Records from 2012 to 2026. Most recent: inspection, 24 July 2026.
Inspection history · 50
24 July 2026
Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8438170
16 July 2026
Examination of Repairs · Vessel Attendance · Damage Survey
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8440290
4 March 2026
Vessel Attendance · Drydock Exam · Internal Structural Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8319634
20 June 2025
DAPI Audit · MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8141625
26 April 2025
Administrative Inspection · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8120596
26 April 2025
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8121804
17 April 2025
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8113132
23 July 2024
Annual Inspection · DAPI Audit · MTSA Verification
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7960035
28 May 2024
Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7921720
8 April 2024
Administrative Inspection · Deficiency Check · Damage Survey
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7894875
2 March 2024
Damage Survey · Administrative Inspection · Examination of Repairs
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7873221
2 March 2024
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7874298
17 January 2024
Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7850630
14 November 2023
In-Service Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7828034
7 July 2023
In-Service Inspection · Deficiency Check
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7738328
6 July 2023
Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7738349
9 May 2023
Deficiency Check · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7684574
26 June 2022
Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7488154
11 May 2022
Deficiency Check · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7452336
20 January 2022
Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7382565
12 May 2021
Annual Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7195532
16 March 2021
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7157874
7 March 2021
Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7152635
7 March 2021
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7155216
10 November 2020
Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7089482
28 July 2020
Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7001558
15 April 2020
Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6936387
7 January 2020
Drydock Exam · Internal Structural Exam · Administrative Inspection · Examination of Repairs
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6884250
31 October 2019
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6848761
26 October 2019
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6854188
3 October 2019
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6827459
1 October 2019
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6825336
26 September 2019
In-Service Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6822751
26 August 2019
Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6802826
9 May 2019
DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6680882
10 January 2019
Examination of Repairs
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6608339
30 October 2018
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6573477
8 August 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6504825
5 August 2018
Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6517829
23 April 2018
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6399319
21 April 2018
Damage Survey
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6397473
21 April 2018
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6397512
5 April 2018
Annual Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6383313
8 March 2018
Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6370697
11 December 2017
Hull Examination · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6322000
17 October 2017
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6287019
4 May 2017
DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6143749
19 May 2016
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6049267
10 May 2016
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5878755
29 January 2016
Hull Examination · Drydock Exam · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5803390
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 17 July 2026
Resolved
Rails or equivalent protection must be installed near the periphery of all decks of a vessel accessible to passengers or crew. The deck rail on the aft embarkation deck was damaged due to an allision with a pier. Affect proper repairs to rail prior to passengers accessing the deck.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 July 2026
Resolution: Temporary repairs were made and operator submitted an appropriate plan for permaneny repairs
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 17 July 2026
Resolved
Each window, port hole, and its means of attachment to the hull or deck house, must be capable of with standing the maximum load from wave and wind conditions expected due to its location on the vessel and the authorized route of the vessel. Two windows on the staeboard side in the dining room were shattered. Repair windows to the satisfaction of the attending marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 July 2026
Resolution: Temporary repairs were made and operator submitted an appropriate plan for permaneny repairs
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 July 2026
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection. Vessel suffered damage to superstructure during a marine casualty. Affect repairs to the satifcation of the attending marine inspection prior to next dry dock credit.
Action required: 705 - Other - as specified
Resolved 28 July 2026
Resolution: Converted to Worklist item.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 April 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to provide services necessary for safety under normal and emergency conditions. Starboard side generator lost power due to low oil pressure from an oil leak in the pump. Centerline generator was found to be smoking on previous inspection.
Provide third party technical report and conduct full operational test to the satisfaction of the attending marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 April 2025
Resolution: MI's inspected operation of the starboard side engine and verified installation of new fuel oil pump.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 17 April 2025
Resolved
Electrical equipment installed and maintained on a vessel must provide services necessary for safety under normal and emergency situations.
