. Condemned 42 fire hoses during 100% hose pressure test. 74 SOLAS (2004) II-2 Reg 14.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 9 September 2022
Resolution: Replaced rejected hoses in kind and conducted sat pressure test.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 August 2022 Resolved
Fire protection systems and firefighting systems and appliances shall be maintained ready for use. Port side service tank quick closing valve seized. 74 SOLAS (2004) II-2 Reg 14.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 9 September 2022
Resolution: Sat operational test of quick closing valve.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 10 August 2022 Resolved
Before the ship leaves port and at all time during the voyage, all lifesaving appliances shall be in working order and ready for immediate use. STBD lifeboat neutral start interlock preventing start without heavy manual manipulation, drain line laying on top of shaft assembly, batteries not braced, P/S food storage compartment 1” of standing water, batteries not braced. 74 SOLAS (2020)III Reg 20.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 9 September 2022
Resolution: Water removed/dried, batteries braced, drain rerouted, service technician repaired and start tested, all sat.
01 - Certificates & Documentation › 013 - Documents › Unattended Machinery Spaces (UMS) Evidence
Issued 10 August 2022 Resolved
Each PSTP test instruction must specify equipment status, and apparatus necessary to perform tests. Vessel missing required testing equipment as specified in ABS approved PSTPs. 46 CFR61.40 (a)
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 October 2022
Resolution: ABS accepted as OSR; on 22OCT2022 - Properly calibrated PSTP equipment as specified in ABS-approved PSTPs was confirmed to be onboard at this time.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 10 August 2022 Resolved
The machinery shall be of a design and construction adequate for the service for which they are intended. #3 SSDG Low lube oil and high jacket water temperature alarms were inoperable, corrected. Additionally, panel indicator lights are inoperable. 74 SOLAS (2014) II-2 reg 26.1
Action required: 10 - Deficiency Rectified
Resolved 22 October 2022
Resolution: Alarms tested, all sat. Indicator light ABS OSR.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 August 2022 Resolved
Navigation bridge self-activating lifebuoys shall be capable of quick release. An unnecessary additional light was attached to buoys that would prevent free fall quick release and self activation. 74 SOLAS (2020) III reg 7.1.3
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 9 September 2022
Resolution: light removed
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 August 2022 Resolved
Terminations and joints in all conductors shall be so made as to retain the original electrical, mechanical, flame-retarding and, when necessary, fire-resisting properties of the cable. Improperly Modified common distribution board C-B spare circuit to power 03 plug cables for work connections. 74 SOLAS II-1 (2004) reg 45.5.6
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 September 2022
Resolution: ABS accepted as OSR (Finding #1036.0); cleared on 10SEP2022 - Additional plug cables were verified to be removed from distribution panel.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 10 August 2022 Resolved
The ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Port side engine room supply fan cover heavily scaled and regularly dropping chunks of scale into fan assembly. 74 SOLAS (2020) I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 9 September 2022
Resolution: Cover was descaled and painted, all sat.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 August 2022 Resolved
Exposed metal parts of electrical machines or equipment which shall be earthed.. Ground wire missing on Supply fans to P/S engine room, and CF-30R. 74 SOLAS II-1 (2004) reg 45.1.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 9 September 2022
Resolution: New grounds installed.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 17 January 2022 Resolved
EDG radiator was found leaking when conducting a routine inspection.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 17 January 2022
Resolved 25 January 2022
Resolution: Deficiency cleared by attending ABS Surveyor.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 November 2021 Resolved
The ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Observed excessive grease buildup IWO stove ventilation duct, grease weeping along exterior of duct in drop ceiling, condition presents a fire hazard. 74 SOLAS (2020) I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 December 2021
Resolved 3 December 2021
Resolution: Received sufficient documentary evidence that ventilation duct has been thoroughly cleaned.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 2 November 2021 Resolved
Instructions for on-board maintenance of life-saving appliances shall include a schedule of periodic maintenance. Immersion suits over 10 years of age shall conduct annual seam test in accordance with MSC/Circ. 1047. Amend schedule of periodic maintenance and conduct seam test in accordance with manufactures instructions. 74 SOLAS (2020)III/36.1 MSC/Circ.1047
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 2 November 2021
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 21 September 2021 Resolved
Vessel reported leak coming from main engine cyl. #4 FO pump. Reported leak rate approx 1L every 15 minutes. Vessel's equipment shall be in satisfactory condition and fit for service in which it was intended. Prior to departure from anchorage, please provide statement confirming satisfactory repairs.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 22 September 2021
Resolved 21 September 2021
Resolution: MASTER HAS SATISFACTORILY PROVIDED STATEMENT ATTESTING TO REPAIRS
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 2 November 2020 Resolved
The assignment of load lines is conditioned upon the structural efficiency and satisfactory stability of the vessel, and upon the provisions provided on the vessel for her effective protection and that of the crew. Wastage and holed that adversely affect watertight and weather-tight integrity, create down-flooding points. Aft STBD ballast water tank vent in steering gear space has pin holes in piping.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 November 2020
Resolved 3 November 2020
Resolution: Accepted as a Condition by Class (Finding No. 916.0); see Conditions of Class Opened Findings uploaded under Documents.
