MAURY USCG vessel records
← All vessels

ATLANTIC LOYALTY

ATLANTIC LOYALTY is a 2007 tank ship. The Coast Guard has recorded 4 inspections since 2017, most recently in March 2023, along with 3 deficiencies.

Records from 2017 to 2023. Most recent: inspection, 11 March 2023.

Built
2007
Last inspected
11 March 2023
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 11 March 2023
Operational controls None recorded without a removal date
Years with a record 3 calendar years (2017–2023)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9312509
7VA5599
917226
Flag
LIBERIA
Maury page id
psix-917226

Documentation record

Tonnage as PSIX records it307284 - Dead Weight, Ton
351284 - Displacement, Ton
159987 - Convention (Subpart B), Gross Ton
159987 - Regulatory (Subpart C or D), Gross Ton
103933 - Convention (Subpart B), Net Ton
103933 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 4

11 March 2023 Deficiency Check · COC-TVE Renew · PSC B
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7643396
23 May 2020 PSC B · COC-TVE Renew · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6952438
13 May 2020 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6952433
7 August 2017 COC-TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6219002

Deficiency record · 3

11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 11 March 2023 Resolved
THE ENGINE SHALL BE CAPABLE OF OPERATING FO NOT LESS THAN 5 MINUTES AFTER STARTING FROM COLD WITH THE LIFEBOAT OUT OF THE WATER. PORT SIDE LIFEBOAT INOPERABLE, SELF-REPORTED PRIOR TO ARRIVAL, STICKING FUEL RACK AND BAD F/O FILTER FOUND BY TECH REP.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 March 2023
Resolved 14 March 2023
Resolution: Fuel pump renewed, filter changed, and successful operational testing to the satisfaction of Flag, Class and USCG.
07 - Fire Safety › N/A - No Subsystem › Emergency Escape Breathing Device and disposition
Issued 11 March 2023 Resolved
EMERGENCY ESCAPE BREAKTHING DEVICES SHALL COMPLY WITH FIRE SAFETY SYSTEMS CODE. THE EEBD SHALL HAVE A SERVICE DURATION OF AT LEAST 10 MINUTES. PSCO OBSERVED 01 EEBD IN THE PUMP ROOM TO BE OUTSIDE THE 10 MIN SERVICE DURATION.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 11 March 2023
Resolved 11 March 2023
Resolution: Vessel replaced deficient EEBD with a spare.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 March 2023 Resolved
IN TANKERS, ELECTRICAL QUIPMENT, CABLES AND WIRING SHALL NOT BE INSTALLED IN HAZARDOUS LOCATIONS UNLESS IT CONFORMS WITH STANDARDS NOT INFERIOR TO THOSE ACCEPTABLE TO THE ORGANIZATION. PSCO FOUND GROUND WIRES MISSING ON EXPLOSION PROOF FIXTURES INSIDE THE CARGO PUMP ROOM. PSCO ALSO FOUND MULTIPLE CRACKED LENSES ON EXPLOSION PROOF FIXTURES INSIDE THE CARGO PUMP ROOM.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 March 2023
Resolved 14 March 2023
Resolution: Ground wires fitted, and cracked explosion proof lenses replaced to the satisfaction of Flag, Class and USCG.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.