Vessel sustained a loss of their center generator which is 1 of 3 main generators. Vessel is required to only have 2 generator sets. Spoke with the Port Engineer and the Master to determine that the gen-set portion of the generator needs to be replaced. The watch stander saw smoke coming from the generator-set and he secured it while the generator was in parallel and this singled up the machine plant to one generator. This is not a reportable casualty considering they have 3 total main generators and they did not lose power or maneuverability. Vessel is to provide tech report and have CG come onboard and clear the CG-835V within 30 days of repair.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 May 2025
Resolved 1 May 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 April 2024
Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. After new shaft installation and alignment, STBD engine transmission cooler improperly aligned with fixed piping resulting in cooler required to be temporarily ratchet strapped in place to maintain connection.
46 CFR 119.100
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2024
Resolved 28 May 2024
Resolution: Deficiency rectified.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 July 2023
Resolved
Vessel had to shut down stbd engine due to high crankcase pressure.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 July 2023
Resolved 9 July 2023
Resolution: Repairs made to engine. Satisfactory load tests were perfomed.
07 - Fire Safety › N/A - No Subsystem › Fire patrol
Issued 9 May 2023
Resolved
07107 - Vessels described by 46 CFR 114.110 (f) must submit plans to the cognizant OCMI for the installation and use of monitoring device(s) to ensure the wakefulness of the watchmen required by paragraph (a) of this section. The monitoring device(s) must ensure the wakefulness of the crew in the event that the watchman required in paragraph (a) of this section is unresponsive.
ACL’s plan to comply with the SPV Fire Safety IFR requirements for monitoring devices as required by this regulation, entitled “Fire Watchkeeping Plan, Revision 1”, dated 30 January 2023, calls for the night watchman to carry a Motorola handheld radio with Lone Worker-Emergency function programmed, which will trigger an alarm if not keyed by the night watchman every <15 minutes.
The only Motorola handheld radio with the Lone Worker-Emergency function available onboard has been inoperable for at least the past two weeks.
46 CFR 122.410(b)
705c: correct prior to 5/12/2023
Action required: 705 - Other - as specified
Due 12 May 2023
Resolved 12 May 2023
Resolution: A properly programmed and functioning Motorola radio with the Lone-Worker functionality was provided onboard. The attending MIs observed an operational test of the 15 minute pre-alarm and alarm sequence.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 9 May 2023
Resolved
07105 - Doors in A-Class fire control boundaries must meet the following additional requirements: A door must be of the self-closing type, capable of closing against a 3.5
degree list of the vessel. The following A class fire doors did not fully close and latch when tested: stairwell from deck 1 leading down to crew quarters, entry to dining room, port stabilizer room, and entry to laundry compartment.
46 CFR 116.435(c)(1) & (c)(6)
705c: correct prior to 5/12/2023
Update 12May23: the deck 1 stairwell and entry to dining room doors have been corrected to the satisfaction of the attending MIs. Partial repairs have been made to the laundry room and port stabilizer doors, with full repairs to follow. The due date for full repairs of these two remaining doors has been extended to 6/9/23. The vessel may carry passengers between now and 6/9/23.
Update 22May23: laundry room door has been corrected, only the port stabilizer door repairs pend to date.
Action required: 705 - Other - as specified
Due 12 May 2023
Resolved 25 May 2023
Resolution: As of today's date, satisfactory repairs to all listed doors have been carried out and confirmed by either in-person attendance of CG MIs or submission of objective evidence to Sector Maryland-NCR by vessel reps.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 9 May 2023
Resolved
07115 - A duct penetrating an A-Class fire control boundary and opening into a space formed by that boundary must be equipped with a fire damper.
Fire dampers in the engine room did not close when activated.
46 CFR 116.610(f)(4)
705c: correct prior to 5/12/2023
Action required: 705 - Other - as specified
Due 12 May 2023
Resolved 12 May 2023
Resolution: Both fire dampers for the main machinery space were operationally tested via the remote actuation to the satisfaction of the attending Marine Inspectors.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 9 May 2023
Resolved
04103 - Each vessel must have adequate emergency lighting fitted along the line of escape to the main deck from all passenger and crew accommodation spaces located below the main deck.