01 - Certificates & Documentation › 011 - Ships Certificates › Safety Management Certificate (SMC/ ISM)
Issued 30 October 2020 Resolved
The safety management system should include procedures ensuring that non-conformities, accidents and hazardous situations are reported to the company, investigated and analyzed with the objective of improving safety and pollution prevention. The company should establish procedures for the implementation of corrective action, including measures to prevent recurrence. Materiel deficiencies rendering ventilation inoperable were noted during an additional external ISM verification in April 2019; however the corrective actions were insufficient to prevent recurrence as evidenced by the following found October 2020: as identified in deficiency #2 below. Onboard records indicate that a non-SMS shipboard form is utilized for monthly inspections, which are not reported to the company in NS5. The form does not list all vent locations and does not outline the procedure for inspection. An additional internal audit is required to determine the continued lack of maintenance to the vents, the results of which to be submitted to ABS and USCG, ABS to verify the adequacy of the proposed corrective action.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2020
Resolved 30 November 2020
Resolution: Recieved acknowledgement of CAP to ABS
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 30 October 2020 Resolved
The assignment of load lines is conditioned upon the structural efficiency and satisfactory stability of the vessel, and upon the provisions provided on the vessel for her effective protection and that of the crew. Wastage and holes on the adversely affect watertight and weather-tight integrity, create down-flooding points. Inspectors found wasted electrical stuffing tube on aft part of the boat deck.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 November 2020
Resolved 4 November 2020
Resolution: Vessel cropped and renwed stuffing tube to the satisfaction of class surveyor.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 30 October 2020 Resolved
In ships having ro-ro spaces, a separation shall be provided between a closed ro-ro space and the adjacent weather deck. The separation shall be such to minimize the passage of dangerous vapours. The fwd mooring deck self closing door is wasted and had a hold back securing it in the open position.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2020
Resolved 3 November 2020
Resolution: Accepted as a Condition by Class (Finding No. 915.0); see Conditions of Class Opened Findings uploaded under Documents.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 30 October 2020 Resolved
Where a fixed fire-extinguishing system not required by Ch. II-2 of the convention is installed, it shall meet the relevant requirements of the chapter. Inspectors noted that the fire extinguishing system for the ballast water treatment house was not ready for operation due to an opened drainage valve. The vessel must make the system ready for operation.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 30 October 2020
Resolution: Vessel closed drain valve.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 26 October 2020 Resolved
The assignment of load lines is conditioned upon the structural efficiency and satisfactory stability of the vessel, and upon the provisions provided on the vessel for her effective protection and that of the crew. Wastage and holed that adversely affect watertight and weather-tight integrity, create down-flooding points. Inspectors identified the following ventilation closures that are holed, wasted, or inoperable. Air Con. fresh air, (2)laundry (p) aft, stairway (c) aft, Bow thruster (p), Steering gear rm. supply, and supply and exhaust to BWT house.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 November 2020
Resolved 3 November 2020
Resolution: Accepted as a Condition by Class (Finding No. 910.0); see Conditions of Class Opened Findings uploaded under Documents.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 26 October 2020 Resolved
he Purpose of this regulation is to provide additional safety measures in order to address the fire safety objectives of this chapter for ships fitted with vehicle, special category and ro-ro spaces. Vehicle, special category and ro-ro spaces shall be adequately ventilated. Inspectors found wastage on hub covers and or electrical junction boxes separated from the following locations; B-5S(P), BF-4S(P), DF-36(P), and DF-34R(P).
