The 2 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Share this recordDownload vessel cardDownload QRMaury, US Coast Guard vessel record for DAN EAGLE, retrieved 18 September 2026. mauryrecords.com/v/psix-916907.html
Documentation record
Tonnage as PSIX records it12578 - Regulatory (Subpart C or D), Net Ton 55768 - Displacement, Ton 44700 - Dead Weight, Ton 28448 - Regulatory (Subpart C or D), Gross Ton 28448 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 2
21 April 2009Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3457280
25 November 2008ISPS II Exam · PII Safety Exam · MARPOL Annex I Examination · MARPOL Annex V Examination · Ballast Water Examination · COC-TVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3369016
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 25 November 2008Resolved
Inert Gas System failed to produce 5% oxygen through system, thus creating tank atmospheres above 8%. Prior to conducting Cargo Operations, make effective repairs to IGG and ensure O2 is being produced at less than 5%, and that all cargo tanks are below 8% to the satisfaction of the attending Class Surveyor.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 November 2008
Resolution: Rcvd fax copy from Class Surveyor stating repairs were completed on IGG, and that all cargo tanks were below 8% oxygen. Deficiecny cleared
Engineering › Lubricating Oil Storage/Transfer System › Piping
Issued 25 November 2008Resolved
The mechanical seal on the #1 M/E Fuel Oil Circ. Pump is leaking, causing oil to leak onto the deck, creating an unsafe condition. Replace seal and properly dispose of excess oil to the satisfaction of attending Class Surveyor.
Action required: 705 - Other - as specified
Due 25 December 2008
Resolved 25 November 2008
Resolution: Mechanical shaft seal has been changed and area has been thoroughly cleaned. Def cleared
Excessive accumulation of oil on deck in vicinity of Inert Gas Diesel Generator in Oil Purifier Room. Clean up space to the satisfaction of attending Class Surveyor.
Action required: 705 - Other - as specified
Due 25 December 2008
Resolved 25 November 2008
Resolution: Rcvd fax from Class Surveyor attesting to proper clean-up of space. Deficiency cleared
Ship is missing Oil Discharge Pollution placard as required by 33CFR155.450 in vicinity of overboard discharge for OWS. Ensure placard is posted to the satisfaction of the attending Class Surveyor.
Action required: 705 - Other - as specified
Due 25 December 2008
Resolved 25 November 2008
Resolution: Rcvd fax from Class Surveyor stating that placard has been properly posted. Deficiency cleared.
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 25 November 2008Resolved
Due to an alteration in the Engine Control Room with an additional switchboard being placed in ECR, structural fire protection has been comprised to the lack of insulation on the backside of the switchboard. Ensure proper insulation is installed to the satisfaction of the attending Class Surveyor.
Action required: 705 - Other - as specified
Due 25 December 2008
Resolved 25 November 2008
Resolution: DNV attested to satisfactory repair of affected area. Defs cleared.