The emergency lights were inoperable in the dry food stores and forward passageway.
46 CFR 122.432
705c: correct by 5/12/2023
Action required: 705 - Other - as specified
Due 12 May 2023
Resolved 12 May 2023
Resolution: Both e-lights were replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 May 2023
Resolved
11117 - At least one ring buoy must be fitted with a floating waterlight. Each floating waterlight must be approved in accordance with 161.010.
The waterlight for the ring lifebuoy is a model ACR SM-3. The relevant CG type approval certificate, 161.010/30/0, states that it is to be “powered by two removable AA lithium batteries to be replaced in
accordance with the manufacturer's instructions. Not approved for use with alkaline batteries." The manufacturer’s instructions call for 2 AA lithium L91 batteries, to be replaced on an annual basis. At least one ring buoy must be fitted with a floating waterlight.
The batteries currently in the waterlight onboard appear to be of the alkaline type.
46 CFR 117.70(d)
705c: correct by 5/12/2023
Action required: 705 - Other - as specified
Due 12 May 2023
Resolved 12 May 2023
Resolution: The waterlight batteries were replaced with new batteries of the proper type.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 9 May 2023
Resolved
11108 - Every vessel equipped with an inflatable survival craft must have approved placards or other cards containing instructions for launching and inflating inflatable survival craft for the information of persons on board posted in conspicuous places by each inflatable survival craft.
There are no instruction placards posted by each IBA.
46 CFR 122.518(a)
705c: correct by 5/12/2023
Action required: 705 - Other - as specified
Due 12 May 2023
Resolved 12 May 2023
Resolution: A temporary placard was provided on the stack near each IBA launching station. The vessel rep provided proof of ordering the full placards from the manufacturer (Viking) to be delivered and installed onboard in due course.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 9 May 2023
Resolved
11199 - Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Child and adult lifejackets are not segregated currently.
46 CFR 117.78(a)(5)
705c: correct by 5/12/2023
Action required: 705 - Other - as specified
Due 12 May 2023
Resolved 12 May 2023
Resolution: A divider was installed to separate the child and adult lifejackets to the satisfaction of the attending Marine Inspectors.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 9 May 2023
Resolved
07105 - Doors in A-Class fire control boundaries must meet the following additional requirements: A-Class bulkheads or decks must be constructed that, if subjected to the standard fire test, they are capable of preventing the passage of smoke and flame for 1 hour. The boundaries surrounding the port and starboard stabilizer rooms are listed as A-60 on the current version of the fire control plan. On both doors there is a gap, large enough for a pen to fit in, between the door frame and the bulkhead so that it does not seat flush. The stabilizers may not be used until the doors have been fixed.
46 CFR 116.435(c)(1)
46 CFR 116.415(a)(2)(i)
50c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 June 2023
Resolved 25 May 2023
Resolution: Vessel rep provided pictures and videos showing how additional bolts were added to pull the door frame against the bulkhead, and intumescent STI fire sealant was added to seal any remaining air gap.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 May 2023
Resolved
13199 - Unless it otherwise complies with this subpart, each self-propelled vessel must be provided with a main steering gear and an auxiliary steering gear. These gear must be arranged so that: transfer from the main to the auxiliary can be effected quickly.
The port side cleat for the emergency steering was broken.
46 CFR 119.600
46 CFR 58.25-5(b)(2)
50c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 June 2023
Resolved 19 May 2023
Resolution: Received photographic evidence of the fixed cleat.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 9 May 2023
Resolved
11135 - Each EPIRB, other than an EPIRB in an inflatable liferaft, must be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative.
The vessel had no record of monthly EPIRB tests. The EPIRB was tested and the test logged while marine inspectors were on board.