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 November 2020
Resolved 3 November 2020
Resolution: Accepted as a Condition by Class (Finding No. 912.0); see Conditions of Class Opened Findings uploaded under Documents.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Loading instrument
Issued 26 October 2020 Resolved
The structure, machinery and equipment of a cargo ship as refered to in paragraph (b)(i) shall be subject to surveys and inspections Crack was identified in the deck structure on the port side of the stern ramp.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2020
Resolved 3 November 2020
Resolution: Accepted as a Condition by Class (Finding No. 914.0); see Conditions of Class Opened Findings uploaded under Documents.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 16 April 2019 Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations. The vessel’s SMS PRO-EO-07 “Planned maintains program” states that the generators are essential machinery and unplanned shutdown or overdue maintenance must be documented by a verbal risk assessment between the company and the crew. No risk assessment was conducted or documented on board the vessel. The No.1 SSDG tripped offline in an unplanned shutdown and loss of propulsion. Records indicate that several maintenance items were past due by 900 to 14000 hours. An ISM SMC external audit is required.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 16 April 2019
Resolved 16 April 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 April 2019 Resolved
Machinery and associated piping service shall be designed and constructed adequate for the service in which they are intended. A soft patch was identified on the air supply to the MDE, No.5 cylinder fuel injector. Once removed air continuously leaked out. Make permanent repairs to the air line to prevent leakage.
Action required: 17 - Rectify deficiencies prior to departure
Due 17 April 2019
Resolved 16 April 2019
01 - Certificates & Documentation › 013 - Documents › Unattended Machinery Spaces (UMS) Evidence
Issued 16 April 2019 Resolved
Provided a fully functioning planned maintenance program to meet the requirements for the vessel's minimally attended machinery plant. The vessel had ABS' NS Enterprise however it omitted generator maintenance which was being tracked on a separate spreadsheet. The generator that failed while entering port had 20 overdue items ranging from 60 to 14,988 hours overdue.
Action required: 705 - Other - as specified
Due 16 May 2019
Resolved 12 June 2019
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 16 April 2019 Resolved
Cargo ships of 4000 GT and upwards must have at least two independent fire pumps in addition to the emergency pump and be ready for immediate service. One fire pump was disassembled and the other was cross connected to an auxiliary salt water cooling system, providing emergency cooling.
Action required: 17 - Rectify deficiencies prior to departure
Due 17 April 2019
Resolved 17 April 2019
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 16 April 2019 Resolved
SOLAS(14) II-2/7.3.2 - Provide records that the fixed fire detection system has been tested by means of equipment producing hot air or smoke.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2019
Resolved 2 July 2019
Engineering › Diesel Engine (propulsion-direct drive) › Injector (fuel injection)
Issued 17 March 2018 Resolved
MDE fuel leak. Replace gasket, obtain ABS class report.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 March 2018
Resolved 17 March 2018
Resolution: Received class report with repair and testing procedure. All sat.
Fire Fighting › Ventilation Systems › Operating Controls
Issued 16 March 2018 Resolved
Closure controls for cargo deck vent ducts heavily corroded and missing handles. Prepare replacement plan for all closure controls to the satisfaction of Coast Guard. 74 SOLAS (14) II-2/5.2.1.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 April 2018
Resolved 14 May 2018
Resolution: Repair plan in place and a P.O. issued for replacement parts.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 16 March 2018 Resolved
Lifejacket and immersion suit stowage on boat deck Frame 0 severely wasted. Replace stowage container. 74 SOLAS (14) III/20.2
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 April 2018
Resolved 21 May 2018
Resolution: Stowage container repaired.
