MAURY USCG vessel records
← All vessels

MSC LEANDRA V

MSC LEANDRA V is a 2007 freight ship. The Coast Guard has recorded 7 inspections since 2023, most recently in January 2025, along with 2 deficiencies.

Records from 2023 to 2025. Most recent: inspection, 31 January 2025.

Built
2007
Last inspected
31 January 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9313943
917961
Flag
PORTUGAL
Maury page id
psix-917961

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspections, by type

Years with a record 3 calendar years (2023–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it76202 - Displacement, Ton
53519 - Dead Weight, Ton
48853 - Simplified, Gross Ton
16832 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 7

31 January 2025 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8072448
7 August 2024 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7976342
29 July 2024 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7969408
14 November 2023 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7824519
2 August 2023 Ballast Water Examination · PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7758886
26 July 2023 PSC C
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7753117
25 July 2023 PSC B · Ballast Water Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7750940

Deficiency record · 2

07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 July 2023 Resolved
Fixed local application fire-extinguishing systems are to protect areas such as the purifiers for heated fuel oil. 03 sprinklers of the fixed water mist system in the purifier room were inoperable.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 July 2023
Resolution: Vessel personnel conducted maintenance on affected sprinklers and USCG witnessed satisfactory operational test.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 25 July 2023 Resolved
Machinery systems and fittings shall be of a design and contruction adequate for the service for which they are intended and shall be installed to reduce to a minimum any dangers to a person on board. 04 guard rails found cut and 02 guard rails missing in main machinery space.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 5 September 2023
Resolution: Vessel was able to provide LR Class surveyors report attesting to the satisfactory repair of the railings in the Main Machinery Space. Deficiency cleared.

Ownership record