46 CFR 122.728(a)
10c
Action required: 10 - Deficiency Rectified
Due 9 May 2023
Resolved 9 May 2023
Resolution: The EPIRB was tested and logged while Marine Inspectors were on board.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 11 May 2022
Resolved
Piping, including valves, pipe fittings and flanges, conveying vapor, gas, or liquid, the temperature of which exceeds 65.5°C (150 °F), must be insulated where necessary to prevent injuries. Exhaust lagging on port engine and middle generator missing or not fully covering exhaust piping.
46CFR116.970
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2022
Resolved 26 May 2022
Resolution: Confirmed with vessel rep through emailed photos that lagging was satisfactorily installed around exhaust.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 May 2022
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other
persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Wasted insulation and deadend wires observed on battery and battery charging cables.
46CFR120.200(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 June 2022
Resolved 26 May 2022
Resolution: Wiring satisfactorily addressed and verified via emailed picture.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 May 2022
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from
adult life jackets so the child size life jackets are not mistaken for adult life jackets. Child and adult life jackets are stowed together without adequate separation on upper weather deck.
46CFR117.78(a)(5)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 June 2022
Resolved 26 May 2022
Resolution: Adult and child life jackets separated with spacer.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 11 May 2022
Resolved
Each life jacket, immersion suit, and ring life buoy must be marked in clearly legible block capital letters
with the vessel’s name. Vessel name has not been updated on life jackets and ring life buoys.
46CFR122.604(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 June 2022
Resolved 26 May 2022
Resolution: Confirmed through vessel rep the proper marking of life jackets and life ring buoys.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 11 May 2022
Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with §80.59 once every five years. If the ship passes the inspection, the technician will issue a Communications Act Safety Radiotelephony Certificate.
Vessel did not have a current Communications Act Safety Radiotelephony Certificate.
46CFR121.502
47CFR80.903
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 June 2022
Resolved 26 May 2022
Resolution: FCC Radiotelephony Certificate issued 5/11/2022 to 5/11/2027.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 11 May 2022
Resolved
The Bridge-to-Bridge Act and the regulations of this part apply to [every power-driven vessel of 20 meters or over in length while navigating] in the navigable waters of the United States. Each vessel must carry a certificate with a valid endorsement while subject to the Bridge-to-Bridge Act. Vessel did not have a current Vessel Bridge-to-Bridge Radiotelephony Certificate.
46CFR121.502
47CFR80.1001
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 June 2022
Resolved 26 May 2022
Resolution: FCC Bridge-To-Bridge Radiotelephony Certificate issued from 5/11/2022 to 5/11/2027.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 May 2021
Resolved
Where the general emergency alarm signal cannot be heard over the background noise, there must be a red-flashing light or rotating beacon, in addition to the general emergency alarm signal. Visual indicator was inoperable at time of inspection.
46 CFR 120.550(b)
46 CFR 113.25-10(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2021
Resolved 26 May 2021
Resolution: Received satisphactory photographic evidence from vessel representative [name withheld] confirming proper operation of visual indicator.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 May 2021
Resolved
All audible and visual alarms must be audible and visible throughout the spaces they are intended to alert. Visual and audible alarms in engine room were inoperable at time of inspection.
46 CFR 118.400(c)
46 CFR 76.27-20(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2021
Resolved 26 May 2021
Resolution: Received satisfactory photographic/video evidence from vessel rep [name withheld] confirming proper operation of visual/audible alarms in engine room.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 12 May 2021
Resolved
Deck rails must be designed and constructed to withstand a point load of 91 kilograms (200 pounds) applied at any point in any direction. Railing at vessel's "aft swim platform" was not of suitable strength to withstand required load.
46 CFR 116.900(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2021
Resolved 26 May 2021
Resolution: Received satisfactory photographic evidence from vessel rep [name withheld] confirming proper railing installation at vessel's "aft swim platform."
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 May 2021
Resolved
The general construction of the vessel must be such as to minimize fire hazards insofar as it is reasonable and practicable. Overheads in electronics locker adjacent to second deck "Powder Room" and stores locker forward second deck ship's office were missing required structural fire protection at time of inspection.