Fire Fighting › Miscellaneous Items › Insulation (Penetration of Oil/Oil Vapors)
Issued 16 March 2018 Resolved
Lagging surrounding fuel oil heater and fuel oil purifier is soaked with oil. Replace lagging to reduce hazard and minimize danger. 74 SOLAS (04) II-1/26.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 April 2018
Resolved 14 May 2018
Resolution: New lagging has been installed.
Electrical › Lighting (service) › Lighting Fixture
Issued 16 March 2018 Resolved
Within engine room, multiple wires surrounding light fixtures were joined via wire nuts not within junction boxes. Ensure all conductors are properly installed. 74 SOLAS (04) II-1 45.5.6.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 April 2018
Resolved 14 May 2018
Resolution: Light fixtures have been propely repaired.
Fire Fighting › Ventilation Systems › Ducts
Issued 16 March 2018 Resolved
#3 Generator exhaust duct has excessive vibration which will eventually cause leakage. Reduce vibrations. 74 SOLAS (04) II-1/35
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 April 2018
Resolved 14 May 2018
Resolution: Mount for exhaust duck repaired.
Engineering › Fuel Oil Service System › Pump
Issued 6 August 2017 Resolved
#1 F/O supply pum inop.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 8 August 2017
Engineering › Compressed Air System (start air) › Compressor
Issued 6 August 2017 Resolved
#2 Air Compressor inop.
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Resolved 9 August 2017
Resolution: Confirmed via email from CHENG through master with supporting photo documentation and explanation of repairs
Fire Fighting › Means of Escape › Doorways
Issued 6 August 2017 Resolved
Elevator door failure to close properly
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 8 August 2017
Resolution: Door cleaned and lubricated, found in proper functioning order upon follow up.
Engineering › Freshwater System (jacketwater cooling) › Pump
Issued 6 August 2017 Resolved
F/W cooling pump inop.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 8 August 2017
Resolution: Tested sat upon return visit by MI
Engineering › Sea-water System (primary cooling) › Pump
Issued 6 August 2017 Resolved
S/W cooling pumps inop
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Resolved 8 August 2017
Resolution: Pump tested sat by MI during return visit
Fire Fighting › Fixed Fire Detection System › Flame Detectors
Issued 6 August 2017 Resolved
Fire detector above boiler not working properly
Action required: 60 - Rectify deficiencies prior to movement
Resolved 8 August 2017
Resolution: Tested by CHENG and MI during return visit IAW manufacturer's instructions
Operations/Management › Pollution › Retention of Oily Mixture
Issued 6 August 2017 Resolved
Oily bilge in "snake pit" area
Action required: 60 - Rectify deficiencies prior to movement
Due 10 August 2017
Resolved 8 August 2017
Resolution: Oil cleaned/removed upon return visit as seen by MI
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 6 August 2017 Resolved
Matting missing in front of 220/440 panels throughout E/R and steering gear space
Action required: 705 - Other - as specified
Due 20 August 2017
Resolved 8 August 2017
Resolution: Matting added in front of all panels
Operations/Management › Pollution › Retention of Oily Mixture
Issued 6 August 2017 Resolved
Clean up oil in F/O pump containment area.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 August 2017
Resolved 8 August 2017
Resolution: Oil removed and area clean.
Operations/Management › Pollution › Removal Methods/Procedures
Issued 6 August 2017 Resolved
Remove excess oil in settling tank containment
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 August 2017
Resolved 8 August 2017
Resolution: Oil removed/cleaned from containment area.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 6 August 2017 Resolved
3 detectors found inop on cargo deck 5
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 8 August 2017
Resolution: Sensors tested during return visit by MI
Documentation › Markings/Placards › Warning Signs
Issued 6 August 2017 Resolved
"E" lighting not labled with Red "E"
Condition: Improper Installation
Due 20 August 2017
Resolved 16 March 2018
Resolution: All "E" lighting inspected labled with Red "E"
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 6 August 2017 Resolved
F/W manhole cover not installed properly
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 8 August 2017
Resolution: Hatch needed to be properly fitted, verified secure by MI during revisit.