46 CFR 116.405(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2021
Resolved 26 May 2021
Resolution: Received satisfactory photographic evidence from vessel rep [name withheld] confirming structural fire protection repaired in locations noted.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 12 May 2021
Resolved
Suitable means, such as a manual damper, automatic damper, or vent cover, must be provided in an accessible location outside the space served by the ventilation duct for shutting off the passage of air through the ventilation duct in the event of fire. Dampers on vessel's bow leading to crew laundry did not fully close at time of inspection.
46 CFR 116.610(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2021
Resolved 26 May 2021
Resolution: Received satisfactory photographic evidence from vessel rep [name withheld] confirming proper operation of fire dampers leading to crew laundry.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 12 May 2021
Resolved
Each door, hatch, or scuttle, used as a means of escape, must be capable of being opened by one person, from either side, in both light and dark conditions. Emergency escape from passageway adjacent forward crew laundry was unable to be opened from interior by one person.
46 CFR 116.500(i)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2021
Resolved 26 May 2021
Resolution: Received satisfactory photographic/video evidence from vessel rep [name withheld] confirming emergency escape operating properly.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 March 2021
Resolved
The installed ring life buoys were found unserviceable. Vessel is required three buoys, the outer coverings and grab lines were sun damaged on all of the installed buoys.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 17 March 2021
Resolved 17 March 2021
Resolution: VSL has replaced all ring life buoys and lifelines.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 March 2021
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery including operation of the main propulsion machinery both ahead and astern. Vessel's port main propulsion engine was found to be not operational after blown piston rods during a sea trial. Vessel shall make repairs and notify the Coast Guard prior to getting underway with passengers.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 March 2021
Resolved 12 March 2021
Resolution: Port MDE was replaced.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 7 March 2021
Resolved
Table 118.500(a) of this section indicates the minimum required number and type of extinguisher for each space listed. Vessel's port main engine suffered piston rod failures resulting in a fire on the engine. Vessel shall replace the portable fire extinguishers used to extinguish the fire.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 March 2021
Resolved 12 March 2021
Resolution: Fire extinguisher was serviced by third party and placed back into service.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 28 July 2020
Resolved
No crew to conduct fire drill. Conduct fire drill prior to carrying passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 August 2020
Resolved 10 November 2020
Resolution: Witnessed satisfactory man overboard and fire drills.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 28 July 2020
Resolved
No crew available to conduct MOB drill. Conduct MOB drill prior to carrying passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 August 2020
Resolved 10 November 2020
Resolution: Witnesses satisfactory MOB drill.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 28 July 2020
Resolved
No current evidence of crew drug testing.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2020
Resolved 31 July 2020
Resolution: Provided evidence of current enrollment in drug testing program
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 28 July 2020
Resolved
Alcohol test strips expired
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2020
Resolved 31 July 2020
Resolution: Test strips onboard
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 July 2020
Resolved
Non-marine power strip found in ship's office.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2020
Resolved 31 July 2020
Resolution: Power strip removed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 July 2020
Resolved
Bilge suction not operable in void #5
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2020
Resolved 31 July 2020
Resolution: Bilge suction operational
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 28 July 2020
Resolved
Replace cover on emergency light in void space #5
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2020
Resolved 31 July 2020
Resolution: Light cover put in place
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 July 2020
Resolved
Provide CO2 placard where CO2 siren is located.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2020
Resolved 18 August 2020
Resolution: Properly marked
08 - Alarms › N/A - No Subsystem › General alarm
Issued 28 July 2020
Resolved
General alarm placard is missing in laundry space.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2020
Resolved 18 August 2020
Resolution: Properly marked
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 November 2019
Resolved
33CFR160.212(a)(4)(ii): Failure to provide notice of arrival at least 24 hours before entering the port or place of destination when embarking on a voyage of less than 96 hours.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 12 November 2019
Resolution: LOW issued to Captain and accepted on 26OCT2019
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 1 October 2019
Resolved
Prove proper operation of emergency escape release mechanism after permanent repairs have been made.