Engineering › Engine Controls (Electric/Electronic) › Software
Issued 15 October 2016 Resolved
The existing PSTP for items 9.4 and 9.5 do not adequately describe each step required to complete the procedure, ie.e the procedures list a step that inadvertantly secures the engine while installing the test equipment. This equipment should be installed prior to starting the engine for the test. Address this issue & provide updated PSTP to USCG MSC or ACS per NVIC 01-13, Ch. 1, Enclosure (2)
Action required: 705 - Other - as specified
Due 14 April 2017
Resolved 21 June 2017
Resolution: PSTP approval verified with ABS.
Engineering › Engine Controls (Electric/Electronic) › Software
Issued 15 October 2016 Resolved
The existing PSTP for item 9.15 requires a step that is potentially harmful to sensitive electronic equipment. The Reverse Power Relay Test Procedure brought the cycles down to below 58 Hertz. Address this issue and provide updated PSTP to USCG MSC or ACS per NVIC 01-13, Ch. 1, Enclosure (2)
Action required: 705 - Other - as specified
Due 14 April 2017
Resolved 21 June 2017
Resolution: PSTP approval verified with ABS.
Pollution Prevention/Response › Response Equipment › Non-sparking Hand Scoops/Shovels/Buckets
Issued 15 October 2016 Resolved
SOPEP equipment does not have non-sparking shovels. Replace shovels with proper non-sparking equipment.
Action required: 705 - Other - as specified
Due 15 November 2016
Resolved 15 November 2016
Resolution: Corrected
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 15 October 2016 Resolved
Lifebuoy self-igniting light did not have the proper batteries, i.e. springs versus studs, to ensure proper electrical connection. Replace all batteries with proper batteries on all affected lights.
Action required: 705 - Other - as specified
Due 15 November 2016
Resolved 15 November 2016
Resolution: Corrected
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 15 October 2016 Resolved
Fire screen door to wheelhouse must be self-closing. Ensure A-0 fire screen door to wheelhouse is adjusted to be self-closing.
Action required: 705 - Other - as specified
Due 15 November 2016
Resolved 15 November 2016
Resolution: Corrected

Casualty record · 25

13 November 2008Routine · role: Involved in a Marine Casualty · activity 3444012
23 September 2017Routine · role: Involved in a Marine Casualty · activity 6346721
8 November 2017Routine · role: Involved in a Marine Casualty · activity 6346725
17 March 2018Routine · role: Involved in a Marine Casualty · activity 6379102
4 January 2019Routine · role: Involved in a Marine Casualty · 1 dead · activity 6610209
13 April 2019Routine · role: Involved in a Marine Casualty · activity 6822729
16 April 2019Routine · role: Involved in a Marine Casualty · activity 6685851
9 June 2019Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6713358
24 June 2019Routine · role: Involved in a Marine Casualty · activity 6724130
13 July 2019Routine · role: Involved in a Marine Casualty · activity 6761889
10 August 2019Routine · role: Involved in a Marine Casualty · activity 6781477
20 August 2019Routine · role: Involved in a Marine Casualty · activity 6791437
29 August 2019Routine · role: Involved in a Marine Casualty · activity 6803725
10 December 2020Routine · role: Involved in a Marine Casualty · activity 7109502
21 September 2021Routine · role: Involved in a Marine Casualty · activity 7319206
18 January 2022Routine · role: Involved in a Marine Casualty · activity 7391664
23 May 2022Routine · role: Involved in a Marine Casualty · activity 7519275
12 June 2022Routine · role: Involved in a Marine Casualty · activity 7531302
1 May 2023Routine · role: Involved in a Marine Casualty · activity 7685714
12 July 2023Routine · role: Involved in a Marine Casualty · activity 7742035
20 October 2024Routine · role: Involved in a Marine Casualty · activity 8021658
25 January 2025Routine · role: Involved in a Marine Casualty · activity 8070084
4 November 2025Routine · role: Involved in a Marine Casualty · activity 8266178
23 January 2026Routine · role: Involved in a Marine Casualty · activity 8300690
4 March 2026Routine · role: Involved in a Marine Casualty · activity 8323583
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.