Please notify our office when repairs are complete. This requirement to be corrected by 31October2019.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2019
Resolved 31 October 2019
Resolution: cable renewed as original. Tested satisfactory.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 8 August 2018
Resolved
Vsl is broadcasting: : Invalid IMO #.
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 September 2018
Resolved 30 October 2018
Resolution: Received email confirmation that vessel is broadcasting appropriate IMO number.
Construction/Loadline › Hull › Side Shell
Issued 21 April 2018
Resolved
Make permanent repairs to the STBD Side dining room and engine room IWO damaged area, to the satisfaction of the attending Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 23 April 2018
Resolved 24 April 2018
Resolution: Damage limited to 03 port lights, all three replaced and found satisfactory.
Communications › Audible Communications › Bell
Issued 5 April 2018
Resolved
Provide ship's bell
Action required: 705 - Other - as specified
Due 12 April 2018
Resolved 11 April 2018
Resolution: Vessel rep provided photo showing the ship’s bell is properly mounted onboard.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 5 April 2018
Resolved
Provide photoluminescent tape indicating engine room escape routes.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2018
Resolved 19 April 2018
Resolution: Emergency exit sign properly posted and visible in the dark.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 5 April 2018
Resolved
Fix missing insulation from various locations in engine room, galley stores, and laundry room aft bulkhead
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2018
Resolved 19 April 2018
Resolution: All insulation properly installed.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 5 April 2018
Resolved
Update emergency instructions to be ship-specific.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2018
Resolved 19 April 2018
Resolution: Emergency instructions are now accurate for the vessel.
Stability › Weathertight Integrity › General
Issued 5 April 2018
Resolved
Fix 03 damaged window frames on port side.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 May 2018
Resolved 19 April 2018
Resolution: One frame was replaced and two were satisfactorily repaired and sealed.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 5 April 2018
Resolved
Secure outlets below panelboards on fwd engine room bulkhead, stbd side.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2018
Resolved 19 April 2018
Resolution: Outlet box is now secured.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 5 April 2018
Resolved
Prove proper operation of battery-powered emergency light in galley stores.
Action required: 10 - Deficiency Rectified
Resolved 5 April 2018
Resolution: Battery was replaced and proper operation was demonstrated.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 6 February 2018
Resolved
The ducts in the engine room are not fitted with automatic fire dampers. Ducts serving machinery spaces must be fitted with automatic fire dampers. Rectify prior to carrying passengers in 2019.
Action required: 705 - Other - as specified
Due 1 April 2019
Resolved 5 April 2018
Resolution: Demonstrated proper operation of new engine room automatic fire damper system - heat gun applied to heat detector.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 11 December 2017
Resolved
The fire dampers in the engine room are not fitted with indicators showing whether the dampers are open or closed. Rectify prior to carrying passengers in 2019.
Action required: 705 - Other - as specified
Due 1 April 2019
Resolved 8 March 2018
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 11 December 2017
Resolved
The fire dampers in the engine room are not marked with red letters of at least 12.7 mm (0.5 in) in height stating "VENTILATION FIRE DAMPER".
Action required: 705 - Other - as specified
Due 5 March 2018
Resolved 8 March 2018
Electrical › Electric Supply System (service) › Battery Charger
Issued 17 October 2017
Resolved
Battery chargers are over 2KW and the vessel does not comply with the requirements of a large battery installation.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 23 October 2017
Resolved 23 October 2017
Resolution: Recieved photo from owner with battery chargers less than 2KW. Photo is attached to this activity.
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 10 May 2016
Resolved
Replace broken heat detector in galley.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 17 May 2016
Resolved 19 May 2016
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 10 May 2016
Resolved
Provide local indication of rudder angle in steering gear room.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 10 June 2016
Resolved 19 May 2016